Stefan Mayer Instruments
Hand-held instrument for precise measurement of weak magnetic field from 0.1 nT to 200 µT (DC to 1 kHz). Typical applications are: Measurement of the Earth's magnetic field vector components, detection of AC fields from power lines, paleomagnetic investigations, package inspection according to IATA 953, and residual field measurement.
-
-
-
DC Moving Coil Meter -
Bee Instruments
It uses magnetic deflection, where current passing through a coil placed in the magnetic field of a permanent magnet causes the coil to move.
-
RX - 213 -
Resonance Technology
Teslameter RX-213 is a portable, hall-effect magnetic field meter, measuring simultaneously - along three mutually perpendicular axes - both the DC component and the variable component of the field (AC) with a frequency of 20 Hz - 20 kHz. The latter quantity is measured as the effective value of the magnetic field (so-called true RMS ), regardless of changes in the field as a function of time.
-
Schwarzbeck Mess Elektronik
The magnetic, handheld coil was designed to generate defined mag-netic fieldstrength in the frequency range from DC up to 5 (7) MHz. The main application is immunity testing against magnetic fields.
-
MagCam NV
MagScope is Magcam's advanced data analysis software formeasuring and analyzing magnetic field distributions.MagScope is designed to extract as much informationas possible from the measurement data. MagScope is integrated in and optimized for all our magnetic field cameras and scanners.
-
Model KM 196 -
Kusam Electrical Industries Limited
• Unit : Electric Field : V/m; Magnetic Field : mT• Precision : Electric Field : 1V/m; Magnetic Field : 0.01 mT• Range : Electric Field : 1V/m ~ 1999V/m.• Magnetic Field : 0.01 mT ~ 19.99 mT• Alarm Threshold : Electric Field : 40V/m, Magnetic Field : 0.4 mT• Reading Display : 3½ Digit Digital LCD display with Backlight.• Frequency Range : 5Hz ~ 3500MHZ• Sampling Time : About 0.4 second.• Measuring Mode : Dual Mode• Overload Alert : “1” appears on LCD• Sound & Light Alarm• Data Hold function.• Auto Power Off.• Average & Peak measurement.• Low Battery Indication.• Operating Temperature & Humidity : 0°C ~ 50°C; below 80%RH.• Power battery : 9V Battery.• Dimension : 63.6 x 31 x 125.8mm• Weight : Approx. 146g.
-
IDR-800 -
Integrity Design and Reseach Corp.
Two cylindrical tubes are equal in length (12"), one is inside the other, both of them are closed at one end. At the other end, the inner tube is open (Radius=1").The cylindrical tubes are made from high permeability material.The magnetic field inside the inner tube is almost annulled.Optional use with the Geomagnetometer IDR-321 to provide a zero gauss (magnetic field-free environment) reference, enabling you to take absolute readings of the ambient magnetic field (the Earth's magnetic field is typically around 500 mG)
-
Cryogenic Ltd.
Cryogenic vector magnet systems allow precise alignment of the magnetic field to an exact direction in a measurement sample. The system provides the capability of orienting the magnetic field to any vector direction. This is suitable for experiments where samples cannot be moved easily.
-
MRC ltd.
This meter is used to indicate radiated electromagnetic fields. Wherever there is a voltageor a current, electric (E) and magnetic (H) fields arise.
-
Oersted Technology
A conditioner is a device that is used to selectively adjust the magnetic strength of a part to a specified value. In the past, conditioners have been used to simply “knock-down” the magnetic field of low-coercivity magnet parts (such as alnico and ferrite) until a certain field level was achieved. The resulting part was slightly weaker, but had a field strength that was repeatable.
-
Oersted Technology
A conditioner is a device that is used to selectively adjust the magnetic strength of a part to a specified value. In the past, conditioners have been used to simply “knock-down” the magnetic field of low-coercivity magnet parts (such as alnico and ferrite) until a certain field level was achieved. The resulting part was slightly weaker, but had a field strength that was repeatable.
-
C 510 -
Dr. Brockhaus Messtechnik GmbH & Co. KG
The sample is exposed to a defined magnetic field within a measuring coil. A magnetic flux is created inside the material. The required current is supplied by a power amplifier.
-
OHT Inc.
*This system can measure MRAM characteristics automatically.*Generates strong and constant magnetic fields. (Max 1.5T, the highest in the industry)*Performs high speed sweep of magnetic field by using non-magnetic materials wafer chuck. (Max 4Hz, ±1T, the highest in the industry)