Showing results: 451 - 465 of 4968 items found.
-
Elmeasure India Pvt. Ltd
Easy navigationEvent recording with time stamp (all basic & power parameters)Unbalance load and voltage with calculated neutral currentDynamic communicationOptional digital output for all basic and power parameters
-
MPI-530-IT -
Amperis sl
Short circuit loop measurement:*impedance measurement with 23 A (44 A phase-to-phase), short circuit resistance Rzw=10Ω,*measuring range: 95...440V, frequency 45...65 Hz,
-
Meco Instruments Pvt. Ltd.,
Measures V, A, PF, Hz, KW, KVA, KVAr, Kwh, KVAh & KVArhTRMS MeasurementCan be used for Continuous MonitoringAuto / Manual Scroll Display (User Selectable)State of Art Microcontroller DesignPortable, Handy, Plug-n-Play and Easy-to-useLCD Display with BacklightRS-485 5KV Isolated Port (Optional) with MODBUS RTU Protocol (Optional)POWER MASTER Software for MIS Reports (Optional)
-
RM100 -
Macintyre Electronic Design Associa
The RM100 uses a differential measurement technique employing two subsystems to achieve its high accuracy. The first subsystem is a user controlled field neutralization unit with a dynamic range of ±100,000 nT and a resolution of 0.1 nT. The second is a low noise analog output magnetometer that measures the difference between the ambient and neutralization fields. The neutralizing field and difference field are displayed on a large Vacuum Florescent Display on the front panel. The difference field is also provided as an analog voltage through a connector on the back of the chassis. The factory calibration of the neutralization subsystem to ±0.01% is traceable to NIST.
-
-
Sper Scientific
ORP (Oxidation Reduction Potential) measures a system’s relative state for gaining or losing electrons. ORP values are affected by all oxidizing and reducing agents, not just acids and bases that influence pH measurement. In practice, ORP measures the ability of a lake or river to break down waste products, like contaminants and organic matter. When the ORP value is high, there is lots of oxygen present in the water.
-
Wuxi IMHOO Technology Co., Ltd.
1. Residual capacity of battery(Ah or mAh) 2. Capacity percentage and totem pole display 3. Battery voltage 4. Battery current 5. Power output 6. The remaining time of charging and discharging
-
burster präzisionsmeßtechnik gmbh
Developed to monitor hand lever presses. One button operation and data for different processes on PLC-slotcards allow every user quick changes of press fitting procedures. Attractive low cost device for precise quality monitoring.
-
Mk VI -
Versaperm Ltd.
Our broad range of permeability measurements instruments are at the cutting edge of technology and give precise, reliable, easy and fast result. The instruments can be configured for almost any gas or gasses, including water vapour, hydrocarbons, O2, CO2, N2, H2 and He.
-
633 -
Red Phase Instruments Australia Pty Ltd.
This instrument is designed to demonstrate the properties of phasors and real/imaginary number notation for electrical engineering students. This instrument gives the phase displacement and magnitude of the parameter under investigation. The unit has filters to eliminate harmonic distortion affecting phase angle measurement.
-
pH 705 -
Tecpel Co., Ltd.
3 1/2 Digit , Large LCD Display, Max Display 1999. Measuring Range: pH 0.01~14.00 PH. Temperature: 0.1 C~ 65 C ,Millivolt: 1mV¡ã1999m
-
MRC ltd.
* Three reading modes* Smart-Read function. More stable the reading with auto recognition end-point* Cont-Read function. It is clear to read the sample changing in measurement process* Timed-Read function. Auto timed to store the reading* Auto upgrade hardware* Power-off protection, protect your data* Remind the electrode performance and calibration.
-
-
I 520 -
LMT Lichtmesstechnik GmbH
display range 0.01 nA (last digit) to 7 999 μA4-digit display (0-7999) with dimmer for brightness controlV.24-(RS 232-) Interface, analog outputranging auto/manual or remote programmableapprox. 2.5 readings/s, attenuator 100% to 0dark current compensationpower supply for thermostatic stabilized LMT photometer headspower supply 230 V, 50-60 Hz, power cable with Euro plug
-
SX1100 -
Diamond Antenna Corp.
Frequency range:S1 (1.8-160MHz)S2 (430-450MHz/800-930MHz/1240-1300MHz)Power display range:5W/20W/200WAccuracy at full scale:±10% (F.S.)Minimum power at SWR