  • Surge Generators

    Hybrid - Hilo Test

    Surge pulses occur due to direct or indirect lightning strikes in a circuit or by switching transients caused by switching inductive loads or short circuits. This leads to currents or electromagnetic fields causing high voltage or current transients. Surge voltages and currents can reach several thousands of volts and thousands of amperes. Our following Surge generators simulate these disturbances for all the necessary level in accordance with IEC / EN 61000-4-5 and IEC / EN 60060.

  • RS-232 to RS-422 Interface Converter

    Model 253 - Telebyte, Inc.

    FEATURES: DB9 Data Port; Compatible with PC/386/486; Full Duplex; Surge Protection. Adding an RS-422 interface to a PC is now a snap. The Model 253 Interface Converter does this for full duplex signals at data rates up to 19.2 KBPS, without requiring any AC or DC power. With only TD, RD and ground, the Model 253 provides operation over 8,000 feet of twisted pair into a load of 120 Ohms.

  • Energy Meter Terminal

    Zhengzhou SMS Electric Co.,Ltd

    Meter reading terminal is such an advanced technology product, with the functions of data-collecting, processing and saving, remote meter reading, remote maintenance and software upgrade. It adopts high-performance 32 bits (ARM 9 series)CPU and Linux real-time operating system, having the characteristics of advanced design, high reliability, high compatibility, stable operation and complete functions. It is the best choice for power formula meter reading automatically, data statistics and load management.

  • voltage controlled crystal oscillator

    VCXO - Epson Toyocom

    A VCXO (Voltage Controlled Crystal Oscillator) is a crystal oscillator the output frequency of which is controlled by adding an external control voltage via a frequency control input on a variable capacitance component such as a varactor diode connected in parallel to a load capacitance (CL). Epson VCXOs are divided into two types according to Voltage-Frequency (V-F) characteristic slopes depending on the AFC (Automatic Frequency Control) input configuration of the VCXO. One is a VCXO with a positive V-F slope and the other is a VCXO with a negative V-F slope. Please note that the input voltage of a control circuit will vary according to the individual type, as shown in Figs. 3 and 4. Epson's VCXOs are capable of either, depending on the customer's preference. Epson's VCXOs have been increasingly used for broader applications such as slave oscillators in phased-lock loops, or frequency modulators. Among the above types, a VCXO combined with a TCXO is called a VC-TCXO , respectively. These components have the merit of delicately controlling their output frequency electrically.

  • Agriculture Solutions

    Klingelnberg ag

    The trend in agriculture: The drives of machines and commercial vehicles must be capable of transmitting increasingly high power within a limited space. Reproducible quality in series manufacture with the shortest possible production times are the key requirements in this industry.The hay makers and harvesters perform their task using straight bevel gears. Because the loads in these machines are comparatively small, a cost-effective manufacturing solution is crucial for the market success of straight bevel gears. It’s a different story as far as tractors are concerned: Spiral bevel gears are installed in the rear axles in this case – and the bevel gear set of a tractor’s rear-axle differential must transmit up to 400 kW. In tractors, cylindrical and planetary gears are also used in manual transmissions and counter shaft transmissions as well as planetary gear drives for transmitting power to the enormous drive wheels. These cylindrical and planetary gears must be efficient, quiet-running, and low-maintenance. With solutions from Klingelnberg, the entire portfolio can be produced on bevel-gear and cylindrical-gear machines.

  • Data Migration Testing

    TestingXperts

    Development of a Data Warehouse is a major task which is expected to yield major business benefits in respect to the justification of the cost & efforts. However, many ETL projects fail to achieve the required benefits due to improper quality assurance strategy. ETL or Data Migration Testing should ensure that the data migrated from heterogeneous sources to the data warehouse occurs without any loss of information/ data, with strict adherence to transfer rules & in compliance with validity checks. ETL Testing should be able to detect early on any problems with the source data if done effectively, any other inconsistencies or ambiguities required to guide data transformation & integration should also be detected during the early stages of ETL Testing. ETL testing should be continuous to ensure that the extraction, transformation, and load processes are working as planned and the result is consistent, accurate, and complete. We are the leading Data Migration testing company offering quality testing services to our clients.

  • 50Hz-100kHz LCR Meter

    11022/11025 - Chroma Systems Solutions, Inc.

