  • GPIB to Ethernet to Instrument Interface

    Model 4865B - ICS Electronics

    * Adds a GPIB Interface to Instruments with a VXI-11 or Raw Socket Ethernet Interface.* Transparent data transfer handles ASCII and binary data.* Controllable with any IEEE-488.2 GPIB Controller* VXI-11 protocol supports control, abort and reverse channels.* Raw Socket protocol includes substitute command strings for GPIB Device Trigger, Device Clear and Interface Clear.* Auto-Find feature simplifies instrument linkage* Reuses existing test software with new Ethernet instruments.* Easy configuration with the 4865B's internal webserver.* Drop in replacement for the original Model 4865 with 2x to 5x speed increase.* 1 U high rack mount kit mounts one or two 4865Bs.* Includes universal 115/230 VAC Power Adapter.

  • 1100-Channel GSM Channelizer wih Quad A/D - PCIe

    Model 78663 - Pentek, Inc.

    Model 78663 is a member of the Cobalt® family of high-performance PCIe boards based on the Xilinx Virtex-6 FPGA. This fourchannel, high-speed A/D converter with1100 GSM DDCs (digital downconverters) accepts IF signals from an RF tuner. It is ideal for capturing all transmit and receive signals in both upper and lower GSM bands.

  • 4-Channel 200 MHz A/D with DDC, Virtex-6 FPGA - PCIe

    Model 78661 - Pentek, Inc.

    Model 78661 is a member of the Cobalt® family of high performance PCIe boards based on the Xilinx Virtex-6 FPGA. A multichannel, high-speed data converter withprogrammable DDCs (digital downconverters), it is suitable for connection to HF or IF ports of a communications or radar system. Its built-in data capture feature offers an ideal turnkey solution.

  • Cryogenic Probe Station

    Model EMPX-HF - Lake Shore Cryotronics, Inc.

    The Model EMPX-HF is a versatile cryogenic electromagnetbased micro-manipulated probe station used for nondestructive testing of devices on full and partial wafers up to 25 mm (1 in) in diameter.

  • Cryogenic Probe Station

    Model CPX-VF - Lake Shore Cryotronics, Inc.

    The Model CPX-VF is a versatile cryogenic micromanipulated probe station used for non-destructive magnetic testing of devices on full and partial wafers up to 51 mm (2 in) in diameter.

  • High Temperature XY Planar Biaxial Extensometer 1200 C or 1600 C)

    Model 7651 - Jinan Testing Equipment IE Corporation

    Model 7651 extensometers measure combined in-plane strains in flat cruciform specimens tested in machines capable of simultaneous X and Y (perpendicular) axial loading and on standard flat samples tested in pure tension. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7651 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to eliminate crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃(2900°F) high temperature option.

  • Chemiluminescence 03 Analyzer

    Model T265 - Teledyne Advanced Pollution Instrumentation

    The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemilumescence with Nitric Oxide (NO) as a reagent, making is safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, including the avoidance of positive and commonly found interferrents such as VOCs, fine particulates, Mercury, turpines, ClO2, and others. If these pollutants are present in the atmosphere, it can cause UV absorption analyzers to give an artificially high Ozone measurement. The innovative T265 combines speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.

  • Ethernet to GPIB Controller

    Model 8065 - ICS Electronics

    * Controls GPIB Devices anywhere there is a network or internet connection.* No special driver required which eliminates driver problems.* Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls.* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* VXI-11 compliant.* Includes ICS's VXI-11 and VISA keyboard control programs.* Works with Agilent, NI and Kikisui VISA libraries.* Internal webserver lets you change network settings from any browser.* Network connectivity eliminates GPIB Bus Extension problems.* Allows multiple users to access the GPIB instruments.* 8065 is our original Ethernet to GPIB Controller and recommended for replacement purposes with existing programs. Use the Model 9065 for new applications.

  • Spectrometer

    Model 207 - McPherson, Inc.

    The Model 207 offers the user the most throughput and fastest aperture in a long focal length monochromator. This is ideal for photoluminescence and Raman spectroscopy applications. It is also available in a vacuum compatible version. Used in air and with a selection of gratings, the spectral range of the 207 extends from 185 nanometersm to 20 microns or more. Under vacuum range is extended down to 105 nm (depends on the grating.) Multiple ports are available for mounting accessories or CCD detectors, etc. McPherson SNAP IN gratings allow the alignment-free use of many different gratings. Easily view a wider spectral range or obtain higher resolution! You can retrofit years later and not have to worry about alignment with the McPherson SNAP IN approach. Our dual grating turret also accepts these easy to exchange gratings.

  • Trace-Level UV Fluorescence SO2 Analyzer

    Model T100U - Teledyne Advanced Pollution Instrumentation

    The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.

  • Calibration & Demag.

    Model 8515-D - Magnetic Instrumentation Inc.

    The Model 8515-D is a medium-energy, high voltage, and capacitor discharge type ringing demagnetizer capable of desaturating Ceramic and Rare Earth magnetic materials. The Model 8515-D is easily adapted to a wide range of production and laboratory demagnetizing requirements. A modern solid-state electronic control circuit, coupled with a rugged, heavy-duty discharge SCR and fixture, make this demagnetizer a highly reliable, low maintenance unit. The electronic voltage control circuit prevents the Model 8515-D from being discharged before the preset energy level has been reached, avoiding incomplete magnet desaturation. An easy to read front panel meter monitors the capacitor voltage. The energy storage level can be easily changed in the field. Integral electrical interlock and fail-safe circuitry provide a high degree of operator safety.

  • 1-Chan 3.6 GHz or 2-Chan 1.8 GHz 12-bit A/D with Virtex-6 FPGA - PCIe

    Model 78640 - Pentek, Inc.

    Model 78640 is a member of the Cobalt® family of high performance XMC modules based on the Xilinx Virtex-6 FPGA. A highspeed data converter, it is suitable forconnection to HF or IF ports of a communications or radar system. Its built-in data capture features offer an ideal turnkey solution as well as a platform for developing anddeploying custom FPGA processing IP.

  • High-Voltage Amplifier

    Model 30/20A - TREK, INC.

    The Model 30/20A is a DC-stable, high-voltage power amplifier designed to provide precise control of output voltages in the range of 0 to ±30 kV DC or peak AC with an output current range of 0 to ±20 mA DC or peak AC. The amplifier is configured as noninverting with a fixed gain of 3000 V/V. Inverting and differential input options are available. A calibrated potentiometer provides a DC offset over a range of 0 to ±30 kV DC.

  • Oxygen Transmitter​​​​​​

    Model InstaTrans-XD​​​ - Teledyne Analytical Instruments

    This model utilizes a design to meet the requirements of NEMA-4(IP-66) levels as well as ATEX Zone 0/1/2 and FM/FMc Class I Div 1 approvals when used with select intrinsic safety barriers. In addition, the CSA approval extends to Class I Div 2 as a non-incentive device without the use of barriers. The transmitter head contains the electronics and user display interface including 4-button design to access functions.

  • 1 GHz A/D and D/A with Virtex-7 FPGA - XMC

    Model 71730 - Pentek, Inc.

    - Complete radar and software radio interface solution- Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- One 1 GHz 12-bit A/D- One 1 GHz 16-bit D/A- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- Dual uSync clock/sync for multimodule synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8 wide- VITA 42.0 XMC compatible with switched fabric interfaces- Optional user configurable gigabit serial interface- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to four modules with Model 7192 System Synchronization and Distribution Amplifier - PMC/XMC- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount