Showing results: 4906 - 4920 of 10458 items found.
-
Li-Cor Environmental, Inc.
A long-term system from LI-COR lets you accomplish more with your multiplexed soil gas flux measurements. Connect up to 36 chambers to evaluate both spatial and temporal flux variation across a footprint of up to 2800 square meters.
-
7505-K007 -
Chroma ATE Inc.
The Chroma 7505-K007 Thin Film Thickness Automated Optical Metrology System equipped with 3D sensor is suitable for Roll to Roll processing and thin film thickness measurement. The stage embedded with vacuum adsorption function, making soft UUT a flat surface.
-
CB52 -
CAMI Research Inc. (CableEye®)
The CB52 is intended for periodic calibration verification of the Kelvin 4-wire resistance measurement module – an optional, add-on module that may be purchased with any new hipot system, or added to an existing high voltage tester as an upgrade. To ensure that 4-wire resistance measurements remain accurate, CAMI recommends running the verification check every quarter. A 4-wire measurement module that is out of calibration will give inaccurate results. Some (maybe all) resistance measurements will be incorrect. Consequently, it may Pass what should Fail and, conversely, Fail what should Pass. In other words product yield will be contaminated due to unreliable measurements.
-
Saluki Technology Inc.
S87234D/E/F/L USB peak and average power sensor is a diode-detection broadband power measurement instrument based on the USB 2.0 interface, which can realize accurate average power measurement, pulse power measurement with large dynamic range and CCDF statistical measurement analysis. The frequency range covers 50MHz to 67GHz, the highest power accuracy can reach 0.2dB, the video bandwidth is ≥30MHz, and the rise/fall time is ≤13ns.S87234 series can flexibly expand the power measurement function of electronic measuring instruments and test systems, and is mainly used for field testing, production line testing and system integration.
-
BAUR TDR 510 -
BAUR Prüf- und Messtechnik GmbH
Handheld Time Domain Reflectometer TDR 510. The BAUR handheld time domain reflectometer TDR 510 is used for fault location in all metal cables such as power cables, coaxial cables, data cables and communication cables. The BAUR TDR 510 comes with a device storage for 50 measurements and the option to compare the trace of an active TDR measurement with a stored trace.* Configurable for various measurement ranges and cable types* Standard-compliant, safe measurements on live cables through the measurement category CAT IV / 600 V* Ideal for fault location in the area of telecommunication, video technology, data and security technology
-
Barben Analytical
Conductivity sensors measure the specific conductance of liquid processes. The specific conductance is directly related to the presence of ionic species and their concentration. Barben Analytical offers a full range of two electrode and four electrode contacting conductivity sensors for a variety of industrial measurement applications.
-
AMETEK Drexelbrook
This reliable level transmitter is specially designed to maximize the throughput of oil/water separators and accurately measures the electrical interface in the emulsion even in upset conditions. This measurement is critical because the separation vessel operates at maximum efficiency when the electrostatic grid is close as possible to the interface.
-
Euresys Inc.
Detection of 3D objects in point clouds or ZMapsMetric detection criteriaCompatible with arbitrary regionsComputation of precise 3D measurements, like size, orientation, area, volume…Automatic extraction of object local support plane2D and 3D graphical display of the resultsFull-featured interactive demo application
-
ECAT STGMM 6 -
CSM Products, Inc.
Precise and synchronous acquisition of mechanical strain directly at the strain gauge points of application: This is what the EtherCAT®-based measurement module ECAT STGMM 6 with six time-synchronous strain gauge inputs for quarter-, half- and full bridges has been designed for
-
alpha-SE® -
J.A. Woollam Co., Inc.
For routine measurements of thin film thickness and refractive index, this ellipsometer allows you to mount a sample, choose the model that matches your film, and press "measure". You have results within seconds. Works with your materials - dielectrics, semiconductors, organics, and more.
-
CT8022 -
General Technologies Corp.
State of the Art ergonomic design and styling for easier handling and use when compared to conventional multimeters. Fully automatic range selection. Large 3 digit LCD display with scale indicators. AC/DC Voltage measurement from 1 mV to 600 Volt
-
MP1200 -
Tinius Olsen
The MP1200 melt flow tester/extrusion plastometer features the latest in melt flow measurement technology and allows operators to quickly and easily set up and perform melt flow tests according to ASTM D1238, ISO 1133-1 & 2 and other international and industrial specifications.
-
FOG100 -
CDP Systems Corp.
Femtosecond optical gating (FOG) methods give best temporal resolution in light induced fluorescence lifetime measurements. Since 1997 we manufacture model FOG100-DX for operation with femtosecond oscillators and we offer now FOG100-DA for operation with femtosecond amplified pulses.
-
K6 -
KRÜSS GmbH
Our Force Tensiometer – K6 is a robust and reliable manual instrument for measuring surface tension and interfacial tension using the ring method. As a quality product from our precision mechanical workshop, it produces fast, easy and accurate measurements for surfactant solutions and solvents.
-
PF-300 -
Seward Medical
The PF-300 gas flow analyser is a compact and accurate flow analyser compatible with 13 gas standards and 7 gas types. The unique and compact design offers accurate measurement of flow, volume, oxygen, temperature, humidity, dew point, high and low p