Showing results: 2716 - 2730 of 10608 items found.
-
D4141 -
COMET SYSTEM, s.r.o.
Thermometer, hygrometer, barometer is designed for measurement and datalogging of temperature, relative humidity and atmospheric pressure into the internal non-volatile memory.
-
Process Sensing Technologies
The LD series analyzers offer direct and continuous measurements of impurities in a gas. They are compact and rack-mountable for industrial & laboratory use.
-
S96460B -
Keysight Technologies
S96460B provides mismatch-corrected true-mode stimulus and enables accurate balanced measurements on 4-port E5080B vector network analyzers.
-
S95460B -
Keysight Technologies
S95460B provides mismatch-corrected true-mode stimulus and enables accurate balanced measurements on M980xA PXI vector network analyzers.
-
S93460B -
Keysight Technologies
The S93460B provides mismatch-corrected true-mode stimulus and enables accurate balanced measurements on 4-port PNA or PNA-X network analyzers.
-
787230-0R2 -
NI
The HDBNCM-BNCF connects measurement and signal devices. You can also use this cable to connect to other male BNC cables.
-
Advantech Co. Ltd.
Multifunction cards provides analog input, analog output, digital input, digital output, and counter/timer for voltage measurements.
-
Sensors, Inc.
Accurate measurement of gases and their concentrations is critical in many applications, and often poses a major challenge. Sensors' experience with different measurement principles, including NDIR, NDUV, and thermal conductivity, along with the ability to provide special combinations of these techniques within our products, enables us to tackle these challenges. In addition, our experience goes into every detail of our gas analyzers, ensuring reliable results, even under harsh conditions. Our skilled team of experts is happy to assist you in finding the optimized solution for your measurement requirements, with either off-the-shelf components or a customized solution.
-
44500 -
M. C. Miller Company
Rugged, lightweight case - safe to use on wet ground• Weatherproof, even with lid removed - IP67 rating for dust and water intrusion• Convenient case lid removal for ease of movement, with test leads attached, to new measurement locations• Resistance measurement range from 0.01Ω to 1.1MΩ • Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 97Hz (the unit’s operating frequency)• Runs on a set of C-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source
-
Shenzhen Graigar Technology Co.,Ltd.
Measurement of the speed of a rotating shaft is a common requirement in many industrial and laboratory applications. Such measurements have usually been carried out in the past with the help of contact type tachometers with friction drive. More recently digital optical non-contact tachometers have been designed which count the reflected pulses from a white patch on the shaft and then display the speed in rpm. The light source is usually a filament lamp operating with dry cells leading to limited life and illumination. A similar ideawith magnetic pick-up from a particular area of the shaft has also been used for speed measurement.
-
National Technical Systems
To determine the failure point or break strength, you will need to define what a break is (break detector). Generally, there are two common types of breaks: the sharp break is referred to the measurement when load or force drops by 5% from its peak load measurement. A percentage break is another form of break and is generally determined by the sample material and its relationship to load degradation from a peak load measurement. A plastic material will likely have a load drop of 5%, but not represent a break. In this case, a percentage break would need to be applied. In a tensile test, the breaking load is the break strength.
-
450 -
Oersted Technology
The Model 450 is a high-resolution, laboratory gaussmeter, capable of measuring magnetic fields from 0.001 Gauss to 300k Gauss (measurement range is dependent on probe used). This unit is designed for demanding applications, such as material analysis and field mapping, where low-noise, high-resolution magnetic measurements are necessary. Measurements of AC and DC magnetic fields are shown in Gauss or Tesla on the two-line vacuum fluorescent display. The Model 450 features RS232C and IEEE-488 ports, allowing the instrument to be controlled via a remote computer or automation equipment. A hall-effect gaussmeter probe is included with the Model 450, and may be selected from an extensive line of probe
-
CX-118A -
Shenzhen Chuangxin Instruments Co., Ltd.
1 It's using reciprocal counting technique, high accuracy, wide measuring range, truly equal precision measurement, fast speed measurement, high sensitivity.2 single-chip microprocessor technology cycle frequency measurement and intelligent management, making the instrument has high reliability and excellent performance / price ratio.3 It's using LSI design, the use of CPLD devices, instrument components greatly reduced, reliability has been greatly improved, the average time between failures ≥10000h.The machine looks nice, small size, light weight, easy to use.
-
Shenzhen Chuangxin Instruments Co., Ltd.
1 It's using reciprocal counting technique, high accuracy, wide measuring range, truly equal precision measurement, fast speed measurement, high sensitivity.2 single-chip microprocessor technology cycle frequency measurement and intelligent management, making the instrument has high reliability and excellent performance / price ratio.3 It's using LSI design, the use of CPLD devices, instrument components greatly reduced, reliability has been greatly improved, the average time between failures ≥10000h. The machine looks nice, small size, light weight, easy to use.
-
TS-8700 -
Ono Sokki
TS-8700 Torque Station Pro is torque measurement system for motor basic property with high precision and high response.In combination with the motor torque detector MT series with the TH series torque detector, it is possible to perform high-precision, high-response motor torque measurement with up to 5.12 kHz sampling and ± 0.1 % of accuracy.In addition, the high rigidity compact torque detector RH series (10 N・m/ 20 N・m) can be mounted on the MT series. It has achieved more highly accurate measurement with ±0.05 %/F.S.This system is ideal for measuring torque fluctuations of motors on-board such as EPS motors.