Filter Results By:

Products

Applications

Manufacturers

Meters

sense, display, measures; gas, water, electricity, particles, vibration, light or quanta.

See Also: Sensors, Measurement


Showing results: 4531 - 4545 of 4858 items found.

  • 1000 Amp Clamp with IR Thermometer

    FLIR CM78 - Teledyne FLIR

    The FLIR CM78 is a True RMS industrial clamp meter for the electrician who works on high-powered equipment and temperature systems and needs a safe, capable combination tool. An integrated IR thermometer provides fast non-contact measurements on panels, conduits, and motors. FLIR Tools Mobile connects the FLIR CM78 to your compatible smartphones and tablets via Bluetooth®, and METERLiNK® technology wirelessly integrates electrical readings on your infrared image with FLIR thermal cameras.

  • Signa; Generator

    MAG-203AD - MCH Instruments Co.,Ltd.

    Features:*Signal frequency:0 .1Hz-2Mhz, continuously variable*Wave form: square,sine*Output attenuator:0dB, 20dB, 40dB,60dB*Output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*Rising and falling edge of square not more than 35ns*Sine distortion less than 1%,amplitude -frequency characterstic:±0.3dB within 100khz, ±1dB above 1Mhz*Frequency meter: 10Hz-30Mhz*Power supply : AC 220V

  • Hygro-Thermometer Psychrometer

    Extech RH300 - Extech Instruments Corporation

    The RH300 is a compact meter that is ideal for field applications. Simultaneously displays relative humidity (10% to 90% RH), air temperature and dew point or wet bulb. Calculates T1-T2 differential (air temperature minus external probe temperature) using optional probe (TP890), and T2 minus dew point. Built-in protective sensor cap. Other features include Data Hold, Auto Power Off, and MAX/MIN reading. Complete with 2 AAA batteries.

  • Tube Tester / Tube Checker

    RM 1 - Beck Elektroakustik

    Using the RM 1 Tube Checker it is immediately possible to do an exact plate current measurement without doing the often very toilsome procedures mostly necessary with classical devices. Put the electron tube, which should be measured, simply into the accordingly marked test socket, switch the equipment on, select the socket by using the rotary switch (it is indicated by a LED), wait for approx. three minutes till the tube is working stabile and read off the value on the panel meter.

  • Earth Leakage Relay

    Nippen Electrical Instruments Co.

    NIPPEN's Earth Resistance Testers are used for measuring earth electrode resistance, soil resistance, earth continuity, neutral and earth loop resistance, resistance of various components etc.They are used in Railways, Defence, Utilities, Power Plants, Geological Surveys and other Industries.Direct reading type models SET/DET/TET provide direct readings of resistance on moving coil type meters, having a linear scale, 70mm long knife edge pointer and an external zero adjustment.

  • Low Current Probe 80A

    695 - Electronic Specialties Inc.

    Great tool for accurate measurement of low current. Use with your graphing meter or lab scope to view current waveforms on fuel injectors, fuel pumps, primary ignition coils and more. Also works very well with digital multimeters. Resolution of 10 milliamps is low enough for most parasitic drain testing. In addition, the clamp opening of 1/2 inch is large enough to clamp over most negative battery cables for those parasitic drain tests.

  • FieldFox Handheld RF Analyzer, 4 GHz and 6 GHz

    N9912A - Keysight Technologies

    CAT and VNA: 2 MHz to 4/6 GHzSA: 100 kHz to 4/6 GHz Carry the world's most integrated handheld RF analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional T/R VNA, spectrum analyzer, built-in power meter, and more Save time by measuring RL and DTF simultaneously in the same sweep Calibrate simply in the field with Quick Cal Easily measure average and pulse power with a USB power sensor

  • FieldFox Handheld Microwave Analyzer, 9 GHz

    N9915A - Keysight Technologies

    9 GHz max frequency Carry the world's most integrated handheld & micro; W analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in the same sweep Simultaneously measure all four S-parameters Make accurate spectrum analyzer measurements ( 0.5 dB) without needing warm-up Calibrate simply with QuickCal

  • FieldFox Handheld RF Analyzer, 6.5 GHz

    N9914A - Keysight Technologies

    6.5 GHz max frequency Carry the world's most integrated handheld RF analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in the same sweep Simultaneously measure all four S-parameters Make accurate spectrum analyzer measurements ( 0.5 dB) without needing warm-up Calibrate simply with QuickCal

  • PDL/IL Multimeter

    PDL-201 - General Photonics Corp.

    The PDL-201 uses a patented maximum and minimum search method compliant with TIA/EIA-455-198 to simultaneously measure the Polarization Dependent Loss (PDL), Insertion Loss (IL), and optical power of devices in just 30 ms. Unlike PDL meters that use the polarization scrambling method, the PDL-201's max-min technique is useful for both low and high values of PDL. And unlike instruments that use a Mueller Matrix technique, the PDL-201 has a wide wavelength range without calibration.

  • Portable Multifunction Calibrator

    M143 - Clarke-Hess Communications Research

    The M143 Multifunction calibrator is a cost saving solution for calibration of electric meters with up to 1000 V and 20 A. It offersa basic accuracy of 0.01% in DC voltage for calibration of 3 and 4 digit multimeters. The resistance function is covered byeight fix resistors in range from 10 to 100 M. The calibrator offers TC temperature sensor simulation. It can be deliveredoptionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the unit can be usedeasily for field calibration work.

  • Frequency Shaped Isotropic Electric Probes

    PI-SH-FCC, PI-SH-ICNIRP - EMC Test Design, LLC

    An isotropic electric field probe with shaped frequency response meeting the ICNIRP or FCC RF safety standards for occupational and general public exposure limits (see the specified frequency ranges below). Meter readings are shown in % of the STD – standard reference level, eliminating the need to know the source frequency. Probe output is proportional to RF power density in the whole specified power range, producing the correct RF power measurements in single and multi-signal environments, typically present at multiple antenna sites.

  • Ionization Test Set

    PFK-105 - Prostat Corporation

    - Ionization Test Kit for Measuring Offset Voltage and Discharge Times- Includes a Field Meter, Charge Plate Monitor, ±1000 Volt Charger and Decay Timer- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Evaluate Ionizers and Packaging Materials- Includes a fixture to hold the PFM-711B, CPM-720B and PDT-740B as one- Molded Carrying Case with Foam Insert Included

  • Digital Multimeter

    MM-2 - Dwyer Instruments Inc.

    Our compact, low cost Model MM-2 Digital Multimeter with True RMS is ideal for general electrical testing and troubleshooting. This full function multimeter measures DC voltage to 1000 V and AC voltage to 750 V, DC and AC current to 10 A and resistance to 400 Ohms. In addition to volts, amps and ohms, this meter includes audible continuity, diode, LED and transistor hFE tests. The rotary switch allows you to select from any of the functions quickly and easily.

  • Economic Type Resistance Indicator

    CS1-RS - Chuan Sheng Electronics Co., Ltd.

    CS1-RS economic type Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm(2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.

Get Help