Showing results: 406 - 420 of 1987 items found.
-
40-524-021 -
Pickering Interfaces Ltd.
Medium density PXI dual 46x4, 1-pole matrix - it is also available inreed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
40-585-001 -
Pickering Interfaces Ltd.
Our model 40-585, along with the following models40-584, 40-586A, 40-587Aare high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. The PXI matrix modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type or 160 pin DIN 41612 connector that is fully supported by the wide range of our cable and connector accessories.
-
50-513A-021 -
Pickering Interfaces Ltd.
The 50-510A series of matrix cards feature a wide range of switching configurations (22x4, dual 20x4, 22x8 and 44x4). Larger matrices may be constructed by daisy chaining the common signals from multiple cards. Expansion cables are available for the 50-512 and 50-513: The 50-512 can be expanded to 44x8 or the 50-513 can be expanded to 88x4 using two cards linked by the ribbon cable assembly 50-976-020-0.1M. Also the 50-512 can be expanded to 22x16 or the 50-513 can be expanded to 44x8 using two cards linked by the ribbon cable assembly 50-976-050-0.1M.
-
50-513A-022 -
Pickering Interfaces Ltd.
The 50-510A series of matrix cards feature a wide range of switching configurations (22x4, dual 20x4, 22x8 and 44x4). Larger matrices may be constructed by daisy chaining the common signals from multiple cards. Expansion cables are available for the 50-512 and 50-513: The 50-512 can be expanded to 44x8 or the 50-513 can be expanded to 88x4 using two cards linked by the ribbon cable assembly 50-976-020-0.1M. Also the 50-512 can be expanded to 22x16 or the 50-513 can be expanded to 44x8 using two cards linked by the ribbon cable assembly 50-976-050-0.1M.
-
50-510A-021 -
Pickering Interfaces Ltd.
The 50-510A series of matrix cards feature a wide range of switching configurations (22x4, dual 20x4, 22x8 and 44x4). Larger matrices may be constructed by daisy chaining the common signals from multiple cards. Expansion cables are available for the 50-512 and 50-513: The 50-512 can be expanded to 44x8 or the 50-513 can be expanded to 88x4 using two cards linked by the ribbon cable assembly 50-976-020-0.1M. Also the 50-512 can be expanded to 22x16 or the 50-513 can be expanded to 44x8 using two cards linked by the ribbon cable assembly 50-976-050-0.1M.
-
50-512A-022 -
Pickering Interfaces Ltd.
The 50-510A series of matrix cards feature a wide range of switching configurations (22x4, dual 20x4, 22x8 and 44x4). Larger matrices may be constructed by daisy chaining the common signals from multiple cards. Expansion cables are available for the 50-512 and 50-513: The 50-512 can be expanded to 44x8 or the 50-513 can be expanded to 88x4 using two cards linked by the ribbon cable assembly 50-976-020-0.1M. Also the 50-512 can be expanded to 22x16 or the 50-513 can be expanded to 44x8 using two cards linked by the ribbon cable assembly 50-976-050-0.1M.
-
50-510A-022 -
Pickering Interfaces Ltd.
The 50-510A series of matrix cards feature a wide range of switching configurations (22x4, dual 20x4, 22x8 and 44x4). Larger matrices may be constructed by daisy chaining the common signals from multiple cards. Expansion cables are available for the 50-512 and 50-513: The 50-512 can be expanded to 44x8 or the 50-513 can be expanded to 88x4 using two cards linked by the ribbon cable assembly 50-976-020-0.1M. Also the 50-512 can be expanded to 22x16 or the 50-513 can be expanded to 44x8 using two cards linked by the ribbon cable assembly 50-976-050-0.1M.
-
50-511A-022 -
Pickering Interfaces Ltd.
The 50-510A series of matrix cards feature a wide range of switching configurations (22x4, dual 20x4, 22x8 and 44x4). Larger matrices may be constructed by daisy chaining the common signals from multiple cards. Expansion cables are available for the 50-512 and 50-513: The 50-512 can be expanded to 44x8 or the 50-513 can be expanded to 88x4 using two cards linked by the ribbon cable assembly 50-976-020-0.1M. Also the 50-512 can be expanded to 22x16 or the 50-513 can be expanded to 44x8 using two cards linked by the ribbon cable assembly 50-976-050-0.1M.
-
Pickering Interfaces Ltd.
The 50-510A series of matrix cards feature a wide range of switching configurations (22x4, dual 20x4, 22x8 and 44x4). Larger matrices may be constructed by daisy chaining the common signals from multiple cards. Expansion cables are available for the 50-512 and 50-513: The 50-512 can be expanded to 44x8 or the 50-513 can be expanded to 88x4 using two cards linked by the ribbon cable assembly 50-976-020-0.1M. Also the 50-512 can be expanded to 22x16 or the 50-513 can be expanded to 44x8 using two cards linked by the ribbon cable assembly 50-976-050-0.1M.
-
781421-17 -
NI
16x22, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2817 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
781420-17 -
NI
16x22, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2817 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
40-529A-001 -
Pickering Interfaces Ltd.
PXI single pole matrices each supporting 128 cross points. All models use electromechanical relays. The modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type connector.
-
40-528A-001 -
Pickering Interfaces Ltd.
PXI single pole matrices each supporting 128 cross points. All models use electromechanical relays. The modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type connector.
-
40-520-205 -
Pickering Interfaces Ltd.
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
40-520-401 -
Pickering Interfaces Ltd.
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.