Filter Results By:

Products

Applications

Manufacturers

Model

construction of a concept.

See Also: Modeling, Modelling, Modelers, Human Body Model, Charged Device Model


Showing results: 571 - 585 of 4104 items found.

  • 4-Channel 200 MHz A/D with DDC, Kintex UltraScale FPGA - XMC

    Model 71861 - Pentek, Inc.

    - Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Complete radar and software radio interface solution- Supports Xilinx Kintex UltraScale FPGAs- Four 200 MHz 16-bit A/Ds- Four multiband DDCs (digital downconverters)- 5 GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multimodule synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- VITA 42.0 XMC compatible with switched fabric interfaces- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • 3-Channel 200 MHz A/D and 2-Channel 800 MHz D/A with Virtex-7 FPGA - XMC

    Model 71720 - Pentek, Inc.

    - Complete radar and software radio interface solution- Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- Three 200 MHz 16-bit A/Ds- One digital upconverter- Two 800 MHz 16-bit D/As- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multimodule synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- VITA 42.0 XMC compatible with swtiched fabric interfaces- Optional user configurable gigabit serial interface- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • 4-Channel 1.25 GHz, 16-bit D/A with Virtex-6 FPGA - 3U VPX

    Model 52670 - Pentek, Inc.

    - Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Four 1.25 GHz 16-bit D/As- Four digital upconverters- Programmable output levels- 250 MHz max. output bandwidth- 2 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- Dual µSync clock/sync bus for multimodule synchronization- User-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- 3U VPX form factor provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount

  • 1-Ch. 6.4 GHz or 2-Ch. 3.2 GHz A/D, 2-Ch 6.4 GHz D/A Kintex UltraScale - PCIe

    Model 78141 - Pentek, Inc.

    Model 78141 is a member of the JadeTM family of high-performance PCIe boards. The Jade architecture embodies a new streamlined approach to FPGA-based boards, simplifying the design to reduce power andcost, while still providing some of the highest-performance FPGA resources available today. Designed to work with Pentek’s new NavigatorTM Design Suite of tools, the combination of Jade and Navigator offers users an efficient path to developing and deployingFPGA-based data acquisition and processing. The 78141 is a high-speed analog-to-digital and digital-to-analog converter with programmable DDCs (digital downconverters) and DUCs (digital upconverters). It is suitable for connection to HF or IF ports of a communications or radar system. Its built-in data capture and generator features offer an ideal turnkey solution as well as a platform for developing and deploying custom FPGA-processing IP.

  • Hydraulic Component Test Stand

    Model 700 - Power Test, Inc.

    Model 700 Hydraulic Component Test Stand (HCTS). Designed to test heavy-duty, off-highway, closed or open loop pumps, the 700 gives you the capacity to confidently and efficiently verify the quality of your work. Test new or rebuilt pumps, motors, valves, and cylinders independently, and communicate their quality to your customers with the help of PowerNet TD, data acquisition software for transmission and hydraulic systems. Convenient work height with adjustable mounting track. 100, 200 or 300 HP drive motor options available. Variable Frequency Drive (VFD) controlled drive motor. 200 gallon (757 L) high-mount hydraulic oil reservoir for flooded pump supply. Combined kidney filtration and cooling loop for continuous cleaning. Thermostatically controlled cooler and 7 kW reservoir immersion heater.

  • OnyxFX FlexorSet 4-Ch. 250 MHz A/D w/DDCs, 2-Ch. 800 MHz D/A w/DUC, Int - 3U VPX

    Model 5973-313 - Pentek, Inc.

    - Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- Four 250 MHz 16-bit A/Ds- Four multiband DDCs- One digital upconverter- Two 800 MHz 16-bit D/As- Extended Interpolation- Sample clock synchronization to an external system reference- PCI Express (Gen. 1, 2 and 3) interface up to x8- User-configurable gigabit serial interface- Optional optical Interface for backplane gigabit serial interboard communication- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- Compatible with several VITA standards including: VITA-46, VITA-48 AND VITA-66.4 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- See comparable JadeFX Xilinx Kintex UltraScale FPGA Family:- Model 5983 JadeFX Kintex UltraScale Processor and FMC Carrier 3U VPX- Model 5983-313 JadeFX FlexorSet 4-Ch. 250 MHz A/D w/DDCs, 2-Ch. 800 MHz D/A w/DUC, Int - 3U VPX

  • Heliodons

    betanit.com

    The heliodon is a device to evaluate the performance of a model under clear sky. The model can be a scale model of windows to a part of a building or a part of urban environment.

