Showing results: 976 - 990 of 1987 items found.
-
40-588-212 -
Pickering Interfaces Ltd.
The 40/42-588-212 is a high density 16x8 2-pole PXI matrix module capable of switching up to 2 A at 220 VDC/250 VAC. The module is in 2-slot format and is constructed using quality electromechanical relays for high switching confidence. A larger 32x8 2-pole version is also available.
-
42-588-212 -
Pickering Interfaces Ltd.
The 40/42-588-212 is a high density 16x8 2-pole PXI matrix module capable of switching up to 2 A at 220 VDC/250 VAC. The module is in 2-slot format and is constructed using quality electromechanical relays for high switching confidence. A larger 32x8 2-pole version is also available.
-
42-588-222 -
Pickering Interfaces Ltd.
The 40-588-222 is a high density 32x8 2-pole PXI matrix module capable of switching up to 2 A at 220 VDC/250 VAC. The module is in 2-slot format and is constructed using quality electromechanical relays for high switching confidence. A smaller 16x8 2-pole version is also available.
-
40-559-201-256x4 -
Pickering Interfaces Ltd.
This range of BRIC ultra-high-density large PXI matrices are available in 2, 4 or 8-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays. With their high level of switching density, these PXI matrices allow a complete Functional ATE system to be housed in a single 3U PXI chassis and allow the use of much lower cost 8 or 14-slot chassis. The 40-559 matrices can be used in many industries; typical applications include automotive ECU and semiconductor package testing. Dual analog busing for the narrower matrix options, enable completely separate matrices within a single module for parallel testing.
-
40-837-001 -
Pickering Interfaces Ltd.
The 40-837-001 is a 75Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-101 -
Pickering Interfaces Ltd.
The 40-837-101 is a 75Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-002 -
Pickering Interfaces Ltd.
The 40-837-002 is a 75Ω 2x2 RF matrix with 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-102 -
Pickering Interfaces Ltd.
The 40-837 is a 75 2x2 RF matrix available with 1 or 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-877-001 -
Pickering Interfaces Ltd.
The 40-877-001 is a 50Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-877 modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-877-101 -
Pickering Interfaces Ltd.
The 40-877-101 is a 50Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-877 modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-877-002 -
Pickering Interfaces Ltd.
The 40-877-002 is a 50Ω 2x2 RF matrix with 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-877 modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-877-102 -
Pickering Interfaces Ltd.
The 40-877-102 is a 50Ω 2x2 RF matrix with 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-877 modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-587A-001 -
Pickering Interfaces Ltd.
Our model 40-587A, along with the following models40-584, 40-585, 40-586Aare high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. The PXI matrix modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type or 160 pin DIN 41612 connector that is fully supported by the wide range of our cable and connector accessories.
-
M9122A -
Keysight Technologies
The M9122A is an 8x32 full crosspoint switch matrix offering high-voltage switching in a high-density PXI module. This module allows for higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This module is configured with a common ground. The durable armature switches are capable of switching up to 100Vrms, with up to 60W of power. The 8-wide bus can be used to route signals between your instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
YAV90097 -
6TL Engineering