Filter Results By:
Products
Applications
Manufacturers
- TEAM SOLUTIONS, INC.
product
4-Port Serial Interface, Modular, With/Without Optical Isolation, 3.3V
CPCI-7500
*This Model has a 37-pin D-Sub male connector*RS232, RS422, RS485, 20 mA Current Loop*Modular structure through SI modules*With or without optical isolation*Mode configuration free for each port*128-byte FIFO-buffer, common interrupt*Transfer rate programmable up to 115,200 Baud*Option: up to 1 MBaud for RS485 and RS422*Automatic direction recognition for RS48*Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)*Transmission mode asynchronous, full, half duplex*Transfer rate: progr. up to 115.2 kBaud up to 1 MBaud on request*Protocol: 5, 6, 7 or 8-bit character 1, 1? or 2 stop bits*Parity: even, odd, none, mark or space*Interrupt lines: automatic through BIOS
-
product
100-Watt DC Power Line Conditioner w/Holdup
44LS1
NAI’s 44LS1 is a 100-Watt Power Line Conditioner with holdup time that protects downstream DC/DC converters from transients, low voltage conditions, and power interruptions. This unit accepts +28 VDC input and provides 22.5 to 30 VDC at 100 Watts to all downstream DC/DC converters.
-
product
500 Watt AC/DC Power Line Conditioner, 3U VPX, Holdup Time
VPX56-3HU
NAI's VPX56-3HU is a rugged, high-performance 500-Watt Output +28 VDC Input 3U VPX AC/DC Power Line Conditioner designed for aerospace, defense, and industrial markets. This off-the-shelf power supply plugs directly into a standard VPX conduction cooled chassis and protects downstream DC-DC converters from MIL-STD-704 transients, low-voltage conditions and power interruptions, providing up to 50 milliseconds of holdup time at up to 500-Watts. Continuous Background Built-In-Test (BIT) and I2C communication are included.
-
product
CHANCE Teleheight Tool
This handy little instrument helps to figure quickly and accurately the heights of poles, trees, buildings or conductor clearance. A lineman can be taught in a few minutes to use it. The diagram at left shows how it works. Sight point A through the Teleheight and move backward or forward until the bubble centers on the hair line, which will be point C. Measure distance from C to D and add distance BC to find correct height. Leather case (21?4" x 41?4") had belt loop.
-
product
Counter/Timer Board
MSXB 036
The MSXB 036 Counter/Timer Board is used for frequency counting, rotational speed (tachometer) measurement, and closed loop process control based on frequency criteria. Engine performance monitoring is a typical application. The Counter/Timer Board provides 16 digital input lines and 16 digital output lines, counts up to 6 MHz on 10 channels, and has two 100 MHz frequency prescalers.
-
product
Data Logging
The LogTxt macro can be used together with a timer macro in a loop to produce a data log that consists of a timed series of data samples. Each line in the file can be anything you want, typically a time-stamp (including date, if desired) plus one or more values recorded at that time. The interval between samples can typically be from less than a tenth of a second, up to hours or days... or even longer.
-
product
Event Detectors
105/106 Series
The 105/106 Series Event Detectors are the most versatile Event Detectors in the product line. These Event Detectors monitor the electrical resistance of up to 128 simple continuity loops, each comprised of single or multiple specimens under test. Each test specimen is continuously monitored while a selectable DC sense current is passed through each channel test-loop; resistance changes exceeding the selected threshold are recorded as an event. Minimum Event Duration, Channel Current, and Threshold Voltage settings can all be independently configured. 105 and 106 Series instruments are electrically identical, with the difference simply that the 105 offers four, 32-channel board slots and the 106 offers only one. Thus the 128-105 is equivalent to four 32-106 Event Detectors.
