Showing results: 1 - 15 of 47 items found.
-
-
ROTOMAT / TRANSOMAT Product Family -
Foerster Instruments, Incorporated
With the new generation ROTOMAT DA and TRANSOMAT DA flux leakage test systems FOERSTER is setting new standards in continuous quality assurance of ferromagnetic steel tubes. The test systems enable the reliable detection of natural and oblique defects, regardless of their angle or length, in addition to standardized longitudinal and transversal defects. The miniaturization of sensors together with highly integrated electronic components dramatically increases the number of channels. This makes a more precise and finer scan of the surface possible, giving a more complete set of information regarding detected defects. The newly introduced C-Scan visualizes these defects in high-definition and real-time, resulting in a completely new evaluation of the tubes to meet rising quality requirements.
-
ROTOFLUX® Multichannel MFL -
Magnetic Analysis Corp
MAC’s Rotoflux® Multiplex Electronics—Magnetic Flux Leakage testing that provides superior technology, performance and versatility.
-
Rinch Industrial Co.,Limited
Digital Fluxmeter is instrument made by electronic integration principle and displays the magnetic flux digitally. It can test magnetic materials. It not only measures flux but also directly tests magnetic performance for the purpose of quality control. With the features of legible display and convenient operation, it is an ideal device for flux measurement.
-
CWM -
TOEI INDUSTRY CO, LTD.
The automatic measurement equipment to continuously measure magnetic property in commercial power frequency of magnetic steel sheet sample on line, is used for quality control. Core loss in definite time of magnetic flux density [B] or magnetic flux density [B] in definite time of strength of magnetic field [H] for excited magnetic steel sheet is measured on line.
-
Star Trace (P) Ltd.
Star Trace Pvt. Ltd. is a renowned manufacturer and supplier of unbeatable quality Magnetic Field Flux Meters. The company manufactures these Magnetic Flux Meters from top-grade raw materials to ensure quality and performance. In order to ensure customers' satisfaction, these Magnetic Flux Meters are sent for several stringent quality control tests before supplying and exporting them to customers.
-
Ferrites India
Flux meter has been the established standard for the measurement of magnetic flux density for determining total flux in a magnet or magnetic assembly. Its use was curtailed except in a few specialized areas because of many factors such as the difficulty in setting up light beam flux meter or ballistic galvanometers, limitations on the ohmic resistance of search coils, the requirement of some degree of operator skill in reading the flux meter etc. The development of the integrating type Digital Flux meter has virtually cancelled the hitherto negative aspects of fluxmeterology and has found a broad niche for many magnetic measurement applications.
-
MAGNET-PHYSIK Dr. Steingroever GmbH
The measurement of magnetic quantities can almost always be attributed to the measurement of a magnetic flux. Therefore, the magnetic flux meter, the flux meter, is the most versatile meter in magnet technology. The fluxmeter is operated together with a measuring coil. Measuring coils for various applications are available: field coils (ie, point coils and thin-film coils), moment coils (Helmholtz coils), potential coils, saturation coils, etc.
-
Iris Power LP
Rotor magnetic flux variations are the result of the degradation of the rotor winding insulation by mechanisms like load cycling, thermal aging and contamination. Iris Power provides solutions for measuring the magnetic flux in the generator in order to plan maintenance requirements.
-
-
MAGNET-PHYSIK Dr. Steingroever GmbH
With Magnetic Physics USB Hall probes, magnetic field strength or flux density can be read directly into a computer without the need for an additional meter.
-
C 510 -
Dr. Brockhaus Messtechnik GmbH & Co. KG
The sample is exposed to a defined magnetic field within a measuring coil. A magnetic flux is created inside the material. The required current is supplied by a power amplifier.
-
Denshijiki Industry Co., Ltd.
Using the "leakage magnetic flux" phenomenon generated from the scratches, the magnetic powder (or fluorescent magnetic powder) of the ferromagnetic material scattered on the surface by magnetizing the specimen is adsorbed to the scratch. Observe this and detect scratches.
-
Hirst Magnetic Instruments Ltd
Fluxmeters for advanced measurements a Fluxmeter can be used to measure Magnetic Flux Linkage where a surface reading with a Gaussmeter is not sufficient.
-
WB10 -
R&J Measurement
The WB10 Fluxmeter is designed to measure the change of magnetic flux in measurements of magnetic properties of the magnetic materials in quasi-static and slowly floating conditions. Fluxmeter is the electronic measuring device with high sensitivity, very small drift as well as very small error of integration in a long time.