  • UV Absorption O3 Analyzer​​​

    Model N4​00 - Teledyne Advanced Pollution Instrumentation

    The Model N400 Ultraviolet (UV) Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air. A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone. The result is a true, stable ozone measurement.

  • Vacuum Leak and Holiday Detectors

    Electro-Technic Products, Inc.

    Electro-Technic manufactures four handheld models (BD-10, BD-40, BD-50, BD-60) and a customizable automated model (Model BD-65) to suit specific customer applications and test materials. Our introductory BD-10 model is intented for light/intermittent use while our BD-50/BD-60 models are more suited for continous heavy duty use. Our model BD-40 has a limited voltage output suited for thin/sensitive linings.

  • Bolt Extensometers for Proof Load Testing

    Model 3565 - Jinan Testing Equipment IE Corporation

    The Model 3565 uses hard conical points to contact the bolt at the center of the head and at the bottom. It is fully adjustable for different length bolts ranging from 25 mm (1 inch) in length to 150 mm (6 inches) standard. Extension beams are available for longer bolts. The standard maximum measuring range is 1.25 mm (0.05 inches). Generally, on longer bolts this extensometer will be self-supported without requiring any centering marks or punch marks on the bolt. For shorter bolts these marks may be required. If the conical pins are sharp, marks are often not needed even on the shortest bolts.The extensometer has a zero adjustment screw to adjust the length between the contact pins. This is used to set the output voltage to zero, which corresponds to the correct starting position for the test. It also includes a breakaway lower arm. In the event a bolt should fail, the breakaway arm snaps free, helping to prevent damage to the extensometer. This is easily re-installed. In the event that bolt failures are likely during a test, it is recommended the user attach a cord around the upper part of the beam and tie the other end to the test frame to prevent the extensometer from falling. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 3565 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • OnyxFX FlexorSet 4-Ch 16-bit: 500 MHz A/D & 2 GHz D/A - PCIe

    Model 7070-324 - Pentek, Inc.

    The FlexorTM Model 3324 is a multichannel, high-speed data converter FMC. Itis suitable for connection to HF or IF ports of a communications or radar system. It includes four 500 MHz, 16-bit A/Ds, four 2 GHz, 16-bit D/As, programmable clocking, and multi-board synchronization for support of larger high-channel count systems. When combined with a Pentek 3U VPX or a PCIe FMC carrier, the 3324 is available as a FlexorSet, a complete turnkey data acquisition solution.

  • High-Voltage Power Amplifier

    Model 40/15 - TREK, INC.

    The Model 40/15 is a DC-stable, high-voltage power amplifier featuring an all solid-state design for high slewrate, wide bandwidth, and low-noise operation. It is configured as noninverting with a fixed gain of 4000 V/V and is protected against overvoltage and overcurrent conditions that may be generated by active loads or by output short circuits to ground. Precision voltage and current monitors provide low-voltage representations of the high-voltage output and load current for monitoring purposes or for use as feedback signals in a closed-loop system.

  • Load Cell Amplifier Signal Conditioner with DB9 Connectors

    MODEL LCA-9PC - Transducer Techniques, Inc

    The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Load Cell Amplifier Signal Conditioner with Removeable Terminals

    MODEL LCA-RTC - Transducer Techniques, Inc

    The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • 2-Ch 3.6 GHz or 4-Ch 1.8 GHz 12-bit A/D with DDC, Kintex UltraScale - 6U VPX

    Model 58841 - Pentek, Inc.

    - Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Ideal radar and software radio interface solution- Supports Xilinx Kintex UltraScale FPGAs- One-channel mode with two 3.6 GHz, 12-bit A/D- Two-channel mode with four 1.8 GHz, 12-bit A/D- Programmable DDCs (Digital Downconverter)- 10 GB of DDR4 SDRAM- µSync clock/sync for multiboard synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount

Get Help