Showing results: 916 - 930 of 1987 items found.
-
782835-38 -
NI
256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module—The PXIe‑2738 is a high‐density 8x32 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
782835-39 -
NI
256-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2739 is a high‐density 16x16 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
60-750-133-C -
Pickering Interfaces Ltd.
The 60-750-133-C is a single 3x3 10GHz microwave matrix with internal termination and loop-thru. It is part of the 60-750/751 range of LXI Microwave Switches controlled through an LXI compliant Ethernet connection.
-
60-750-144-C -
Pickering Interfaces Ltd.
The 60-750-144-C is a single 4x4 10GHz microwave matrix with internal termination and loop-thru. It is part of the 60-750/751 range of LXI Microwave Switches controlled through an LXI compliant Ethernet connection.
-
M9120A -
Keysight Technologies
The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
40-505A-001 -
Pickering Interfaces Ltd.
The 40-505A-001 is a medium density matrix module able to switch up to 2 A or 300 VDC/250 VAC. It is in 42x4 1-pole configuration and constructed using high quality electro-mechanical relays for high switching confidence.
-
40-592A-118 -
Pickering Interfaces Ltd.
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines. Typical applications are in automotive and aerospace industries which involve safety or mission critical systems that have to behave predictably when cabling or sensor faults occur.
-
40-592A-014 -
Pickering Interfaces Ltd.
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines. Typical applications are in automotive and aerospace industries which involve safety or mission critical systems that have to behave predictably when cabling or sensor faults occur.
-
40-566A-003 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. They are available in 4 or 8-slot PXI sizes and are constructed using quality electro-mechanical relays for high switching confidence.
-
40-566A-107 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. They are available in 4 or 8-slot PXI sizes and are constructed using quality electro-mechanical relays for high switching confidence.
-
40-566A-106 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. They are available in 4 or 8-slot PXI sizes and are constructed using quality electro-mechanical relays for high switching confidence.
-
40-566A-104 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. They are available in 4 or 8-slot PXI sizes and are constructed using quality electro-mechanical relays for high switching confidence.
-
40-566A-101 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. They are available in 4 or 8-slot PXI sizes and are constructed using quality electro-mechanical relays for high switching confidence.
-
40-566A-105 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. They are available in 4 or 8-slot PXI sizes and are constructed using quality electro-mechanical relays for high switching confidence.
-
40-566A-001 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. They are available in 4 or 8-slot PXI sizes and are constructed using quality electro-mechanical relays for high switching confidence.