    0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver

  • Battery Capacity Tester

    BLU-T Series - IBEKO Power AB

    Battery load bank BLU-T is a powerful and lightweight solution designed for condition assessment of telecommunication and radio equipment backup supply. This instrument can perform the battery capacity test on battery strings such as Pb, Li-ion, Ni-Cd, and others. It tests battery strings with voltages in the range of 0,9 – 70,5 V DC. As a special feature, the BLU110T model enables capacity testing of single PB, Ni-based as well as Li cells (with current up to 100 A).The capacity test is conducted in an accurate, user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU-T battery load bank enables setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, the BLU-T units can be connected in parallel, or BXL-T additional load units can be linked.The instrument offers a high power-to-weight ratio. BLU-T series has models starting from 12,8 kg / 28.2 lbs and up to 19,2 kW of power.A user can select one of three discharge modes: Constant current, Constant power, Constant resistance. Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.Discharge parameters can be monitored in real-time during the capacity test. A 4,3-inch touch screen shows overall battery voltage, discharge current, discharge test time and capacity during the entire test. Also, the capacity tester is compatible with DV-B Win software. A user can view a detailed numerical and graphical presentation of key parameters, and create reports in various formats.Testing can be carried out without disconnecting the battery from the service.

  • Test Bench for Starters and Alternators

    MS002 COM - MSG Equipment

    A high power multifunctional test bench includes the following diagnostic functions: diagnostics of starters, alternators and voltage regulators without applying any additional measuring devices. The test bench was invented on the basis of the requirements of modern service stations: construction implies mounting of majority of units without using additional fixing elements. The bench tests units of 12V and 24V; diagnoses the latest alternators and voltage regulators, which are controlled by car ECU; has ports to connect alternators of different brands and manufacturers: COM (LIN, BSS), P-D, DFM, D+, RLO, C, SIG. Diagnostics is carried out through load simulation of car consumers, change of rotation speed, sending of control signals (external control alternators), tracking of electrical characteristic. Testing results are transmitted to LCD display real-time. Testing modes are switched with membrane keyboard on the control panel of the test bench. The selected mode is lightened with the corresponding indicator.The equipment carries out testing of different alternators under load up to 200A. Power supply is single-phase 380V.

  • PXI Strain/Bridge Input Module

    NI

    PXI Strain/Bridge Input Modules feature up to eightchannels that support quarter-, half-, or full-bridge sensors at speeds up to 102.4kS/s. The modules provide increased accuracy, high data throughput, and a range of synchronization features. Optional features include remote sensing, internal bridge completion, and shunt calibration options per channel. PXI Strain/Bridge Input Modules are ideal for dynamic strain, load and pressure measurements, and test cell installations requiring accuracy and flexibility.

  • Power Functional Test with Energy Saving Solutions

    Power System - SEICA SpA

    The Power System is a test platform conceived to verify and certify the operation of power modules.The complete structure, combining two Multi standard cabinets, is sized to contain all of the resources required for testing: drive/sense modules, power modules and load simulators.In this tester, in addition to strictly perform the requested measurement as per technical specifications, the issues of consumptions and dissipations were taken into account, integrating an Energy Recovery circuit which enables reuse of output energy to supply the system.

  • Mini-Test Station

    Fuel Cell Technologies, Inc

    Mini-Test Station for low current fuel cell testing. The test station includes Analog mass flow controllers for Anode and Cathode gas streams, humidity bottles with preheaters and temperature controllers and a cell temperature controller. The test station is designed to use the customer's Potentiostat to load the cell. Manual backpressure is provided for pressures from 0-60 psig. The Mini-Test station is basically our Analog Mass Flow Controlled Low Flow Humidification System with all the options.

  • FC Impedance Meters

    Kikusui Electronics Corp.

    designed for testing of the fuel cell with the small current (5 A or less), and not only the current-voltage characteristic test, the KFM2005 can easily measure for the impedance of a fuel cell using the AC impedance method, and the Cole-Cole plot. Using the measurement data of the Cole-cole plot, it is possible to calculate the circuit constant of the approximate equivalent circuit of the fuel cell. The built-in DC load (60W) is capable to operate from 0 V, and it can perform the test for the fuel cell up to 20V and 5A.

  • Shunt Voltage References

    Analog Devices Inc.

    Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.

  • Bench top Dielectric Withstand tester

    HYPOT III - Wavecontrol, S.L.

    RS-232 Interface available for automated controlPatented SmartGFI® functionPatented CAL-ALERT® functionComes complete with a test box for products terminated in a line cordPatented VERI-CHEK® functionStorage of up to 10 setups with 3 steps per setupBuilt-in security settingsDigitally controlled arc detection systemNo load setup of trip current and output voltageElectronic ramping (up & down)Built-in adjustable continuity testInterconnection to HYAMP® III to form complete test system