Filter Results By:

Products

Applications

Manufacturers

Showing results: 7846 - 7860 of 10234 items found.

  • Accessories

    ROCON

    This group of devices comprises of I/O modules, auxiliary power supply, interface converters, optical heads, interface cables, temperature sensors, transducers etc.

  • PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode, 9/125 Fiber, MU Connectors

    42-850A-314 - Pickering Interfaces Ltd.

    The 40/42-850A-314 is a PXI/PXIe 4-channel multiplexer with MU (mini SC) connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.

  • VXT PXI Vector Transceiver, 300/600/1200 MHz Bandwidth

    M9410A - Keysight Technologies

    The Keysight M9410A VXT PXIe vector transceiver integrates a 6 GHz vector signal generator and vector signal analyzer in a 2-slot PXIe module.

  • 1-Channel 3.6 GHz or 2-Channel 1.8 GHz 12-bit A/D with DDC - XMC

    Model 71641 - Pentek, Inc.

    - Ideal radar and software radio interface solution- One-channel mode with 3.6 GHz, 12-bit A/D- Two-channel mode with 1.8 GHz, 12-bit A/Ds- Programmable one- or two- channel DDC (Digital Downconverter- 2 GB of DDR3 SDRAM- Sync bus for multimodule synchronization- PCI Express Gen. 2 interface x8 wide- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Clock up to four modules with Model 7194 High-Speed Clock Generator - PMC/XMC- Synchronize up to four modules with Model 7192 System Synchronization and Distribution Amplifier - PMC/XMC- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount

  • PXI Very High Density Versatile 2 Amp Multiplexer

    40-612A-002 - Pickering Interfaces Ltd.

    The 40-612A Very High Density Versatile Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves. Typical applications include signal routing in ATE and data acquisition systems. The 40-612 module uses high quality electro-mechanical relays, connections are made via a front panel 160 pin DIN41612 connector. The module can be software configured into one of a large number of different multiplexer modes. Relays allow the multiplexer banks to be set in 1 or 2 pole mode and inter-bank switching enables the channel count to be increased up to a maximum of 128

  • RF Amplifier

    SA1022 - Hangzhou Softel Optic Co., Ltd.

    *1000MHz Broadband RF signal amplifier, Line extender, RF amplifier GaAs MMIC used on the forward path, Power-Double module amplify module are used as output stage, Output level is stable and nonlinear index is good, import high index amplify module are used on return path, its distortion is little and SNR is high.*It is more convenient to debug because of plug-in (or adjustable) duplex filters, plug -in fixed (or adjustable) equalizers, plug-in output splitters and scientific and rational on-line detection ports.*The equipment can work steadily outdoor under bad environmental condition because of waterproof aluminum case, high reliability switching power supply and lightning protection system.

  • Isolation Amplifier

    Mornsun Guangzhou Science & Technology

    An isolation amplifier is an amplifier that provides isolation between the input and output of the circuits, including isolation between their associated power supplies. MORNSUN offers different types of analog isolation amplifiers, such as acquisition type signal conditioning modules, output isolation signal conditioning modules, two-wire loop power supply signal conditioning modules and signal isolators, etc. These analog isolation amplifiers feature excellent temperature drift characteristics of less than 50PPM/℃ across the entire operating temperature range of -40 ℃ to +85 ℃ and achieve isolation transmission, signal conversion (programmable for some models), HART communication, signal amplification, port protection and other functions. SIP, DIP, SMD and DIN Rail packages are optional.

  • Analog or Digital Communications Switching Systems with D Type Connectors

    RS Series - Cytec Corp.

    The RS Series computer controlled switching systems are designed to switch multi-wire groups of signal up to 25 wires. These systems are typically used for signals such as parallel TTL, RS232, RS422, WAN or modems, but can also be used for any group of analog or digital signals having a bandpass up to 30 MHz or a data rate up to 20 Mbps. A modular design concept is used that provides configuration flexibility by allowing display modules, different control modules and switch modules to be combined into a single chassis.LED displays and switch point status feedback are available on most systems. Computer control via IEEE488 (GPIB) and RS232 is standard, while TCP/IP Ethernet LAN, USB and manual controls are optionally available.

