  • CoaXPress Frame Grabber

    Radient eV-CXP - Matrox Imaging

    The Matrox Radient eV-CXP is a cost-effective CoaXPress (CXP) frame grabber with specific models supporting up to two (Dual) or four (Quad) simultaneous connections. By combining a field proven design with the new CXP interface, the Matrox Radient eV-CXP is a dependable high-performance image capture solution for today and into the foreseeable future. CoaXPress is a new camera interface standard that takes advantage of common coax cabling to transmit images at rates and distances above and beyond previous standards. With CXP, image data can be transmitted at up to 6.25 Gbps using a single coaxial cable and up to 25 Gbps using four cables to a maximum of 40 meters3. CXP’s high-bandwidth makes it the right match for a new generation of cameras with larger and faster image sensors.

  • CompactDAQ Chassis

    NI

    CompactDAQ Chassis feature USB, Ethernet, or WiFi connectivity and come in multiple slot counts to provide the right amount of I/O for various applications. You use these models with a combination of C Series I/O modules to create a mix of analog I/O, digital I/O, and counter/timer measurements. CompactDAQ Chassis can include multiple general-purpose counters/timers that you can access through an installed, hardware-timed digital C Series module for applications that involve quadrature encoders, PWM, event counting, pulse train generation, and period or frequency measurement. CompactDAQ Chassis also offer multiple timing engines, which allow you to run multiple hardware-timed operations simultaneously with independent rates for analog input.

  • Day/Night IP Surveillance Camera

    ENVIROMUX-IPCAM-N - Network Technologies Inc

    View and control the camera from the ENVIROMUX web interface, the camera web interface, included software, or with a compatible cell phone. With the ENVIROMUX-2D/5D/16D, a triggered snapshot can be forwarded in alert e-mails. A snapshot can be triggered by any programmed event (motion detection, door open/close, glass break, smoke, liquid detection, etc.). Image sensor: 1/4" progressive scan CMOS sensor. Video Streaming: simultaneous Motion JPEG and MPEG-4. Frame rate: 30fps at 640x480 (VGA) resolution. Lens: F2.0, 4.3 mm (0.17 in), 12 infrared LEDs for night vision. RJ45 connector. Wireless models: wireless IEEE 802.11 b/g up to 54 Mbps. Regulatory approvals: CE, FCC, RoHS.

  • Linemen's Test Set

    TeleTalker 330 - Triplett Test Equipment & Tools

    The Triplett TeleTalker™ 330 is a high performance lineman's test set with a weather resistant seal. This butt set offers many standard features not found on more expensive models like dedicated store / redial buttons, adjustable volume, Pulse and Tone dialing, and more.  The high impact and weather resistant case allows for this product to be used in all demanding industry settings and features a full 3 year warranty.  The user-friendly layout helps installers get the job done effectively with ease. The TeleTalker™ 330 requires no battery for main use and can store up to 10 frequently dialed numbers. Complete with angled bed of nails (JS Popper) test clips.

  • Open Source Computer Vision & Machine Learning Software Library

    OpenCV - Open Source Computer Vision Library

    The library has more than 2500 optimized algorithms, which includes a comprehensive set of both classic and state-of-the-art computer vision and machine learning algorithms. These algorithms can be used to detect and recognize faces, identify objects, classify human actions in videos, track camera movements, track moving objects, extract 3D models of objects, produce 3D point clouds from stereo cameras, stitch images together to produce a high resolution image of an entire scene, find similar images from an image database, remove red eyes from images taken using flash, follow eye movements, recognize scenery and establish markers to overlay it with augmented reality, etc.

  • Waveguide Electromechanical Relay Switches C, X, Ku, K & Ka Bands up to 40 GHz

    Fairview Microwave Inc.

    Waveguide Electromechanical Switch models cover C, X, Ku, K, Ka frequency bands up to 40 GHz. SPDT and Optional DPDT* Configurations with Latching Self Cut-Off Actuators, TTL Logic, and Position Indictors with manual override. Patented Motor Drive with Arc Suppression. Designs support WR-137, WR-112, WR-90, WR-75, WR-62, WR-42, and WR-28 waveguide sizes with O Rings for pressurized operation. Power handling capability up to 12 kW CW and 320 kW Peak. These waveguide electromechanical relay switches deliver desirable performance that includes high isolation levels up to 105 dB, and extremely low insertion loss down to 0.01 dB.

  • Wireless Day/Night IP Surveillance Camera

    ENVIROMUX-IPCAM-WN - Network Technologies Inc

    View and control the camera from the ENVIROMUX web interface, the camera web interface, included software, or with a compatible cell phone. With the ENVIROMUX-2D/5D/16D, a triggered snapshot can be forwarded in alert e-mails. A snapshot can be triggered by any programmed event (motion detection, door open/close, glass break, smoke, liquid detection, etc.). Image sensor: 1/4" progressive scan CMOS sensor. Video Streaming: simultaneous Motion JPEG and MPEG-4. Frame rate: 30fps at 640x480 (VGA) resolution. Lens: F2.0, 4.3 mm (0.17 in), 12 infrared LEDs for night vision. RJ45 connector. Wireless models: wireless IEEE 802.11 b/g up to 54 Mbps. Regulatory approvals: CE, FCC, RoHS.

  • 4-Way Power Splitter/Combiner

    ZN4PD1-183W+ - Mini-Circuits

    Mini-Circuits’ ZN4PD1-183W+ is a 4-way 0˚ splitter/combiner covering a wide range of applications from 4000 to 18000 MHz including test and measurement, EW, SatCom and more. This model is capable of handling up to 30W RF input power as a splitter and passing up to 4A DC current from the sum port to alloutput ports (100mA each port). Its outstanding combination of high power and low loss minimize intrinsic losses and provide excellent signal fidelity from input to output. It also provides high port-to-port isolation, excellent VSWR and low amplitude and phase unbalance. It comes housed in a rugged aluminum alloy case with SMA connectors at all ports.

  • Vector Network Analyzer Extenders

    VNAX - Virginia Diodes, Inc.

    VDI''s VNA Extenders deliver high performance network analyzer frequency extension into the THz range. Models cover 50 GHz to 1,100GHz with additional bands in development. VDI modules come in a variety of form factors and configurations including our original Standard-size Modules and new Mini Modules that reduce volume up to 75%. In addition to our full Transceiver (TxRx) modules, VDI also offers Transmit-Reference (TxRef) modules and Receive only (Rx) modules that deliver optimized performance for specific applications. These modules combine high test port power and exceptional dynamic range to deliver industry leading performance. They are compatible with most network analyzers and can be integrated into probe stations and antenna chambers.

  • Carbon Dioxide Meters

    PCE Instruments

    A carbon dioxide meter warns optically or acoustically when the carbon dioxide content is critical. Depending on the model, the carbon dioxide meter supports the function of switching relays when an adjusted value is exceeded. This function can help with the automatic conditioning of rooms. The auto calibration function of the carbon dioxide meter makes an easy calibration possible.The carbon dioxide meter supports the function of data storage and further data transfer of measuring results to a computer. Therefore, it is possible to take long-term measurements in order to capture the carbon dioxide content of a specific place for a longer period. Also, you can find a carbon dioxide meter for fixed installations. These can be applied individually or connected to a gas warning system.

  • SC-1 Monitor

    CS-131 - HORIBA, Ltd.

    The CS-131 is a high-precision chemical concentration monitor designed for use with SC-1 solutions used in cleaning processes during semiconductor manufacturing. It offers a faster response speed in a more compact size than anything available to date. The CS-131 monitors the concentrations of the individual components of the SC-1 solutions (NH3/H2O2/H2O) which is widely used to remove particles and organic substances. The monitor has a number of outputs which can be utilized to keep the concentrations of the individual elements of the SC-1 solutions within the allowable ranges; this eliminates unnecessary replacement of chemicals potentially increasing bath life time and reducing chemical cost. In addition, a model with an integrated cooling unit is available, allowing accommodation of a broader range of sample temperatures.

  • EHC-09 Ultrasonic Corrosion Thickness Gage - Monochrome

    EHC-09 - Danatronics Corporation

    Danatronics most popular thickness gages are those in our EHC-09 series. With thousands of units in the field, our durable, custom molded case with raise rubber keypad is IP54 rated and has proven it can handle your toughest jobs (this is bad help fix). The EHC-09 series is available in 6 models to suit every budget and application. What’s best is our simple upgrade path where all gages are capable of quickly and easily (directly from the keypad) adding any software options. Features include a graphic display with multiple languages, vibrate on alarm, fast minimum, echo to echo to ignore coatings, 100K reading Datalogger with export to excel, B-scan and live A-scan with waveform adjust.

  • Micro-Ohmmeters

    IBEKO Power AB

    Contact resistance measurement is one of the most important and common tests during switchgear manufacturing, commissioning and maintenance stages. Besides switchgear testing, the RMO digital micro-ohmmeters are designed for simple, safe and efficient testing of:disconnecting switches,high-current bus bar joints,cable splices,welding joints,and different high-current links in factory and high-induction field environments.All DV Power RMO micro-ohmmeters use Kelvin’s 4-point measurement principle which is the most convenient for very small resistance measurements. The measurements are accurate and in accordance with international standards for AC high-voltage circuit breakers testing (IEEE C37.09 and IEC 62271-100).Starting from 2003, DV Power has been a trend-setter on the market when our first 500 A micro-ohmmeter weighing only 8 kg (RMO500A / CPM500) was released.Currently, DV Power products portfolio includes 16 models, divided into 3 series:13 portable models: RMO-A (6) and RMO-G (7) series.6 handheld models: RMO-H (6) seriesThe instruments generate a user-selectable and ripple-free test current up to 800 A in an automatically regulated test ramp. Test current ramping significantly decreases the influence of the magnetic transients to measurement.

  • Protective Bonding Testers

    RMO-E Series - IBEKO Power AB

    The RMO-E instruments are designed and ideal for testing protective bonding (grounding) of equipment following the standard IEC 61010-1. Also, they can measure the resistance of high, middle and low voltage circuit breakers, high-current bus bar joints, cable splices, and welding joints. The instruments accurately measure not only in factory environments but also in high-induction fields and substations.Both models generate a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the protective bonding testers automatically generate increasing current before measuring and decreasing current after the measurement. Consequently, this significantly decreases magnetic transients and ensures great accuracy.These instruments can store up to 500 measurements in the internal memory and have a built-in thermal printer available as an option.DV Win software communicates with the RMO-E earth resistance meter via USB or RS232 interface. It allows a user to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.The RMO-E series contains two models, RMO60E and RMO100E. The main difference between these two models is in the maximal test current:60 A DC for RMO60E100 A DC for RMO100E

  • 2-Ch Sensor Amplifier

    SR-2210 - Ono Sokki

    The SR-2210 sensor amplifier accepts constant-current line drive sensors and connects the signal to analyzers and recorders that would not otherwise be compatible with constant-current sensors.The units connects directly with BNC connectors to ONO's model MI-3111 microphone preamplifiers and NP-3000 series of accelerometers.With compact, light-weight, battery operation, it can save for preparation of measurement.