TMAG-RJJ-3.1 -
R&J Measurement
The system is a mobile version of computerized measuring system MAG-RJJ-6.0 and is designed for measure the dynamic magnetic properties of the soft magnetic materials e.g. oriented or not-oriented electrical sheet. The system provides the opportunity of a tabular and graphic presentation of the obtained data, which can be presented by means of monitor, printer or plotter. The system works under Windows 2000/XP.
-
MAG Serie -
Macintyre Electronic Design Associa
The µMAG series is the premiere, handheld instrument for the precision measurement of the vector components of weak static and low frequency magnetic fields. The superior stability, linearity and accuracy of the uMAG, compared to Hall Effect or Magnetoresistance base instruments, make it the only choice for high quality low magnetic field measurements and best choice for gerneral purpose magnetometer applications.
-
Radiant Technologies, Inc.
An exciting new area of scientific exploration examines the potential usefulness where magnetic field effects occur simultaneously with ferroelectric effects in materials and structures. Where these two properties, ferromagnetism and ferroelectricity, are coupled in the same material, the material is called a multiferroic. Radiant offers Magnetoelectric response bundle/software package to measure the magnetic coupling of multiferroic or magnetopiezoelectric devices.
-
Testboy GmbH
The magnetic field tester is suitable for rapid and precise testing of electro-magnetic switches and valves. Their tip lights up to indicate the presence of permanent, DC or AC magnetic fields. Thereby, they are so sensitive that very often it is not necessary to remove covers or cladding from machines and the function check can be carried out without any setting-up time or stopping the machine.
-
RX - 213 -
Resonance Technology
Teslameter RX-213 is a portable, hall-effect magnetic field meter, measuring simultaneously - along three mutually perpendicular axes - both the DC component and the variable component of the field (AC) with a frequency of 20 Hz - 20 kHz. The latter quantity is measured as the effective value of the magnetic field (so-called true RMS ), regardless of changes in the field as a function of time.
-
m-axis -
Matesy GmbH
m-axis is a measurement system that can be used to characterize permanent magnets in terms of their magnetic specifications (magnetic moment and magnetization angle) with high precision. In addition to the four standard measuring ranges, the modular design allows the system to be adapted to customer-specific requirements. The measurement systems can be used for 100% in-line quality control via our m-axis I/O module.
-
Hirst Magnetic Instruments Ltd
Fluxmeters for advanced measurements a Fluxmeter can be used to measure Magnetic Flux Linkage where a surface reading with a Gaussmeter is not sufficient.
-
424 -
Cooper-Atkins Corporation
Gun-Style Infrared Thermometer with Dual Laser, LED Flashlight and Hi/Lo Alarm. With HDPE carrying case and magnetic stand.
-
MFFT-1 -
Magnicon GmbH
The MFFT-1 magnetic field fluctuation thermometer is a high accuracy thermometer system for typical dilution refrigerator temperature ranges.
-
Electrical Testing Solutions
Short-Circuit Currents are currents that introduce large amounts of destructive energy in the forms of heat and magnetic force into a power system.
-
450 -
Oersted Technology
The Model 450 is a high-resolution, laboratory gaussmeter, capable of measuring magnetic fields from 0.001 Gauss to 300k Gauss (measurement range is dependent on probe used). This unit is designed for demanding applications, such as material analysis and field mapping, where low-noise, high-resolution magnetic measurements are necessary. Measurements of AC and DC magnetic fields are shown in Gauss or Tesla on the two-line vacuum fluorescent display. The Model 450 features RS232C and IEEE-488 ports, allowing the instrument to be controlled via a remote computer or automation equipment. A hall-effect gaussmeter probe is included with the Model 450, and may be selected from an extensive line of probe
-
Ferrites India
Flux meter has been the established standard for the measurement of magnetic flux density for determining total flux in a magnet or magnetic assembly. Its use was curtailed except in a few specialized areas because of many factors such as the difficulty in setting up light beam flux meter or ballistic galvanometers, limitations on the ohmic resistance of search coils, the requirement of some degree of operator skill in reading the flux meter etc. The development of the integrating type Digital Flux meter has virtually cancelled the hitherto negative aspects of fluxmeterology and has found a broad niche for many magnetic measurement applications.
-
DX-2012SA -
Dexing Magnet Tech. Co., Ltd
Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.
-
DX-102 -
Dexing Magnet Tech. Co., Ltd
DX-102 Gaussmeter is a portable gauss meter, based on the latest progress of Hall effect magnetic field measuring instrument, adopted DSP technology. Test probe adopts import GaAs linear Hall chip, the difference between any two probes is small, if damaged, it can be replaced directly. DX-102 Gaussmeter is an ideal DC magnetic field test instrument.
-
Magna-Mike 8600 -
Olympus Corp.
The Magna-Mike® 8600 is a portable thickness gage that uses a simple magnetic method to make reliable and repeatable measurements on nonferrous materials. Operation of the Magna-Mike is very simple. Measurements are made when its magnetic probe is held or scanned on one side of the test material and a small target ball (or disk or wire) is placed on the opposite side or dropped inside a container.