  • HEV & EV Power Tester

    EVd-40 - NuVant Systems, Inc.

    The EVd-40 Power Tester is a pre- and post-reconditioning tool for quality control of aftermarket HEV & EV battery production. The equipment integrates a “smart” charger (Sorensen XG 1700 or Kepco KLN 1500W) with NuVant Systems high power discharge electronics. The "power test" discharges battery packs at high power (10,000 watts), while tracking module voltages. The software monitors up to 40 module voltages at a time, identifying any weak modules. The "smart" charger performs charging constant current (CC), constant voltage (CV) and complex mixed mode constant current – constant voltage (CCCV) charging protocols at voltages up to 600 V. This enables recharge of any type of rechargeable battery.

  • PXI Very High Density Versatile Multiplexer

    40-612-002 - Pickering Interfaces Ltd.

    The 40-612 Very High Density Versatile Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves. Typical applications include signal routing in ATE and data acquisition systems. The 40-612 module uses high quality electro-mechanical relays, connections are made via a front panel 160 pin DIN41612 connector. The module can be software configured into one of a large number of different multiplexer modes. Relays allow the multiplexer banks to be set in 1 or 2 pole mode and inter-bank switching enables the channel count to be increased up to a maximum of 128

  • Solar Array Simulator

    LXinstruments GmbH

    Among other things, solar array simulators are required for testing satellite power supplies. An SAS (Solar Array Simulator), consisting of an interconnection of several Solar Array Simulator modules, maps the solar panels and displays the individual strings connected in parallel. Optionally, the individual SAS modules are monitored by a Second Level Protection, so that the test object is not damaged in case of errors with the voltage sources. Additional circuitry is implemented via project-specific test modules. The signal path to the DUT can be separated, e.g. for dynamic current measurements.The Keysight Solar Array Simulators used were specially developed for satellite applications and cover the significantly higher requirements regarding the control speed of MPP tracking compared to terrestrial applications.

  • Custom Industrial IoT Product Design

    PCTEL, Inc

    Our custom-designed access points, radio and sensor communication modules, and other Industrial IoT devices are purpose-built to deliver high performance, reliable connectivity under demanding conditions. We focus on applying the latest wireless technologies, including evolving cellular, WiFi, and Bluetooth/BLE standards, for specific applications across manufacturing, intelligent transportation, mining, utilities, oil and gas, and other industrial markets. Through the entire design and development cycle, from planning to production, our highly skilled RF and mechanical design teams deliver integrated solutions that are tailor-made for your specific needs and ready for deployment in the field.

  • Flashlight Solar Simulator

    Optosolar GmbH

    Flashlight Solar Simulators have the advantage of negligible temperature change to the solar cell. For this reason, they are primarily used in cell and module production environments. Also, they are a more budgetary alternative if large cell areas are to be illuminated, because it is easier to have excellent light uniformity on areas of 8 in x 8 in or larger. So, this type of solar simulator is also used for analysis of large area thin film solar cells. But care must be taken, as some materials (e.g. CIGS) have long inherent time constants, so that the pulse length (better: flash plateau) must be chosen accordingly.

  • Power Bead Inductors

    Pulse Electronics

    Power bead inductors are typically used in high current multi-phase voltage regulators that power processors, memory modules and high current ASICs and FPGA in a wide range of applications including servers, graphics cards, storage and data centers.   The construction consists of a ferrite core assembled over a 1T or 2T winding and which allows for extremely low DCR, high peak current and low AC losses.   Pulse has single phase, integrated phases and coupled inductor versions.  Our high volume manufacturing enables us to produce components that are cost-effective while maintain exceptional quality and reliability.

  • Radiometer

    CNR 4 - Kipp & Zonen B.V.

    The CNR 4 net radiometer consists of a pyranometer pair, one facing upward, the other facing downward, and a pyrgeometer pair in a similar con?guration. The pyranometer pair measures the short-wave radiation. And the pyrgeometer pair measures long-wave radiation. The upper long-wave detector of CNR 4 has a meniscus dome. This ensures that water droplets role off easily and improves the field of view to nearly 180, compared with a 150 for a flat window. All 4 sensors are integrated directly into the instrument body, instead of separate modules mounted onto the housing. But are each calibrated individually for optimal accuracy.

Get Help