Showing results: 511 - 525 of 723 items found.
-
U2351A -
Keysight Technologies
The U2351A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. With the analog output being able to send out predefined or arbitrary waveforms make this a good tool when closed loop feedback or stimulus is required. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2351A to simulate simultaneous analog input acquisition.
-
U2356A -
Keysight Technologies
The U2356A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. With the analog output being able to send out predefined or arbitrary waveforms make this a good tool when closed loop feedback or stimulus is required. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2356A to simulate simultaneous analog input acquisition.
-
781345-01 -
NI
102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4331 is a high-speed input module that provides integrated data acquisition and signal conditioning for dynamic strain, load, and pressure measurements. This module includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4331 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4331 provides remote sensing, internal bridge completion, and shunt calibration options per channel.
-
M9022A -
Keysight Technologies
The M9022A is a PXIe System Module and is installed in the system slot of a PXIe chassis. When combined with an appropriate host adapter, it will provide a high data BW connection between the host PC and the chassis. The module can also be used with an M9037A PXIe embedded controller to interconnect two chassis in a multi-chassis system.
-
cPCI-R6002 Series -
ADLINK Technology Inc.
The cPCI-R6002 Series is a 6U CompactPCI rear transition module (RTM) in single/dual slot width (4/8HP) form factor featuring rich IO interfaces. The single slot cPCI-R6002 supports 2x GbE, 2x USB 2.0, 1x DB-9 COM, and 1x DVI-I on the rear panel. The dual slot cPCI-R6002D supports 2x GbE, 4x USB 2.0, 1x DB-9 COM, 1xDVI-I, PS/2 KB/MS, and audio ports on the rear panel. For storage, the cPCI-R6002 provides 2x 7-pin SATA connectors and the cPCI-R6002D offers an additional 2.5" SATA drive space via daughter board. Onboard IO includes 1x 5-pin USB pin header and 1x 10-pin serial TX/RX pin header.
-
-
42-412A-024 -
Pickering Interfaces Ltd.
The 40-412A-024 (PXI) and 42-412A-024 (PXIe) are 16-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
40-412A-024 -
Pickering Interfaces Ltd.
16-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
40-414-101 -
Pickering Interfaces Ltd.
The 40-414-101 (PXI) and 42-414-101 (PXIe) are 128-channel digital input modules with 50 V inputs and provide a convenient way of determining the status of input lines by comparing the input voltage with two threshold voltages - quickly establishing if the input is low, high or in an intermediate logic state.
-
42-414-101 -
Pickering Interfaces Ltd.
The 40-414-101 (PXI) and 42-414-101 (PXIe) are 128-channel digital input modules with 50 V inputs and provide a convenientway of determining the status of input lines by comparing the input voltage with two threshold voltages - quicklyestablishing if the input is low, high or in an intermediate logic state.
-
ND-6060 -
ADLINK Technology Inc.
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
HMNS AXIe-0 -
Holding Informtest
The HMNS AXIe-0 module is a carrier of mezzanine modules made in the AXIe-0 standard. The module ensures the functioning of various modules installed in it, made in the form of mezzanines. The HMNS AXIe-0 module is intended for use as a carrier of mezzanines in multichannel systems for collecting/issuing information of both digital and analog types.
-
NMNS AXIe-0 -
Holding Informtest
NMNS AXIe-0 module is a carrier of mezzanine modules made in the AXIe-0 standard. The module ensures the functioning of various modules installed in it, made in the form of mezzanines. The NMNS AXIe-0 module is intended for use as a mezzanine carrier in multichannel systems for collecting / issuing information, both digital and analog.
-
NMU AXIe-0 -
Holding Informtest
NMU AXIe-0 is a carrier of mezzanine modules made in the AXIe-0 standard. The module ensures the functioning of various modules installed in it, made in the form of mezzanine modules (mezzanines). NMU AXIe-0 is intended for use as a mezzanine carrier in multichannel systems for collecting / issuing information, both digital and analog.
-
VXI NMU -
Holding Informtest
NMU is a carrier of mezzanine modules in the VXI standard, it is a VXI module of size C-1. The NMU ensures the functioning of various modules installed in it, made in the form of mezzanines. NMU is intended for use as a mezzanine carrier in multichannel systems for collecting / issuing information, both digital and analog.