Filter Results By:
Products
Applications
Manufacturers
-
product
CAPS NO2 Analyzer
AQMS-700
AQMS-700 CAPS NO2 analyzer is an atmospheric environment monitoring instrument based on the optical cavity attenuation phase shift technology (CAPS) which can directly measure the NO2 concentration in the ambient air and is widely used in the online monitoring of the NO2 content in the ambient air quality monitoring scene.
-
product
CAPS Trace-Level NO2 Analyzer
Model T500U
Teledyne Advanced Pollution Instrumentation
The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescense instruments. The CAPS measurement approach also reduces maintenance items, and removes the need for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expected maintenance interval of one year under typical ambient monitoring conditions.
-
product
Photolytic True NO2/NO/NOx Analyzer
Model T200P
Teledyne Advanced Pollution Instrumentation
The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.In the photolytic process the sample gas passes through a cell where it is exposed to light at a specific wavelength from an LED array. This causes the NO2 to be selectively converted to NO with negligible interference from other gases. Advances in the photolytic converter technology now yields NO2 conversion efficiency that is similar to molybdenum under typical ambient NO2 concentrations, but without the same interferences.
-
product
Gas Measuring Instruments
N Series
Teledyne Advanced Pollution Instrumentation
N Series Gas Measuring Units for SO2 (Sulfur Dioxide), NO, NO2, NOX (Nitrogen Oxide, Nitrogen Dioxide), CO (Carbon Monoxide), CO2 (Carbon Dioxide), O3 (Ozone), True, Direct NO2, NOX, NO, CH4 (Methane), THC (Total Hydrocarbons), and more
-
product
Mid-Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200M
Teledyne Advanced Pollution Instrumentation
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers.
-
product
CAPS True NO2-NOX-NO Analyzer
Model N500
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
product
Trace-level, Photolytic, True NO2/NO/NOx Analyzer
Model T200UP
Teledyne Advanced Pollution Instrumentation
The Model T200UP provides trace level measurements of NO and NO2 using our Model T200U NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.
-
product
High Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200H
Teledyne Advanced Pollution Instrumentation
The Model T200H combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. A high-efficiency stainless steel thermal NO2 converter provides durable and consistent operation under the harshest conditions (other converter options also available).The T200H may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.
-
product
Laser Spectroscopic Motor Exhaust Gas Analyzer
MEXA-ONE IRLAM
The MEXA-ONE IRLAM is an analyzer for the direct, simultaneous real-time measurement of the four relevant nitrogen-containing exhaust gas components NO, NO2, N2O and NH3.HORIBA's innovative infrared gas analysis technology, IRLAM™ (Infrared Laser Absorption Modulation), enables low-noise, high-precision measurement of four nitrogen compound gases (NO, NO2, N2O, NH3) in the low concentration range.
-
product
Chemiluminescence NOX-NO2-NO Analyzer
Model N200
Teledyne Advanced Pollution Instrumentation
The Model N200 uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases.
-
product
Chemiluminescence Method Ozone Analyzer
AQMS-350
The AQMS-350 is used to detect and evaluate the O3 concentration level of one of the environmental air quality parameters (SO2, NO2, CO, O3, PM2.5, and PM10) based on chemiluminescence technology. This analyzer can measure the concentration of O3 in ppb~ppm level, with strong anti-interference capability, high repeatability, and accuracy.
-
product
Mid-Range Chemiluminescence NOX-NO2-NO Analyzer
Model N200M
Teledyne Advanced Pollution Instrumentation
The Model N200M uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
product
High Range Chemiluminescence NOX-NO2-NO Analyzer
Model N200H
Teledyne Advanced Pollution Instrumentation
The Model N200H uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of high-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
product
Dynamic Dilution Calibrator
Model T700
Teledyne Advanced Pollution Instrumentation
The Model T700 is a microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations using up to 4 gas sources.The Model T700 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and to enable production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPTs. To ensure the highest accuracy of NO2 output, the T700 with the photometer option can measure the ozone concentration prior to performing a GPT. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the Model T700, covering time periods up to a year.
-
product
Trace-Level Dilution Calibrator
Model T700U
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
product
Sample Conditioner
PCA-400
Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.
-
product
Gas & Emissions Analyzer
Si-CA 8500
Accurate, reliable, robust & fast, the Si-CA 8500 Combustion Analyzer is the most powerful and advanced portable emissions analyzer on the market. Complete portable tool for emissions level monitoring of boilers, engines, and other combustion equipment, this emissions monitoring device can boast as many as 9 gas sensors, detecting one of the widest spectra of gases: O2, CO, NO, NO2, SO2, CO2, CxHy, High CO, VOCs and H2S.
-
product
Continuous Emissions Monitoring
atmosFIR CEM
atmosFIR CEM is a complete emissions monitoring system incorporating the atmosFIR 19” FTIR analyser. As completely hot and wet emissions measurement, atmosFIR CEM is ideal for complete measurement of multiple gases from applications such as incineration and power. A standard gas suite of NO, NO2, N2O, SO2, NH3, HCl, CH4, O2, CO2 and H2O is provided, but with the powerful FTIR analyser, further gases can be added easily in software.
