40-517-002 -
Pickering Interfaces Ltd.
The 40-515/516/517 2 Amp, 2-Pole Matrix Modules form part of the System 40 PXI ProgrammableSwitching system. Each module consists of a matrix of 64 2-pole electro-mechanicalrelays under the control of a PXI/PCI interface.These modules are designed for switching medium voltage/power signals in test applicationswhere reed relays do not have sufficient rating. They are also suitable for telecomsapplications where send and return signals need to be switched simultaneously.
-
40-516-002 -
Pickering Interfaces Ltd.
The 40-515/516/517 2 Amp, 2-Pole Matrix Modules form part of the System 40 PXI ProgrammableSwitching system. Each module consists of a matrix of 64 2-pole electro-mechanicalrelays under the control of a PXI/PCI interface.These modules are designed for switching medium voltage/power signals in test applicationswhere reed relays do not have sufficient rating. They are also suitable for telecomsapplications where send and return signals need to be switched simultaneously.
-
40-527A-001 -
Pickering Interfaces Ltd.
The 40-527A, is a PXI single-pole 64x2 matrix and is part of a range of matrices supporting 128 crosspoints. All models use gold-plated contact electromechanical relays.
-
40-727-001 -
Pickering Interfaces Ltd.
RF Matrix Modules suitable for switching frequencies to 300MHz (50Ω version). The modules are available in either 50Ω or 75Ω versions with a choice of coaxial connectors.
-
40-583-001 -
Pickering Interfaces Ltd.
The 40-583 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 64x4 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 160 pin DIN 41612 connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.
-
40-582-001 -
Pickering Interfaces Ltd.
The 40-582 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 16x16 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 78 pin D-Type connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.
-
40-580-001 -
Pickering Interfaces Ltd.
The 40-580 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 32x8 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 160 pin DIN 41612 connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.
-
778572-31 -
NI
512-Crosspoint, 1-Wire PXI Matrix Switch Module—The PXI‑2531 is a high-density PXI matrix switch module built to serve high‑channel‑count automated test systems. Featuring compact reed relays with switching speeds up to 2,000 cycles/s, the PXI‑2531 is designed for low‐current, high‐speed switching. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
778572-33 -
NI
256-Crosspoint, 1-Wire PXI Matrix Switch Module—The PXI‑2533 is a high-density 4x64 PXI matrix switch module built to serve high‑channel‑count automated test systems. Featuring solid-state relays (SSRs), the PXI‑2533 offers unlimited mechanical lifetime and the ability to route 55 W simultaneously on all channels. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
778572-34 -
NI
256-Crosspoint, 1-Wire PXI Matrix Switch Module—The PXI‑2534 is a high-density 8x32 PXI matrix switch module built to serve high‑channel‑count automated test systems. Featuring solid-state relays (SSRs), the PXI‑2534 offers unlimited mechanical lifetime and the ability to route 55 W simultaneously on all channels. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
778739-01 -
NI
The PXI‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXI‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
40-521-021 -
Pickering Interfaces Ltd.
An ultra high density matrix module is configured as a 24x8, this range is availablein a choice of reed relay formats: 1-pole (shown here), 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability RutheniumElectro-Plated Reed Relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance.
-
40-521-022 -
Pickering Interfaces Ltd.
Typical applications for this high density matrix include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability rutheniumelectro-plated reed relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, 7 PXI modules will form a 168x8 Matrix, a total of 1344 crosspoints in a 7-slot PXI Chassis. All 40-521 series modules are fitted with reed relays (ruthenium sputtered type), these offer very long life with good low level switching performance and excellent contact resistance stability.Spare Reed Relays are built onto the circuit board to facilitate easy maintenance with minimum downtime.
-
40-532-022 -
Pickering Interfaces Ltd.
This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.
-
40-531-022 -
Pickering Interfaces Ltd.
Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.