Showing results: 3526 - 3540 of 10234 items found.
-
M9024A -
Keysight Technologies
The M9024A is a PXIe System Module and is installed in the system slot of a PXIe chassis. When combined with an appropriate host adapter, it will provide a high data BW connection between the host PC and the chassis. The M9024A has a flexible configuration capability. Each card has two Gen 3 x8 PCIe cable links capable of achieving speeds up to 8 GB/s on each port. These two ports can be combined into a single x16 cable link providing a speed of up to 16 GB/s. This means a data-intensive system can be built using high-performance desktop or rack-mounted computers.
-
DP-cPCI-4032 -
Data Patterns Pvt. Ltd.
DP-cPCI-4032, is a hot swappable high density 192x1 or 96x2 relay scanner module. DP-cPCI-4032 is implemented as a 6U cPCI module.The 96 channel scanner is divided into six banks of 16x2 scanner. The banks are isolated from each other using tree switches. Six tree switches are used, one tree switch for each bank. A common tree switch is used to group all the six banks. Depending on the application requirement, it can be configured as 96 x 2 or 192 x 1 scanner. For short circuit protection, resistors are provided for all the common terminals.
-
510151124 -
Virginia Panel Corporation
NOTE: Part # 510151124 Rev D and higher utilize captive screws that cannot be replaced with screws from currently VPC- offered screw kits.Primary mating module 510150115. (May mate with other Receiver modules, as well.)
-
DAQ973MBX -
Keysight Technologies
The DAQ973MBX Best Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe, three 20-channel DAQM901A multiplexer modules, and a BV0006B BenchVue DAQ software with a KeysightCare software support subscription. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2-and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning measures thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance36-month node-lock BV0006B BenchVue DAQ software license with KeysightCare software support subscription
-
780173-01 -
NI
±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.
-
785184-01 -
NI
±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.
-
779357-01 -
NI
±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.
-
784277-01 -
NI
1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module—The PXIe‑4480 is designed for high-bandwidth audio, acoustic, and vibration measurements. It provides six channels of dynamic signal acquisition, and you can use one of four gain settings to configure your input range. The PXIe‑4480 also includes software-configurable AC/DC coupling, charge measurement, voltage excitation, IEPE excitation, and TEDS support, making it ideal for measuring acoustic transducers, pressure sensors, and hydrophones. Common applications include audio test; noise, vibration, and harshness (NVH) analysis; and underwater acoustic measurements. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4480 can sample up to 20 MS/s per channel in time-domain mode.
-
EDL-mPCIe-MA2485 -
ADLINK Technology Inc.
The EDL-mPCIe-MA2485 PCIe mini-card features Intel® Movidius™ Myriad™ X VPU, providing an easy and flexible solution for computer vision and deep learning acceleration. Able to solve complex AI hardware design challenges, it enables integration of vision-based accelerators and inference engines to implement deep learning solutions at the edge.
-
CEM130 -
Axiomtek Co., Ltd.
*AMD Ryzen™ Embedded V1000 processors*2 DDR-2400/3200 SO-DIMM for up to 32GB of memory*Max. up to 7 lanes of PCI Express*2 SATA-600*3 USB 3.0 and 8 USB 2.0*TPM 2.0 supported*Wide voltage input from +8V to +20V
-
GLSUN-DWDM -
Guilin GLsun Science and Tech Group Co., LTD
Wavelength ITU channels 186.6 to 196.1 THz Return Loss ≥ 45 dBDirectivity ≥ 50 dB Connector LC/PCMax. Optical Power ≤ 500 mW PDL ≤ 0.15 dBRelative Humidity 5%~ 95% Dimension 100×80×10.5 mmOperating Temperature -10℃ to +70℃ Storage Temperature -40℃ to +85℃
-
610102117 -
Virginia Panel Corporation
Primary mating contact 610102116. (May mate with other ITA contacts, as well.)20 GHz coax contacts have an impedance of 50 Ohms and a current rating of 5 amps.It is recommended to use SF142 to achieve 20 GHz and RG223 to achieve 12 GHz.
-
779001-01 -
NI
4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input ModuleThe NI‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
JX/256-MF -
Cytec Corp.
These Chassis control up to 16 modules with as many as 32 two pole relays per module allowing 1xN multiplexers up to 1020x1, 2 pole muxes up to 512x1 or 2xN matrix configurations up to 256x2. Jumpering option allow the modules to be controlled as separate smaller muxes, i.e. 64 4x1 2 pole muxes, or combine specific groups to allow an almost unlimited combination of sizes. Add a Control Module and optional manual control to complete the system.
-
782357-01 -
NI
40 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2797 offers a high-density, terminated multiplexer with dual 6x1 multiplexer banks in the same module. The internal termination of the PXI‑2797 helps prevent high-power reflections that arise from open channels on the module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules.