  • Round Wire Coil Inductors

    Pulse Electronics

    Round wire coil (RWC) inductors come in six platform sizes and enable the highest efficiency of any SMT inductor through the use of a low loss ferrite core material which minimizes AC losses and also eliminates thermal ageing.   The use of round magnetic wire instead of rectangular flat coils enables a lower cost while still maintaining a low DCR and small footprint.   The platforms have passed the AEC-Q200 stress test qualification proving the designs robustness and suitability to difficult environments but the parts are not IATF certified.  The platform range from 7.6×7.4×6.4mm to 26x26x15mm and are suitable for a wide range of applications and markets including communications, computing and industrial.

  • SIL Reed Relays

    Series 105 - Pickering Electronics

    • SoftCenter™ construction• Highest quality instrumentation grade switches• Encapsulated in a plastic package with internal mu-metal magnetic screen• Wide range of switch confi gurations -Form A, 1 Form B, 2 Form A, 1 Form C• Two pole relay requires the same board area as the single pole type• Dry and mercury wetted switches are available with the same pin configuration and footprint.• Many benefits compared to industry standard relays. Learn more here >.• Insulation resistance greater than 10E12 Ohms (1TOhms) for dry Form A devices• 5, 12 and 24 Volt coils are standard, with or without internal diode• 100% tested for dynamic contact resistance

  • Cable Identifier

    K&S Engineering and Scientific Ltd

    K&S Engineering and Scientific LTD's Cable Identifier Set offers the user a compact, portable solution for cable identification. Depending on the user preference, the Cable Function Generator and Cable Identifier Unit can be jointly housed in a rugged briefcase, or alternatively, for the user requiring a more rugged unit, can be delivered as two individual units each with their own carry-case. With the Cable Identifier Set, power optimum levels are selected by means of a rotary switch and the power levels are displayed on a meter located on the Cable Function Generator. As the Cable Identifier Unit is capable of detecting magnetic fields around mains cables it has the added advantage of the user being able to use this as a stand-alone unit to detect power cable configuration.

  • Magnetizer

    412B - Oersted Technology

    The Model 412B magnetizer provides many of the features of the Oersted Technology 300-series magnetizers in a small benchtop cabinet. This unit is designed for magnetizing parts which require lower energy levels due to their size or the magnetic material used. Like the 300-series magnetizers, the 412B is an ECS magnetizer, which allows the user to electronically vary the capacitance of the unit. The capacitor banks are internally discharged through a safety circuit in case of power failure or accidental power-down. When the 412B is connected to a properly equipped fixture, the front-panels can be inhibited through an overtemperature interlock circuit, preventing the magnetizer from being operated once the fixture begins to overheat. An external output is also provided for monitoring the magnetizing current pulse with an oscilliscope.

  • Three Loop Antenna

    VVLA-30M - Lisun Electronics Inc.

    The three loop antenna VVLA-30M  is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard , it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products.

  • Turbine Flow Meters

    AW Gear Meters

    Axial turbine flow meters are designed with wear resistant internal components to provide trouble-free operation and a long service life. Fluid entering the flow meter is first conditioned by the inlet flow straightener which reduces turbulence in the fluid. The moving fluid causes the rotor to spin at a speed that is proportional to its flow rate. As the turbine blades on the rotor pass through the magnetic field of the pickup, an electronic pulse is generated.

  • Data Retrival and Analyzer Unit

    MS 1200 - Meltronics Systemtech

    *Retrieves the Data from Magnetic / Solid State Recorders (Supports JAGUAR, AN32, IJT, ALH Platforms)*RS232/RS422/Bi-Phase/USB interface with PC AT*Presents Error Messages and Test Reports*Replay, Analysis and printout of selected parameters*Calibration facility for ADR and DAU*Portable System for Snag Analysis of Aircraft*Reports in Tabular/Graphical formats*Used to check serviceability of ADR, DAU without removing from aircraft

  • Near Field Probes 30 MHz up to 6 GHz

    XF1 set - Langer EMV-Technik GmbH

    The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.

  • Level Test (& Calibration) Rig

    LTR600 Series - Smartech Inc.

    Level Test & Calibration Rig – a boon to Petrochemical Refineries & other process Industries – relies on state of the art simple design for Primary & Interface liquid level testing & calibration of various types / models of Level Measurement (& control) devices including Float / Displacer / Radar / Capacitance / Ultrasonic / Magnetic – for both In-built & External Chamber types. Available Ranges / Span are 1000mm / 1500mm & 2000mm (1 / 1.5 & 2 Meters).

  • C Series Frequency Input Module

    NI

    The C Series Frequency Input Module is designed to acquire isolated frequency inputs from magnetic pickup sensors, variable reluctance sensors, Hall effect sensors, and other transducers with a frequency output. Additionally, the C Series Frequency Input Module provides isolation, configurable thresholds, selectable filtering, and embedded counter measurement logic. These measurements can be synchronized with other frequency, analog, digital, and counter measurements in a single acquisition.

  • Absolute Optical Inclinometer

    A2T - U. S. Digital

    The A2T is a single axis, digital gravity angle sensor. The A2T serves as a full 360 range absolute tilt sensing programmable level with either digital or analog output. Internally, a rotary bar coded disk is mounted to a weighted gravity driven wheel. A micro-controller strobes an LED to transfer the bar code image onto an optical linear array, then decodes the position every 2 mSec. Magnetic damping provides fast response and settling time while virtually eliminating overshoot and oscillations. An internal EEPROM stores field programmable parameters such as resolution, zero position, direction swap, and mode. This second generation design virtually eliminates the primary accuracy limitation of first generation inclinometers, which is sitation (hysteresis).

  • Cable Identification & Phasing

    VCi-3™ - ndb Technologies Inc.

    The VCi-3™ system is designed for cable and phase identification, mainly for instal­lation or maintenance purposes on three-phase electrical networks during power shutdowns.The transmitter module injects a low current on the cable conductors by direct con­tact or magnetic clamps methods. A voice message is recorded by the user and will be transmitted along with digital signals. Groundings stay connected at both ends of the three-phase circuit during the test. The detector module is used at the other end of the cable system.

  • Relays, Switches, Sensors

    CR MAGNETICS, INC.

    CR Magnetics Sensing Relays and Switches provide a simple method of monitoring electrical properties and alerting a system to a fault or event condition. These products are available with a wide variety of configurations, including time delays, various output styles and logic. From simple proving switches, to fully featured high performance ground fault sensing. Our relays and switches will provide the designer with the tools needed to implement many different control and event sensing schemes.

  • EMI Test System

    EMI-9KA - Lisun Electronics Inc.

    EMI-9KA is an automatic EMI receiver. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KA is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KA fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.

  • Materials Measurement Suite

    N1500A - Keysight Technologies

    With Keysight N1500A materials measurement software suite, you can determine the intrinsic electromagnetic properties of many dielectric and magnetic materials. The complete system is based on a versatile Keysight network analyzer which measures the material’s response to RF or microwave energy. The N1500A software controls the network analyzer and calculates results. Depending on the Keysight network analyzer and sample holder or fixture used, frequencies can extend from a few hundred MHz into the low THz.