-
product
Linear regulated power supply with thyristor pre-regulation
NTN
High efficiency Short circuit proof and unlimited operation with full current in short circuit condition voltage and current regulation with automatic and sharp transition; control mode indicated by LEDs Voltage and current setting with 10-turn potentiometers with precision scale; the adjusting knob can be locked 4 digit DVM for voltage and current (for table-top models) Sense terminals for the compensation of voltage drop on the load lines. The nominal voltage always refers to the output terminals Parallel and series connection possible Suitable for inductive and capacitive loads for 700 W nominal power and higher, limitation of inrush current on switching on Interlock loop to monitor the external load and internal loop as a standard for three phase units Elapsed-hour meter as a standard for three phase units
-
product
Loop A Line
TX916
The Loop a Line has been a Telstra standard for 20 years. It is probably the simplest time saving device available for contractors and technicians. Once fitted to the far end of a line you can switch between Open, Short, Connect, 600 ohm, and Tone modes allowing all installation and fault location to be performed from the one end without having to go back and forward from one end of the line to the other.
-
product
Loop and Line Powered Level Switch
Safety IntelliPoint
The Safety IntelliPoint level switch provides a capacitance probe level switch with either a current output or relay contacts and “On-Board” self-diagnostics to ensure reliability. This SIL Intellipoint conforms to SIL 2 specifications providing the ultimate in level switch integrity and level sensing elements for a wide variety of temperatures, pressures, and materials.
-
product
Power Conversion
The XRP6124 is a non synchronous step down (buck) controller for up to 5A point of loads. A wide 3V to 30V input voltage range allows for single supply operations from industry standard 3.3V, 5V, 12V and 24V power rails. With a proprietary Constant On-Time (COT) control scheme, the XRP6124 provides extremely fast line and load transient response while the operating frequency remains nearly constant. It requires no loop compensation hence simplifying circuit implementation and reducing overall component count. The XRP6124 also implements an emulated ESR circuitry allowing usage of ceramic output capacitors and insuring stable operations without the use of extra external components.
-
product
Telephone Line Simulator
TLS-5
The TLS-5 Telephone Line Simulator offers the most convenient way to demonstrate or test telecom equipment where central office lines are not easily available. The TLS-5 functions as a virtual CO switch, providing four simulated central office lines with two talk paths, plus an audio interface port. Features include: 4 loop start lines, 2 talk paths, PBX features, programmable parameters, precise call progress tones, caller ID features, CLASS features, and programmable dial tones.
-
product
4-Port Serial Interface
APCI-7500-3
This Model has a 37-pin D-Sub male connectorRS232, RS422, RS485, 20 mA Current LoopModular structure through SI modulesWith or without optical isolationMode configuration free for each port128-byte FIFO-buffer, common interruptTransfer rate programmable up to 115,200 BaudOption: up to 1 MBaud for RS485 and RS422Automatic direction recognition for RS48Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)Transmission mode asynchronous, full, half duplexTransfer rate: progr. up to 115.2 kBaud up to 1 MBaud on requestProtocol: 5, 6, 7 or 8-bit character 1, 1? or 2 stop bitsParity: even, odd, none, mark or spaceInterrupt lines: automatic through BIOS
-
product
ACDC
EC Series
The EC Series of line operated power supplies features near constant efficiency over theentire rated input voltage range. These electrically identical families employ a highly efficient, closed loop ripple regulation circuit, which contains a low pass filter. Each stage, transformer, filter and regulator is engineered for maximum efficiency.
-
product
ACDC
ES Series
The ES Series of line operated power supplies features near constant efficiency over theentire rated input voltage range. These electrically identical families employ a highly efficient, closed loop ripple regulation circuit, which contains a low pass filter. Each stage, transformer, filter and regulator is engineered for maximum efficiency.
-
product
ACDC
EA Series
The EA Series of line operated power supplies features near constant efficiency over theentire rated input voltage range. These electrically identical families employ a highly efficient, closed loop ripple regulation circuit, which contains a low pass filter. Each stage, transformer, filter and regulator is engineered for maximum efficiency.
-
product
Alarms
Devar alarms are designed to accurately monitor process trip-points from current, millivolt, DC volts and thermocouple signals. These alarm points can be easily set in percent of signal or directly in engineering units. The units will constantly monitor the set point against the actual signal and switch a 10 amp SPDT relay when the set point is exceeded. Alarms are available in wall mount, panel mount, track or DIN rail mount, AC/DC line voltage powered or loop powered versions.
