Showing results: 301 - 315 of 723 items found.
-
Thorlabs, Inc.
Thorlabs' Microwave Cables and Adapter Cables are flexible, high-performance, coaxial cable assemblies designed for use out to 50 GHz, depending on connector type (see the image to the right). The design gives these cables flexibility while maintaining optimal performance. They exhibit low VSWRs (Voltage Standing Wave Ratios) over the usable frequency range, as well as low insertion losses (see the Specs tab). These cables are each tested to ensure performance.
-
MFG-8202 -
MCH Instruments Co.,Ltd.
Features:• Low distortion, high stability• Linear and logarithmic sweep function• Sweep time and width adjustable• External Voltage Control Frequency (VCF)• Internal & external modulation (AM/FM) with modulation control• Output signal compatible with TTL/CMOS• Seven types of waveforms such as sine, square, triangle and ramp• 5W power output (ONLY for model no with “B”)• DC offset and 40bD attenuation can be applied to main output signal• Built-in frequency meter 0.1Hz~30MHz
-
MFG-8205 -
MCH Instruments Co.,Ltd.
Features:• Low distortion, high stability• Linear and logarithmic sweep function• Sweep time and width adjustable• External Voltage Control Frequency (VCF)• Internal & external modulation (AM/FM) with modulation control• Output signal compatible with TTL/CMOS• Seven types of waveforms such as sine, square, triangle and ramp• 5W power output (ONLY for model no with “B”)• DC offset and 40bD attenuation can be applied to main output signal• Built-in frequency meter 0.1Hz~30MHz
-
85024A -
Keysight Technologies
85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of resistance permits high frequency probing without adversely loading the circuit under test. Excellent frequency response and unity gain guarantee high accuracy in swept measurements with this probe. High probe sensitivity and low distortion levels allow measurements to be made while taking advantage of the full dynamic range of RF analyzers.
-
FC3000 Series -
ACECO Electronics Corp.
The latest advance in RF finder Frequency range: 10 MHz - 3 GHz Weight: 210g Case: 80 mm * 68 mm * 31 mm stamped aluminum with black anodized finish Battery: Internal 4 * AA 600 mAH NiCd pack 7 digit liquid Crystal Display with 1 KHz resolution Low power consumption (Average 6 hour battery life) Hold switch to lock display Digital filter prevents display of random noise Low battery indicator Ultra sensitive synchronous detector 16 section bargraph to show RF signal strength Automatically holds and tunes ICOM CI-V or AOR receivers Measure frequency and period
-
Greenlee Tools
*Measures AC+DC current*AC and AC+DC voltage measurements with digital low pass filter for accurate readings on variable frequency drives*Also measures DC voltage, resistance, capacitance and frequency*Tests continuity and diodes*Flashlight inside clamp jaw for easier work in dark locations*Backlight & relative mode for added versatility*Peak-RMS measures motor inrush current*AmpTip™ increases accuracy on small wires and low current*Two voltage detection modes - non-contact or using a single test lead*Data hold*Recording of Maximum, Minimum, and Average readings*Crest (peak hold) feature captures current or voltage peaks as short as 5 milliseconds
-
MDHC Series -
Smiths Interconnect
Smiths Interconnect's spring loaded High Frequency Micro-D Coax Connectors MDHC offer low VSWR of 1.5:1 (typical) up to 40GHz (max mated pair), maximum overall diameter of 0.125" fitted into low-profile micro-D housing, constant 50 Ohm airline impedance.
-
NKT Photonics A/S
Koheras single-frequency lasers are longitudinally single-mode and offer extremely low phase- and intensity noise levels. Available in the Erbium or Ytterbium wavelength ranges and with frequency conversion to many other bands.Reliability is our highest priority and the all-fiber DFB design ensures robust and reliable operation for thousands of hours.
-
Pulse Electronics
Pulse’s vast offering of high-performance cables and mounts across a range of applications will optimize your antenna installation. Our offering of low loss cable, high frequency NMO Mounts, and variety of connectors will make your antenna installation easier while preserving your antenna’s performance.
-
LPSU -
AWT Global
Low PIM coaxial switch matrix 5 x 6 or 1 x 4 configurationFrequency range 698-2700 MHz.SCPI commands via Ethernet (wired or wireless).Significantly reduces test time for multi frequency PIM applications.Applications: ATE systems, multi-band antenna and component testing.
-
MultiDimension Technology Co.,Ltd.
Are adaptive to installation height and tape width with excellent protection against magnetic material interference. Incorporating tunneling magnetoresistance (TMR) technique, the AGV-TMR15X series are designed to provide excellent temperature characteristics, good consistency, fast frequency response, high sensitivity and low power consumption performance.
-
James Instruments Inc.
Low frequency transducers for ultrasonic testing of concrete and other course grained materials. Shear Wave transducers (pictured above) are used in combination with compressional wave transducers to calculate Poisson's Ratio. The line of general-purpose compressional wave transducers feature robust PZT elements in stainless steel.
-
PP066 -
Teledyne LeCroy
The PP066 is a high-bandwidth passive probe designed for the use with the WaveMaster™ and other high-bandwidth oscilloscopes that have 50 Ω input termination. This very low capacitance probe provides an excellent solution for higher frequency applications, especially the probing of transmission lines with 20–100 Ω impedance.
-
Aarohi Embedded Systems Pvt. Ltd
*Pulse, frequency & isolated 4-20 mA output.*Empty pipe detection.*Online data can be transferred by using GSM modem.*Low maintenance.*Rate indicator , Totalizer & Batch function.*Easy installation & maintenance.*User friendly operating.*Computer interface measurement.*Linear & accurate measurement.
-
Schwarzbeck Mess Elektronik
The broadband horn antennas BBHA 9120 offer a very low SWR in their nominal frequency range and a very broad bandwidth. The gain increases with frequency up to approx. 21 dBi, depending on the horn's size and shape. The increasing gain with frequency helps to compensate cable losses. The BBHA 9120 series is suitable for both, transmission and receiving applications. The max. allowed Input Power is only limited by the female N-connector. The detailed manual of the calibrated test antennas includes Gain, Antenna Factor, SWR and Directional Patterns. The antenna is mounted with the 22 mm tube, equipped with a Index Ring for quick changes of polarisation without using tools.