Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 7036 - 7050 of 10458 items found.

  • PXI Vector Component Analyzer, 100 kHz to 53 GHz

    M9818AS - Keysight Technologies

    The PXI vector component analyzer enables complex multiport device characterization with continuous wave and modulated signal measurements.

  • Multifunction ISA DAQ Cards

    Advantech Co. Ltd.

    Multifunction cards provides analog input, analog output, digital input, digital output, and counter/timers for signal measurement.

  • Carbon and Sulfur in Inorganic Materials by the Combustion Infrared Detection Technique

    844 Series - Leco Corp.

    LECO combined our customers' feedback with innovative engineering to develop the CS844, an elemental analyzer designed for wide-range measurement of carbon and sulfur content of primary steels, ores, finished metals, ceramics, and other inorganic materials using the combustion technique. Our exclusive MS Windows®-based software, coupled with a boom-mounted touch interface, gives you complete access to instrument control, analysis settings, diagnostics, reporting, and more—without sacrificing valuable bench space.

  • CellTest Multichannel Potentiostat

    Ametek Scientific Instruments

    Simultaneous Electrochemical Impedance Spectroscopy (EIS) tests can be run on multiple cells by connecting Solartron 1455A/1451A series frequency response analyzer (FRA) modules to the 1470E. These FRAs can operate in single sine correlation or multi-sine / Fast Fourier Transform (FFT) analysis mode, providing the ultimate in speed, precision and accuracy. The 1455A FRA provides high performance impedance measurements over the frequency range 10 μHz to 1 MHz, while the 1451A FRA operates from 10 μHz to 100 kHz.

  • Chlorophyll Concentration

    Apogee Instruments, Inc.

    Linear OutputThe Apogee chlorophyll concentration meter is calibrated to measure chlorophyll concentration in leaves with units of mol of chlorophyll per m2. This eliminates the problems with relative indexes of chlorophyll concentration.For reference and comparison purposes, the Apogee meter also outputs relative units [CCI or SPAD] if desired.For details see: Parry, C., Blonquist Jr., J.M., & Bugbee, B. 2014. In situ measurement of leaf chlorophyll concentration: analysis of the optical/absolute relationship. Plant, Cell and Environment 37:2508-2502.

  • Color Screen Sound Level Meter

    AWA6228+ - Hangzhou Aihua Instruments Co., Ltd.

    * A handhold noise measuring instrument* Multifunction and user- friendly sound level meter(sound level meter, integrating SLM, 1/1 OCT,   1/3 OCT analyzer, FFT analyzer, Noise dosimeter)* 240×320 color screen* Measurement range up to 142dB* Synchronously do integrating measure, statistical, real-time 1/1 OCT, 1/3 OCT, FFT analysis and noise dosimeter measure* Comply with IEC 61672 Class 1 and IEC61260 Class 1 and IEC 61252

  • Cross Domain Development Kit

    XDK - Robert Bosch GmbH

    Enjoy an all-in-one prototyping platform for sensor based IoT projects. It’s packed with state of the art sensor technology and ready-to-use software packages, capable of fulfilling all your IoT application needs. Start building your project right away to test your idea and validate your concept. Built-in sensors: Accelerometer, Gyroscope, Magnetometer, Inertial measurement unit, Humidity/ Pressure/ Temperature/ sensor, Acoustic noise sensor, Digital light sensor.

  • Data Logger Software Module

    Metra Mess- und Frequenztechnik in Radebeul e.K.

    *Data logger and monitor*Records binary or text files which can be processed by other software*Bar graph and numeric display*Level recording if signal exceeds threshold*Adjustable trip delay*Pre- and post-triggering*Recording of vibration acceleration*VM-REC+ also for velocity and displacement*RMS, positive, negative and unsigned peak values, instantaneous value*Up to four signals per window*One VM-REC license can be operated simultaneously up to four times with different settings *External Messengers*Offline measurement

  • DC Current Bias Supply

    DC1000A - Voltech

    To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.

  • DC-Resistance Meter

    HopeTech

    High-stability internal resistance of the battery Meter.The main battery internal resistance and battery voltage. This product can simultaneously measure the resistance and voltage and to compare battery internal resistance and open-circuit voltage.The CHT3560 standard RS232C and HANDLER interface automated measurement fast and accurate judgment the battery deterioration of the situation, sorting products suitable for battery assembly line and factory inspection. Low resistance characteristics can be used to characterize the mechanical and electrical components down low current test conditions.

  • Dynamic Mechanical Analyzer

    DMA/SDTA 1 + - Mettler-Toledo, LLC

    The METTLER TOLEDO DMA/SDTA1+ sets new standards in the market. In comparison with conventional DMA instruments it offers new and unique performance benefits: A frequency range up to 1000 Hz for material behavior simulation and accurate determination of moduli through the presence of a dedicated force sensor. Unique measurement of both displacement and force results in a very accurate determination of moduli. Wide force range from 1 mN to 40 N allows you to measure very soft and very stiff samples

  • Eight-channel USB Voltage and Thermocouple DAQ

    Model DI-2008 - DATAQ Instruments, Inc.

    Includes DI-2008 instrument, WinDaq software, calibration certificate, terminal screwdriver, and USB cable (6-feet). Eight differential and isolated analog input channels. Seven bi-directional digital input ports, including: Counter input for totalizing applications, Rate input for frequency/flow/rpm applications. ChannelStretch™ channel expansion to 128 analog and 112 digital channels. Programmable voltage and thermocouple measurements per channel. 10 mV to 50 V programmable range per channel in 12 steps.

  • Electrical Standards

    Fluke Calibration

    To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.

  • ESR Analyzer

    LD-LESR-A10 - Labodam

    ESR AnalyzerLD-LESR-A10is a portable unit with Westergren analysis method and infrared sensor measuring principle. It offers measurement range of 1 to 140 mm/h with throughput up to 80 samples/h. It has maximum 40 sample loading capacity at same time and two measuring time: 30 min or 60 min. Designed with touch screen large color display, built-in printer and RS232 interface. Used for analysis of erythrocyte sedimentation rate in hospitals, clinical laboratories and research.

  • ESR Analyzer

    LD-LESR-A11 - Labodam

    ESR AnalyzerLD-LESR-A11is a portable unit with Westergren analysis method and infrared sensor measuring principle. It offers measurement range of 1 to 140 mm/h with throughput up to 80 samples/h. It has maximum 20 sample loading capacity at same time and two measuring time: 30 min or 60 min. Designed with touch screen large color display, built-in printer and RS232 interface. Used for analysis of erythrocyte sedimentation rate in hospitals, clinical laboratories and research.

Get Help