  • Dual Laser InfraRed Thermometer - Wide Range IR Thermometer with Type K Input and USB interface

    Extech 42570 - Extech Instruments Corporation

    This Dual Laser Infrared Thermometer identifies the IR temperature where the dual laser converges into a single spot at approximately 50 inches from the target. Meter features fast 100 millisecond response times, Type K input, and a USB interface. Adjustable emissivity increases measurement accuracy for a variety of surfaces. Adjustable high/low set points with audible alarm alerts you when the temperature exceeds programmed set points. Featuring MAX/MIN/AVG/DIF measurements that displays the highest, lowest, average, and MAX minus MIN values. Comes complete with Type K temperature probe, USB cable and software, carrying case and 9-volt battery.

  • VFTLP+ Test System

    4012 - Barth Electronics, Inc

    The Model 4012 VFTLP+™ test system was developed in early 2000 to add high speed measurements to the usual I-V plot, to measure and record the real TDDB waveform which causes oxide failure.*Accurate measurements of this waveform have finally been identified by Barth Electronics Inc. and CDM protection can now be based on known dimensional design parameters. We identify the response of your CDM protection circuits with 100ps risetime pulses which simulate the real CDM test. This is the only way with which to provide the total gate oxide threat voltage data.*Convenient, precise, repeatable operation*Computer controlled for automated testing

  • Vector Network Analyzer

    SNA5000A - SIGLENT Technologies

    The SIGLENT SNA5000A series of Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz, with 2 and 4 port models available. Designed to give you instant insight into scattering, differential, and time-domain measurements. They are effective instrumentation for determining the Q-factor, bandwidth, and insertion loss filters and feature impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation, and adapter removal/insertion adjustments. There are five sweep types: Linear-Frequency, Log-Frequency, Power-Sweep, CW-Time, and Segment-Sweep mode. The SNA5000A series VNAs also support scattering-parameter correction of SOLT, SOLR, TRL, Response, and Enhanced Response for increased flexibility in R&D and manufacturing applications.

  • Versatile quality control testing system

    QuickSun® 550Ei - Endeas Oy

    QuickSun 550Ei is a versatile testing system for qualifying of PV modules with dimensions up to 105 x 205 cm2. Basic set up includes a top class solar simulator which measures modules in sunny side up position enabling e.g. soiling simulations. Several additional measurement methods can be integrated to the same system including high resolution EL imaging with analysis software from one of the most recognized EL system suppliers. Also hot spot revealing IR images can be recorded by applying either forward or reverse bias current, and true nA scale leakage current measurements can be performed with sensitive enough instruments.

  • 3 Phase Reference Standard

    ZERA® COM5003 - Powermetrix Systems

    The COM5003 Reference Standard is part of the ZERA/Powermetrix high precision measuring instrument series. With the highest accuracy of 0.005 % (50 ppm), the COM5003 presents its new innovative digital technology and extended features for measurement. As a primary standard, the COM5003 is designed for testing current and voltage meters as well as single- or three-phase power and energy meter testing systems. This precise technology is especially useful in metrological institutes, official utility lab applications, and other environments for energy suppliers or manufacturers of electric meters and designed for integration of existing systems. All operation, measurements and data visualizations can be viewed using by the COM5003’s simple user interface and 9“ touchscreen.

  • Modulation Distortion For E5081A Up To 20 GHz

    S960704B - Keysight Technologies

    The Keysight S960704B modulation distortion software application enables fast and accurate active device modulation distortion characterization under modulated signal conditions up to 20 GHz. The wide dynamic range and vector error correction of the ENA-X yield an extremely low residual EVM of the test setup, delivering a complete picture of your device’s signal distortion performance without test system interference. S960704B software measures EVM, NPR, ACPR, and decomposes linear and nonlinear signals by spectrally correlating input and output spectrum without needing to demodulate. Integration with the ENA-X measurement flexibility enables quick modulated signal distortion measurements along with traditional VNA tests.

  • Digital 10kV High Voltage Insulation Tester

    4310 IN - Standard Electric Works Co., Ltd

    • Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display

  • Digital 5kV High Voltage Insulation Tester

    4305 IN - Standard Electric Works Co., Ltd

    • Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 1 TΩ • 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display

  • Precision DC Power Module, 20V, 50A, 500W

    N6765A - Keysight Technologies

    The Keysight N6765A is a 500 W precision DC power module that provides low noise, and precise control and measurements in the milliampere and microampere region with the ability to simultaneously digitize voltage and current, and capture those measurements in an oscilloscope-like data buffer. This module is used in both the small, multiple output 1U high N6700 Low-Profile Modular Power System (for ATE systems) and the multiple output N6705 DC Power Analyzer (for bench testing). GPIB, LAN, USB and LXI compliance are standard. Select from more than 30 different DC power modules ranging in capability from basic to high precision, and in power from 20-500 Watts.

  • PXIe-6386, 8 AI (16-Bit, 14 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module

    785926-01 - NI

    PXIe, 8 AI (16-Bit, 14 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module - The PXIe-6386 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, four 32‑bit counters, and analog and digital triggering. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The PXIe-6386 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • PXIe-6396, 8 AI (18-Bit, 14 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module

    785927-01 - NI

    PXIe, 8 AI (18-Bit, 14 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module - The PXIe-6396 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, four 32‑bit counters, and analog and digital triggering. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The PXIe-6396 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • sbRIO-9218, Non-Enclosed, 24-Bit, 51.2 kS/s/channel, 2-Channel C Series Universal Analog Input Module

    783362-02 - NI

    Non-Enclosed, 24-Bit, 51.2 kS/s/channel, 2-Channel C Series Universal Analog Input Module - The sbRIO‑9218 helps you perform multipurpose testing. With the sbRIO‑9218, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors. You also can use the sbRIO‑9218 to perform quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. You can individually select and perform a different measurement type on each channel. Additionally, the sbRIO‑9218 features 60 VDC analog input isolation. Non-enclosed modules are designed for OEM applications.

  • NI-9361, 32-Bit, 8-Channel C Series Counter Input Module

    783407-02 - NI

    32-Bit, 8-Channel C Series Counter Input Module - The NI‑9361 is a differential or single-ended input module. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. You can also directly connect sensors with open-collector or push-pull outputs by using an internal switchable 1 kΩ pull‑up resistor. The NI‑9361 counters can perform encoder position and velocity measurements. You can synchronize the counters with other analog, digital, and counter measurements in your chassis.

  • NI-9361, 32-Bit, 8-Channel C Series Counter Input Module

    783407-01 - NI

    32-Bit, 8-Channel C Series Counter Input Module - The NI‑9361 is a differential or single-ended input module. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. You can also directly connect sensors with open-collector or push-pull outputs by using an internal switchable 1 kΩ pull‑up resistor. The NI‑9361 counters can perform encoder position and velocity measurements. You can synchronize the counters with other analog, digital, and counter measurements in your chassis.

  • PXIe-4310, 16-Bit, 8-Channel, 400 kS/s/ch, Ch-Ch Isolated PXI Analog Input Module

    784813-01 - NI

    16-Bit, 8-Channel, 400 kS/s/ch, Ch-Ch Isolated PXI Analog Input Module—The PXIe-4310 is a channel-to-channel isolated, filtered analog input module for higher voltage measurements. The module offers the ability to select an analog filter per channel to provide extra filtering performance. You also can operate up to four different input ranges per terminal block and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI-DAQmx driver simplifies hardware configuration and measurement.