Filter Results By:
Products
Applications
Manufacturers
Loop backs
connect input to ouput to test I/O loop.
-
product
AC Power Sources, Frequency Converter
MAC-01, -02, -03
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
product
IndustryPack system trouble shooter
IP-DEBUG-IO II
IndustryPack system trouble shooter providing testpoints on all of the IP IO signals. Loop back is as easy as wire-wrap. Custom feedback signals are supported with socket and power connector support. Now with 2 ribbon cable connectors to support in system debugging.
-
product
Precision Current Loop Calibrator With Hart Communications
LC-110H
The Martel LC-110 and LC-110H are mA (loop) calibrators designed to take the loop calibrator class to the next level. The new LC-110 series feature a user friendly interface with dedicated buttons and a rotary encoder (Quick-Set Knob). This combination drastically reduces the time it takes to measure, simulate, or source both voltage and current and power up a loop. The rugged ABS plastic case is contoured to easily fit a technician's hand and the large back lit graphics LCD is best in class. The LC-110H differs from the standard LC-110 in that it incorporates HART communications and supports a select set of the HART universal and common practice commands. This unique feature allows the LC-110H to be used as both a loop calibrator and communication tool.
-
product
Transponder Panel with GNS/GTN Interface
TA-330XP
This transponder panel is layed out to accommodate thecurrent Mode S panel mount units. The transponder caninterface with a GNS or GTN series radio for a morecomplete test of the transponder functions. The panelalso includes altitude, suppression, loop back and thestandard ARINC 429/RS232 interfaces as well. The panelcomes with both a digital voltmeter and ammeter.
-
product
Mezzanine System
5041
ECM P/N 5041 provides eight channels of RS485 / RS422 I/O with fixed 120 ohm termination for each channel. Speeds are up to 30M bits per second. All channels power up as inputs. Also transceiver inputs are always enabled for loop back diagnostic use when the outputs are enabled. Software can enable outputs on a channel by channel basis.
-
product
Telemetry Simulators & Test Transmitters
Command Data Telemetry Simulators offer a dynamic way to create or change a PCM data stream on a word by word basis on the fly. This PCM data stream can be used to modulate an FM or SOQPSK RF output at S-Band or L-Band. In addition to simulating a new telemetry stream, the telemetry simulators can play back and loop an archived data file (which can also be changed on the fly) or create pseudo-random patterns.
-
product
Loop A Line
TX916
The Loop a Line has been a Telstra standard for 20 years. It is probably the simplest time saving device available for contractors and technicians. Once fitted to the far end of a line you can switch between Open, Short, Connect, 600 ohm, and Tone modes allowing all installation and fault location to be performed from the one end without having to go back and forward from one end of the line to the other.
-
product
One Core Loop Tester
DAMUL is an innovative and portable optical power checker accompanying 1-core loop back function. DAMUL can check SFP TX and RX power level by simply inserting SFP into it. If you use UPM (Universal SFP-typed Power checker Module) optionally provided, DAMUL can measure optical power. Also, when using SPM (SFP-typed Power checker Module) optionally provided, DAMUL can identify 18 CWDM wavelengths as well as its power automatically. DAMUL provide users high productivity for optical power checking work on fiber optic systems such as WDM-PON.
-
product
Main Effects
The Analog Multi FX is an Authentic Analog Multi Effects Pedal equipped with everything you need to get the job done on stage and in the studio. It’s got a Switchless Optical Wah, Distortion, Effects Loop, Stereo Chorus, and Echo. Even better these are reissues of classic Morley circuits leading all the back to the 1970’s. And speaking of the 70’s it also has a new finish that pays homage to the original chrome Morley pedals. It’s Heavy-Duty spun stainless steel that’s Built like a Tank and looks great under stage lights. Each one is hand spun at our Illinois facility.
-
product
Rain Test Chamber - Twin Shower
The Drive-In Rain Test Chamber is generally used to conduct whole body testing of assembled vehicles under different rain test procedures to study and estimate their structural degradations and destructions induced by rain/water. The twin shower area with 1.1 million litre & 0.35 million litre volume is enclosed in a shed where arrays of pipes are interconnected to form zones to ensure the uniform spraying as per JSS 55555 test standard. The water gushes through the nozzle at a flow rate of up to 288 cu m/hr and the test chamber water collection system have a central grating with sufficient slope to collect the sprayed water during operation and circulate it back to the water reservoir to ensure close loop circulation.
-
product
Wire Harness Tester
Panther4HT Master- Slave DSU
Qmax Test Technologies Pvt. Ltd.
The Master- Slave DSU based Panther4HT Wire Harness tester is designed for testing and verifying electrical connections in a cable, harness, backplane or any other wired assembly. It offers unique Qmax MASTER - Slave concept and SATELLITE UNIT Options to avoid looping back of cable to the ATE. All Satellite Units communicates the measurements through LAN interface which is very useful for on-board applications in Aircrafts / Ships and similar applications where large cable looms are used. This innovative concept will eliminate the long adapter cables and hence storing, maintaining and re work of these kind of cables are avoided. Furthermore single Master Controller Unit (MCU) is used to control not only all the satellite units , but also communicate with all satellite units through Ethernet Communication port. A single reference Cable is used to link the all the satellite units with the Master Controller in controlled loop manner is a value add to the product.