Filter Results By:

Products

Applications

Manufacturers

Showing results: 421 - 435 of 659 items found.

  • Microwave Wideband Synthesizer w/ Integrated VCO

    ADF5356 - Analog Devices Inc.

    The ADF5356 allows implementation of fractional-N or integer-N phase-locked loop (PLL) frequency synthesizers when used with an external loop filter and an external reference frequency. The wideband microwave VCO design permits frequency operation from 6.8 GHz to 13.6 GHz at one radio frequency (RF) output. A series of frequency dividers at another frequency output permits operation from 53.125 MHz to 6800 MHz. The ADF5356 has an integrated VCO with a fundamental output frequency ranging from 3400 MHz to 6800 MHz. In addition, the VCO frequency is connected to divide by 1, 2, 4, 8, 16, 32, or 64 circuits that allow the user to generate RF output frequencies as low as 53.125 MHz. For applications that require isolation, the RF output stage can be muted. The mute function is both pin- and software-controllable.

  • Hydraulic Component Test Stand

    Model 700 - Power Test, Inc.

    Model 700 Hydraulic Component Test Stand (HCTS). Designed to test heavy-duty, off-highway, closed or open loop pumps, the 700 gives you the capacity to confidently and efficiently verify the quality of your work. Test new or rebuilt pumps, motors, valves, and cylinders independently, and communicate their quality to your customers with the help of PowerNet TD, data acquisition software for transmission and hydraulic systems. Convenient work height with adjustable mounting track. 100, 200 or 300 HP drive motor options available. Variable Frequency Drive (VFD) controlled drive motor. 200 gallon (757 L) high-mount hydraulic oil reservoir for flooded pump supply. Combined kidney filtration and cooling loop for continuous cleaning. Thermostatically controlled cooler and 7 kW reservoir immersion heater.

  • Carrier to Noise Generators

    CNG-DX - Hollis Electronics Company LLC

    CNG-DX provides improved noise generation with its internal digital power meter and built-in noise generator. This single instrument provides accurate and repetitive carrier-to-noise setting ability in one box. The CNG-DX is an ideal instrument for creating realistic scenarios for closed loop testing of satellites, ground equipment and mobile transceivers.

  • High Current Transformers

    Hilkar

    High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.

  • Material Science Laboratory Instruments

    Mittal Enterprises

    our material science laboratory instruments basically consists of four instruments first, young modulus apparatus which is used for determining the young modulus elasticity of a wire by stretching it. Then second is curie temperature kit which is used for determining the Curie Temperature. With the determination of dielectric constant of PZT material with Temperature variation. After that comes dielectric constant kit which is used for measuring the dielectric constant of solids and lastly our universal B-H Curve Tracer which is used for tracing the B-H loop which is very difficult and needs a good machinery for doing so.

  • Sanitary Magnostrictive Level Transmitter

    DM330S - AMETEK Drexelbrook

    The Drexelbrook DM330S is a sanitary magnetostrictive level transmitter providing Triclover fittings as standard mountings. It is authorized by 3A Sanitary Standards Council for level applications in the food and beverage industries.The DM330S takes field proven sensing technology and incorporates intrinsic safety with a field programmable zero and span.The two wire loop powered level transmitter is configurable with a 4-20 mA span and is not affected by changes in electrical characteristics.It uses proven machine tool positioning accuracy combined with a process compatible float to offer a liquid level, and interface measurement system for the process industry.

  • Motorized Polarization Scrambler

    UC8340 - UC Instruments, Corp.

    The UC INSTRUMENTS UC8340 Motorized Polarization Scrambler is a program motorized control polarzation scrambler. Its polorization controlled capability enhances measurement speed, accuracy, and overall productivity. The continuous length of fiber enables high power and ultra-low insertion loss. This design offers a wide range of AutoScan rates and high incremental angular resolution. Four fiber knob loop design has proven to provide excellent control with ultra-low power variations(PDL). This reliable design allows for a wide range of applications from component testing to PMD related activities.

  • Battery Charge And Discharge Test System

    9841 - PRODIGIT Electronics Co, Ltd.

    *Easy user interface*Measure Voltage, Current, Power, KWH, AH, Temperature, Reference Voltage*Accuracy Measure Time*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery. *The test result will be stored to ACCESS data

  • Industrial Water Chiller

    Wewon Environmental Chambers Co, Ltd.

    The industrial chiller is a kind of cooling water equipment which can provide constant temperature, constant water flow speed and water pressure. Industrial process chiller is usually a closed loop system, which can provide instantaneous cooling for the factory or lab production process and save water by recirculating cooling.Industrial chiller system be divided to low temperature chiller and normal temperature chiller in the temperature control. The normal temp is generally controlled within the range of +4 ℃ to +35 ℃. The low temperature water chiller is generally controlled in the range of 0 ℃ to -100 ℃.https://www.wewontech.com/industrial-chiller/

  • Temperature Transmitters

    Rotronic Measurement Solutions

    A temperature transmitter is an electrical instrument that interfaces a temperature sensor (e.g. thermocouple, RTD, or thermistor) to a measurement or control device (e.g. PLC, DCS, PC, loop controller, data logger, display, recorder, etc.). Typically, temperature transmitters isolate, amplify, filter noise, linearize, and convert the input signal from the sensor then send (transmit) a standardized output signal to the control device. Common electrical output signals used in manufacturing plants are 4-20mA or 0-10V DC ranges. For example, 4mA could represent 0°C and 20mA means 100°C.

  • Relative Humidity & Air Temperature

    A70-HT - Comptus

    The A70-HT provides analog output signals proportional to relative humidity and air temperature. The A70-LPDD loop indicator can be used to display the sensed relative humidity and temperature with the 4-20 mA output. These units are used in conjunction with electronic data collection systems or for input to control systems. They are readily combined with meter relays to provide custom controls.

  • Temperature Transmitter

    T4111 - COMET SYSTEM, s.r.o.

    Transducer is designed for temperature measurement at C or F by means of an externaltemperature probe with Pt1000 sensor. Measured temperature is converted to linearized unified signal 4-20 mA. Measured values are displayed on LCD display. It is possible to switch OFF theLCD at all. Current loop has two-wire connection and requires power from evaluation device.

  • Dual High Speed Power Supply

    VX4620 - VX Instruments GmbH

    Dual high speed power supplyLow noise linear output stage with 200 Vpp and 1 AProgrammable bipolar voltage and positive/negative current limitsStable control loop even on long load linesAuto sensing featureProgrammable slew rateProgrammable over GPIB, USB or RS232Fast rise and fall times due to integrated sink capability

  • Board to Board Interconnect

    R&D Interconnect Solutions

    Highly Configurable – Custom Pad/ Array Configurations Available•Mixed Digital, Power, RF on Same Array•Double the Compliance of a Single Pin•Air Dielectric Option for Hi-Speed/ RF•Unparalleled Performance!•< 1 dB loss @ 65GHz•Up to 4 Amps continuous•Ultra-Low Loop Inductance•Environmental -40°C to +150°C

  • AC Hysteresis Graph Test System

    DX-2012SA - Dexing Magnet Tech. Co., Ltd

    Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.

Get Help