Showing results: 2086 - 2100 of 10234 items found.
-
41-760-002 -
Pickering Interfaces Ltd.
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
41-760-001 -
Pickering Interfaces Ltd.
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
41-760-003 -
Pickering Interfaces Ltd.
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
41-760-004 -
Pickering Interfaces Ltd.
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 26 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
Pickering Interfaces Ltd.
Pickering's PXI medium power general purpose switch modules offer higher current ratings in a single 3U slot. The relay solutions have been carefully chosen to ensure a long service life. All the connectors used are fully supported by our cable and connector accessories to simplify system integration.
-
SenseNet CAN -
Cubic Systems, Inc.
The award winning SenseNet Telematics Module features all of the connectivity required to implement powerful and inexpensive Telematics solutions for military and commercial vehicle applications. SenseNet is currently in use in commercial and military vehicle applications requiring both wired and unwired sensor network connectivity and support in Condition Based Maintenance projects.
-
SolsTiS ECD-X-Q -
M Squared Lasers
SolsTiS ECD-X Q extends the range of the SolsTiS platform into the deep UV providing unrivalled power and tuning. SolsTiS ECD-X-Q is used in combination with the ECD X doubling cavity (wavelength ranges between 210–250 nm) or the EMM mixing module (wavelength ranges between 250–300 nm).
-
PXI-7901 -
ADLINK Technology Inc.
ADLINK PXI-7901 is a general-purpose (GP) switch module implementing 16-CH independent single-pole double-throw (SPDT) relays (1 Form C). PXI-7901 can connect one input to one output and be used as signal switching and routing for measurement system or ATE. Thanks to its high switching capacity, PXI-7901 can also be used to turn on or turn off devices such as motors, fans, heaters, and lights. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7901, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
40-527-001 -
Pickering Interfaces Ltd.
The 40-527, 40-528A and 40-529A are PXI single-pole matrices each supporting 128 cross points. The modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.
-
40-166-101 -
Pickering Interfaces Ltd.
The 40/42-166-101 is a PXI/PXIe high density power relay module with 6xSPDT switches rated at 20A. The 40/42-166 range is available with SPST, SPDT or SP4T switching configurations. It uses power relays which are suitable for switching loads up to 20A at 240VAC (SPDT & SP4T versions) or 30A at 277VAC (SPST versions).
-
40-166-201 -
Pickering Interfaces Ltd.
The 40/42-166-201 is a PXI/PXIe high density power relay module with 3xSP4T switches rated at 20A. The 40/42-166 range is available with SPST, SPDT or SP4T switching configurations. It uses power relays which are suitable for switching loads up to 20A at 240VAC (SPDT & SP4T versions) or 30A at 277VAC (SPST versions).
-
40-166-002 -
Pickering Interfaces Ltd.
The 40/42-166-002 is a PXI/PXIe high density power relay module with 5xSPST switches rated at 30A. The 40/42-166 range is available with SPST, SPDT or SP4T switching configurations. It uses power relays which are suitable for switching loads up to 20A at 240VAC (SPDT & SP4T versions) or 30A at 277VAC (SPST versions).
-
40-166-102 -
Pickering Interfaces Ltd.
The 40/42-166-102 is a PXI/PXIe high density power relay module with 3xSPDT switches rated at 20A. The 40/42-166 range is available with SPST, SPDT or SP4T switching configurations. It uses power relays which are suitable for switching loads up to 20A at 240VAC (SPDT & SP4T versions) or 30A at 277VAC (SPST versions).
-
40-166-202 -
Pickering Interfaces Ltd.
The 40/42-166-202 is a PXI/PXIe high density power relay module with 2xSP4T switches rated at 20A. The 40/42-166 range is available with SPST, SPDT or SP4T switching configurations. It uses power relays which are suitable for switching loads up to 20A at 240VAC (SPDT & SP4T versions) or 30A at 277VAC (SPST versions).
-
40-166-001 -
Pickering Interfaces Ltd.
The 40/42-166-001 is a PXI/PXIe high density power relay module with 10xSPST switches rated at 30A. The 40/42-166 range is available with SPST, SPDT or SP4T switching configurations. It uses power relays which are suitable for switching loads up to 20A at 240VAC (SPDT & SP4T versions) or 30A at 277VAC (SPST versions).