-
product
Telephone & Exchange Tester
ETT 10
Maintenance statistics of telephone networkshave shown that for most of the failures, theexchange - line - subscriber (EXCH-LINE-TEL) sections are responsible. Accordingly, the first step of the troubleshooting procedure is to locate the breakdown spot, i.e. to find out whether thefailure source is within the exchange, the subscriber site or in the line (local loop). Thisproblem can be easily solved by theTelephone & Exchange Tester ETT 10, in most cases without requiring the technician to visit the subscriber or the junction boxes along the line.
-
product
Compression Unit
BK1611
The BaKo BK1611 is a Compression Unit that uses a real time feedback loop to create a frequency sweep with constant level output. This would normally be used for either research or for calibration rather than product line testing and is useful because of its extreme stability. The BK1611 is not a dedicated system so it can be integrated into a variety of systems to be used for microphones, speakers or vibration motors.
-
product
CNC Vision Measuring Machines
SVM DCC Standard / Classic Series
*Professional and international origin brand name*Designed by professional development team, with style and structure in line with engineering engineering principles*Three axis CNC control system (fully closed loop servo control system) ensures the accurate positioning.*Modular design enables easy & convenient installation and maintenance.
-
product
Rotary Actuators
A line of of products that combine a high rigidity hollow rotary table with a closed loop stepper motor and driver package. It retains the ease of use of a stepper motor, while also allowing for highly accurate positioning of large inertia loads.
-
product
RCD Loop Line
Digital measuring instrument for RCD testing with Loop and Line resistance measurement also without tripping the RCD.
-
product
Digital Measuring Instrument
Z Loop Line
Digital measuring instrument for measuring of Loop and Line impendance.
-
product
Loop Resistance Measuring Device According to DIN EN 61557-3 (VDE 0413-3)
PeakTech Prüf- und Messtechnik GmbH
A loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
product
Loop / PFC Testers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2715 is a loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
product
Handsfree Telephone Communication Tester
TestPhone 850
The TestPhone 850 provides both handset and handsfree telephone communication. The product provides a standard Public Switched Telephone Networks (PSTN) interface, user interface and handset and/or handsfree vocal interface to allow the user to originate or answer standard PSTN calls on both Dual-tone Multi-frequency (DTMF - tone dialling) and Loop Disconnect (LD - pulse dialling) lines. In addition the product features on-hook audio line monitoring, PSTN line polarity indication, automatic on-hook/power-off and integral ADSL digital line filtering.
-
product
Public Switch Telephone Network Tester
295B
The Testphone 295B is a test telephone designed for use on Public Switched Telephone Networks (PSTN). It is designed for use on both Dual-tone Multi-frequency (DTMF - tone dialling) and Loop Disconnect (LD - pulse dialling) lines. Fitted with an integral ADSL filter, the telephone will not cause interference when connected to ADSL/Broadband lines in either `on hook` or `off hook` mode.
-
product
Line Loop Tester
8455
Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks.
-
product
32-CH 12-Bit 100 kS/s Isolated Analog Input Card
PCI-9113A
ADLINK PCI-9113A is a 32-CH, 12-bit, 100 kS/s isolated analog input card. The PCI-9113A provides analog inputs with 3 programmable input ranges for both bipolar and unipolar inputs. The 32-CH single-ended analog inputs can be converted to 16-CH differential analog inputs, which improve the noise rejection in harsh industrial environments. The analog inputs are isolated from the PC's system ground. This feature not only protects the PC from being damaged from surges on the signal lines, but also eliminates ground loops and common-mode problems commonly seen in industrial measurement applications. The PCI-9113A provides custom circuit area for input signal conditioning. Either signal attenuation or filtering can be applied on per channel basis. With all the features, ADLINK PCI-9113A delivers cost-effective and reliable data acquisition capabilities for ATE, sensor monitoring, data logging, power transmission, and a broad variety of industrial measurement applications.
-
product
Lightning Current Generator
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.