-
product
Zero Air System
Model N701
Teledyne Advanced Pollution Instrumentation
The N701 is a fully self-contained source of clean, dry air for dilution calibrators. It can also simultaneously be used as a pressure source for activating instrument pneumatic valves and/or purge air for permeation tube ovens. The N701 includes a dewpoint sensor, an oil-less and diaphragm-free pump, and scrubbers to remove SO2, NO, NO2, O3, H2S, and NH3. An optional high performance heated converter is available for effective removal of Carbon Monoxide (CO) and Hydrocarbon gases.
-
product
High Range Chemiluminescence Oxides of Nitrogen Analyzer
Model T200H
The Model T200H combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. A high-efficiency stainless steel thermal NO2 converter provides durable and consistent operation under the harshest conditions (other converter options also available).The T200H may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200H comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
Mid-Range Chemiluminescence Oxides of Nitrogen Analyzer
Model T200M
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers. The T200M may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
Nitrogen Compounds Analyzers
TML produces a wide range of analyzers for the measurement of Nitrogen compounds, including those that measure 'True NO2'. All T Series analyzers offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our analyzers are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
product
Chemiluminescence NH3 Analyzer
Model T201
Teledyne Advanced Pollution Instrumentation
The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter (see "Features" tab for external converter photo) to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.
-
product
Sensor Solutions for IoT
Imec is a reference in the design of ultra-low power electronics, low-power algorithms to increase intelligence and data security, and in all aspects of data science. Our multi-sensor environmental monitoring platform features sensors for temperature, relative humidity, NO2, CO2, VOC (volatile organic compounds), particle matter, ambient light, sound, vibrations and presence detection. Our test platform is suitable for indoor and outdoor air quality monitoring and control, and can be used in smart buildings, smart cities and more.
-
product
Nitrogen Compound Instruments
Teledyne Advanced Pollution Instrumentation
Teledyne API produces a wide range of instruments for the measurement of Nitrogen compounds, including those that measure 'True NO2'. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring
-
product
On-board Emissions Measurement System
OBS-ONE GS Unit
OBS-ONE is the latest Portable Emissions Measurement System designed for engine/vehicle certification under real road conditions.It measures concentrations of emissions (CO, CO2, THC, NOx, NO2), particulate matter, air-to-fuel ratio, exhaust flow rate, GPS data, environmental conditions (atmospheric temperature, humidity and pressure) and calculates mass emissions.OBS-ONE features the highly adaptable, intelligent operating platform called “HORIBA ONE PLATFORM” which integrates other ONE series product data and optimizes test cell operation.
-
product
Air Quality Meters
An indoor air quality meter is used in confined spaces to prevent mold, to monitor CO2 levels, or to detect gas leaks. Whether portable or fixed, handheld or wall mounted, air quality monitoring equipment is essential for ensuring health and safety. At PCE Instruments, you will find air quality monitoring devices that meet various industry standards relating to personal safety and that are used to detect, measure and monitor relative humidity, ambient temperature and / or levels of carbon dioxide (CO2), volatile organic compounds (VOCs), formaldehyde (HCHO), freon and other refrigerants (CFC / HFC), phosphine (PH3), hydrogen sulphide (H2S), carbon monoxide (CO), nitrogen dioxide (NO2), oxygen (O2), ozone (O3) and other flammable, hazardous or toxic gases.
-
product
Zero Air System
Model T701
Teledyne Advanced Pollution Instrumentation
The T701 adds Modbus TCP/IP connectivity to the proven reliability and performance of our zero air systems. This allows remote monitoring of key instrument functions including dewpoint status, scrubber temperature, box temperature, and output pressure. Additionally, this digital access provides the ability to remotely disable the internal pump, allowing longer service intervals and less power consumption. The user can also remotely start instrument warm-up prior to arrival at the site.The T701 is a fully self-contained source of clean, dry air for dilution calibrators. It can also be used to create purge air for permeation tube ovens or burner air for FID analyzers. The T701 includes a dewpoint sensor, an oil and diaphragm-free pump, and scrubbers to remove SO2, NO, NO2, O3, H2S, and NH3. Optional high performance scrubbers are available to remove CO and Hydrocarbons.
-
product
Portable Gas Calibrator
Model T750
Teledyne Advanced Pollution Instrumentation
The Model T750 is a portable, microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750 is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.The Model T750 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPT. A number of calibration sequences may be programmed into the non-volatile memory of the Model T750, covering time periods up to a year.
-
product
High Performance Zero Air System
Model T701H
Teledyne Advanced Pollution Instrumentation
The T701H adds Modbus TCP/IP connectivity to the proven reliability and performance of our high purity zero air system. This allows remote monitoring of key instrument functions including dewpoint status, scrubber temperature, box temperature and output pressure. Additionally, this digital access provides the ability to remotely disable the internal pump, allowing longer service intervals and less power consumption. The user can also remotely start instrument warm-up prior to arrival at the site.The T701H is a fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with highly sensitive analyzers in ambient background and trace level applications. The T701H includes a dewpoint sensor, an oil and diaphragm-free pump, scrubbers to remove SO2, NO, NO2, O3, H2S and NH3, plus high performance scrubbers to remove CO and Hydrocarbons.