Pickering Interfaces Ltd.
These 8x9 RF Switch Cards are suitable for switching frequencies up to 500MHz. Available in either 50 or 75 versions with SMB coaxial connectors. These switch cards are intended for the easy construction of high-performance bidirectional matrix switching systems. Automatic isolation switches are located on all coaxial connections, these disconnect the matrix from the external test fixture. This maximizes isolation and RF performance.
-
Pickering Interfaces Ltd.
Pickering's 6U high-density matrices are suitable for switching frequencies to beyond 250MHz. The 45- 720A module is available in 50 and 75 Ohm versions with a choice of coaxial connectors. It is intended for the easy construction of high-performance bidirectional matrix switching systems. Automatic Isolation Switches are located on all coaxial connectors, these disconnect the matrix from the external test fixture - this maximizes isolation and RF performance.
-
Hinds Instruments, Inc.
The 2-MGEM Optical Anisotropy Factor Measurement System is a normal-incidence polarization reflection microscope designed to measure the sample Mueller matrix and is a 2008 R&D 100 Award Winner. This system is designed specifically to evaluate the Optical Anisotropy Factor (OPTAF) of cross sections of TRISO nuclear fuel pyrocarbon layers. Other possible material characterizations include measuring Mueller matrix elements of other crystals, carbon compounds, and thin film coatings (e.g. surfacedeposition films) at normal incidence. The 2-MGEM can also measure retardation (d), circular diattenuation (CD) and the polarization factor (ß). These parameters are not measurable using older techniques, since those techniques do not incorporate a compensating optical element.
-
NEX DE -
Applied Rigaku Technologies, Inc
As a premium high-performance benchtop EDXRF elemental analyzer, the NEX DE delivers wide elemental coverage with an easy-to-learn Windows®-based QuantEZ software. Non-destructively analyze sodium (Na) through uranium (U) in almost any matrix, from solids and alloys to powders, liquids, and slurries.
-
ZenQ
With the widespread proliferation of mobile devices and platforms, mobile application testing matrix has become more complex than ever. Moreover, the rapid evolution of different platforms, OS versions, form factors, screen sizes, OS’s, mobile networks, and carriers add to the complexity of mobile app testing.
-
DRK8663 -
Shandong Drick Instruments Co., Ltd.
Optical measurements using automatic balance principle, the measurement results are automatically displayed by the dot matrix LCD. It retains WZZ-1, WZZ-2B reliable, high sensitivity, no human error, the advantages of easy reading, but also added a specific rotation, concentration and Brix measurement mode, greatly facilitate the users.
-
Micromatter
These multi-element standards consist of multi-layer thin film coatings, one on top of the other, upto a maximum of 6 elemental coatings. It is generally recommended to have coating thicknesses < 20 µg/cm2, so as to cause negligible notable matrix effects, in particular absorption of X-rays emitted in lower deposits by those covering them.
-
AFS-12WB -
Matrix Test Equipment Incorporated
Models AFS-12WB contain banks of Matrix Model FLT-1 filters. Each filter may be individually selected. The Model AFS-12WB retains the manual operation in addition to remote control through the GPIB IEEE-488 interface. Optional internal Post Amplifier PA-20-20 with a gain of 0, 17 and 32dB @ +5dBm max..
-
AN-6150 -
Ametek Power Instruments
The Model AN-6150 is a compact, cellular display unit which allows a wide variety of customer configurations. Any combination of four standard window sizes can be accommodated in each cell. These cells can be configured in any matrix up to 6 high and 6 wide. The single module is designed to DIN 2.84" x 5.67" standard.
-
DTS-C -
Matrix Test Equipment Incorporated
The Model DTS Distortion Test Sets combine Matrix products with those of other manufacturers. When properly equipped, a Model DTS can measure virtually any parameter important to the CATV industry. Controlled completely through the (GPIB) IEEE-488 bus interface, a Model DTS allows rapid, repetitive, and objective readings in a production-type environment.
-
Euresys Inc.
Automatic detection of the code in the imageDecodes ECC200, ECC000, ECC050, ECC080, ECC100 and ECC140 codesComputes quality indicators as per ANSI/AIM, ISO/IEC 15415, ISO/IEC TR 29158 and SEMI T10-0701 standardsVery fast operationImpressive robustness to noise, blur and distortionSupport of GS1 Data Matrix codesEfficient reading of codes in grid layoutMultiple codes reading
-
Pickering Interfaces Ltd.
Pickering low-thermal EMF LXI matrices offer excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in automatic test equipment, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC microvolt measurements.
-
U1816C -
Keysight Technologies
The Keysight U1816C is a switch matrix that consists of two single-pole-six-throw (SP6T) switches. It allows switching of multiple signal paths without physically changing the connections. This allows multiple tests to be performed with the same setup, eliminating the need for frequent connects and disconnects. An entire testing process can be automated, increasing the throughput in high-volume production environments.
-
U1816A -
Keysight Technologies
The Keysight U1816A is a switch matrix that consists of two single-pole-six-throw (SP6T) switches. It allows switching of multiple signal paths without physically changing the connections. This allows multiple tests to be performed with the same setup, eliminating the need for frequent connects and disconnects. An entire testing process can be automated, increasing the throughput in high-volume production environments.
-
U3020AS26 -
Keysight Technologies
The Keysight U3020AS26 is a switch matrix that consists of two single-pole-six-throw (SP6T) switches. It allows switching of multiple signal paths without physically changing the connections. This allows multiple tests to be performed with the same setup, eliminating the need for frequent connects and disconnects. An entire testing process can be automated, increasing the throughput in high-volume production environments.