Model 3300TA -
Teledyne Analytical Instruments
The 3300 series of low cost, microprocessor-based instrument are specially designed to satisfy industry’s need for a simple yet highly reliable process analyzer. These units offer excellent accuracy, ease of use, high reliability, low maintenance and a variety of standard features usually found on more expensive instruments.
-
Model 3300TB -
Teledyne Analytical Instruments
The 3300 series of low cost, microprocessor-based instrument are specially designed to satisfy industry’s need for a simple yet highly reliable process analyzer. These units offer excellent accuracy, ease of use, high reliability, low maintenance and a variety of standard features usually found on more expensive instruments.
-
Model 6400TH -
Teledyne Analytical Instruments
The 6400T Series analyzers uses a proven UV fluorescence principle coupled with state-of-the-art microprocessor technology to provide accurate and dependable measurements of low level SO2. The 6400T-H2S measures hydrogen sulfide (H2S) by incorporating a catalytic converter set at 600°F (315°C) to oxidize H2S into SO2 while leaving other more difficult to oxidize sulfurs unconverted. A switching mode allows analysis of both H2S and SO2 concurrently.
-
Model 2000A -
Teledyne Analytical Instruments
The Series 2000 represents a complete line of Thermal Conductivity Detector (TCD) based analyzers which can be applied in a wide range of applications and industries. By using field proven filament-based and semiconductor based TC detectors, Teledyne is able to continuously monitor hydrogen and a variety of other gases of interest in either binary or multi-component sample gas streams.
-
Model 2000B -
Teledyne Analytical Instruments
The Series 2000 represents a complete line of Thermal Conductivity Detector (TCD) based analyzers which can be applied in a wide range of applications and industries. By using field proven filament-based and semiconductor based TC detectors, Teledyne is able to continuously monitor hydrogen and a variety of other gases of interest in either binary or multi-component sample gas streams.
-
Model 2020 -
Teledyne Analytical Instruments
The Series 2000 represents a complete line of Thermal Conductivity Detector (TCD) based analyzers which can be applied in a wide range of applications and industries. By using field proven filament-based and semiconductor based TC detectors, Teledyne is able to continuously monitor hydrogen and a variety of other gases of interest in either binary or multi-component sample gas streams.
-
Model 6400TSG -
Teledyne Analytical Instruments
The 6400TSG series utilizes our field-proven ultraviolet (UV) fluorescence technology to continuously monitor the total sulfur content found in process gas and liquid feeds. UV-Fluorescence is a non-consuming method of detection, eliminating the hassles associated with replacing tape cartridges, and enables detection as low as 10 ppb, depending on application, with stable, reproducible results.
-
Model 6400T -
Teledyne Analytical Instruments
The 6400T Series analyzers uses a proven UV fluorescence principle coupled with state-of-the-art microprocessor technology to provide accurate and dependable measurements of low level SO2. The 6400T-H2S measures hydrogen sulfide (H2S) by incorporating a catalytic converter set at 600°F (315°C) to oxidize H2S into SO2 while leaving other more difficult to oxidize sulfurs unconverted. A switching mode allows analysis of both H2S and SO2 concurrently.
-
Model 6800T -
Teledyne Analytical Instruments
The 6800T Series Analyzers are a family of on-line sequential sampling analyzers that use various automated analytical technologies to perform an analysis. When configured for alkalinity measurements, titration technology is used for the most cost effective, ease of use and low maintenance method.
-
Model 6700E -
Teledyne Analytical Instruments
Online monitoring of total organic carbon is essential for regulatory and process control purposes among water treatment, wastewater and industrial users. Teledyne’s 6700E Series employs proven UV-Persulfate methodology to isolate only organic carbons, oxidize them into carbon dioxide and measure TOC in the gas phase using infrared absorption technology. This method conforms to EPA, DIN, CE, ASTM and NAMUR regulations as well as meeting requirements of ISO and EN directives.
-
Model 6700U -
Teledyne Analytical Instruments
Teledyne’s 6700U leverages ultraviolet absorption (UVA) detection to measure for certain dissolved organic substances in water treatment and wastewater applications. Absorption of UV light at the 254 nm band is an indication of the presence of disinfection byproducts (DBPs), tri-halo methanes (TTHM) and halo-acetic acids (HAA). The 6700U provides an on-line measurement without reagents and utility gases required.
-
-
Model 7675 -
Jinan Testing Equipment IE Corporation
Designed for transverse or diametral strain measurement in environmental chambers where the entire extensometer must be exposed to elevated temperatures. These capacitive extensometers may be used up to 700 C (1300 F) without any cooling.
-
Model 3648 -
Jinan Testing Equipment IE Corporation
These extensometers use a high temperature capacitive sensor in combination with an innovative design to achieve high accuracy strain measurements in low measuring ranges not possible with other high temperature extensometers. They mount on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The overall design reduces any influence from common lab environment vibrations.The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. These units are made to order in many different gauge lengths and measuring ranges.The extensometer comes with a signal conditioner. The output is an analog DC voltage, factory calibrated with the extensometer to 0 to ±10 VDC typically. They are readily interfaced with most existing test controllers, and may be directly connected to data acquisition systems and chart recorders. Bringing the signal into a spare DC input channel (or external input) on the test controller allows the extensometer to be used for strain controlled tests like low cycle fatigue.
-
Model 3909 -
Jinan Testing Equipment IE Corporation
Designed for measuring axial displacements in the simple performance tests prescribed by NCHRP Report 465, and determining dynamic modulus of hot mix asphalt per AASHTO TP062.