Showing results: 2611 - 2625 of 3432 items found.
-
777754-01 -
NI
16-Channel, 7 A, SPST PXI Relay Module—The PXI‑2565 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. It delivers high-current switching of DC power supplies, AC line power, and AC/DC current sources. The PXI‑2565 is fully software programmable and supports multiple instrument synchronization.
-
778473-02 -
NI
The USB‑232/2 interface transforms your USB port into a single asynchronous serial port for communication with RS232 devices. You can use a USB‑232/2 port as a standard serial port from your application, including RTS/CTS hardware handshake lines. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
777796-01 -
NI
16-Bit, 32-Channel, Static PXI Analog Output Module—The PXI‑6704 is a static analog output device. You can use the PXI‑6704 to create software-timed voltage and current output applications. You can independently set the output voltage range on each channel. The PXI‑6704 also includes eight 5 V TTL/CMOS digital I/O lines.
-
778572-43 -
NI
6.6 GHz, 50 Ω, Solid-State, Dual 4x1 PXI RF Multiplexer Switch Module—The PXI‑2543 features high-performance solid-state relays that offer unique benefits such as unlimited relay life and fast switching time. Front-mounted SMA connectors provide easy connection to your RF devices, and the module features termination on every COM line and channel.
-
778572-44 -
NI
6.6 GHz, 50 Ω, Solid-State, 8x1 PXI RF Multiplexer Switch Module—The PXI‑2544 features high-performance solid-state relays that offer unique benefits such as unlimited relay life and fast switching time. Front-mounted SMA connectors provide easy connection to your RF devices, and the module features termination on every COM line and channel.
-
778473-04 -
NI
The USB‑232/4 interface transforms your USB port into a single asynchronous serial port for communication with RS232 devices. You can use a USB‑232/4 port as a standard serial port from your application, including RTS/CTS hardware handshake lines. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
778472-01 -
NI
The USB‑232 interface transforms your USB port into a single asynchronous serial port for communication with RS232 devices. You can use a USB‑232 port as a standard serial port from your application, including RTS/CTS hardware handshake lines. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
FWBELL 4000 series -
Integrity Design and Reseach Corp.
Typical Applications include checking the 50 and 60 Hz magnetic fields (EMF) produced by equipments such as AC Power Lines, Office Equipment, Video Display Terminals, Household Appliances, home and Building Inspection, etc.. Magnetic fields are invisible radiations, the best method to measure the strength fields is to use one of the accurate gauss meters offer by Integrity Design & Research corp.
-
4100 Series -
Integrity Design and Reseach Corp.
Typical Applications include checking the 50 and 60 Hz magnetic fields (EMF) produced by equipments such as AC Power Lines, Office Equipment, Video Display Terminals, Household Appliances, home and Building Inspection, etc.. Magnetic fields are invisible radiations, the best method to measure the strength fields is to use one of the accurate gauss meters offer by Integrity Design & Research corp.
-
IDR-210 -
Integrity Design and Reseach Corp.
Typical Applications include checking the frequencies and magnetic fields (BW: 20-4000 Hz) produced by equipments such as computer monitors, television sets, power lines, induction heaters, industrial, scientific and medical equipment and household appliances, etc. Magnetic fields are invisible radiations, the best method to detect them is by using one of the accurate gaussmeter from Integrity Design & Research Corp.
-
Intepro Systems
The Intepro’s battery test systems are configurable systems designed to test the latest Lithium Ion batteries and other high power density batteries and chargers. Combining high resolution, high powered charge and discharge systems, Intepro IBT line of battery test systems link to the battery management through the bus communication and fail-safe external monitoring of key battery parameters.
-
Advanced Energy
Advanced Energy is a trusted high voltage power supply provider with over 40+ years of experience. Our extensive line of Trek high voltage amplifiers offer numerous voltage and current ranges to accommodate your demanding applications. Protect against output short circuits and over-voltages. For protective shutdown, utilize automatic crossover compliance limits or current trip features.
-
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
Hilkar
Shunt Reactors act as absorbers of reactive power to increase energy efficiency of the power system. Shunt Reactors are inductors that are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. The shunt reactors provide inductive compensation.
-
Kast Eng Co. LTD.
All electric equipments & systems is required Impulse Simulation Test to the to be tested under the condition where the power source is applied to the product-under-test.At this test condition, the decoupler is needed to reduce the impulse flowing through the power line while testing. And the coupler which is inserted between tester and product, to simulate the actual condition, so the electric circuit of decoupler is prescribet by IEC rules.