Filter Results By:

Products

Applications

Manufacturers

Noise

a signal's fluctuation other than that desired.

See Also: Pink Noise, White Noise, RF Noise, Distortion, NVH


Showing results: 1576 - 1590 of 2127 items found.

  • Force Balance

    Columbia Research Laboratories

    The force balance accelerometer has a classical critically-damped, second-order frequency response. There is no peaking in the response but simply a smooth roll-off above the natural frequency. This property along with the excellent characteristics of the "HP" torquer design makes Columbia accelerometers the best choice for demanding applications where precise DC and near-DC measurements are needed in demanding shock and wide band vibration environments. Columbia force balance accelerometers are available to cover virtually all applications. Low noise, high output units can be used for seismic structure motion studies while miniature, high range versions are optimum for measuring more violent high G environments encountered in many industrial, aircraft and missile applications.

  • Handheld Digital Spectrum Analyzer

    915M - Seeed Technology Inc.

    Frequency band: 910-920 MHz (enhanced to 900-930 MHz if an Expansion Module is connected)Frequency span: 112 KHz-10 MHz(enhanced to 30 MHz if an Expansion Module is connected)Graphics LCD 128x64 pixels, great visibility outdoorsPC Windows client supports Windows XP/Vista/Win7 both 32 and 64bitsBacklight for great indoor visibilityStandard SMA 50 ohms connector, a matching antenna is includedAmplitude resolution: 0.5dBmDynamic range: -115dBm to 0dBmAbsolute Max input power: +5dBmAverage noise level (typical): -110dBmRF Generator amplitude: 0dBm to 20dBmFrequency stability and accuracy (typical): +-10ppmAmplitude stability and accuracy (typical): +-3dBmFrequency resolution: 1KhzResolution bandwidth (RBW): automatic 2.6Khz to 80KhzWeight: 185gSize: 113x70x25 mm

  • Handheld RF Finders

    FC3000 Series - ACECO Electronics Corp.

    The latest advance in RF finder Frequency range: 10 MHz - 3 GHz Weight: 210g Case: 80 mm * 68 mm * 31 mm stamped aluminum with black anodized finish Battery: Internal 4 * AA 600 mAH NiCd pack 7 digit liquid Crystal Display with 1 KHz resolution Low power consumption (Average 6 hour battery life) Hold switch to lock display Digital filter prevents display of random noise Low battery indicator Ultra sensitive synchronous detector 16 section bargraph to show RF signal strength Automatically holds and tunes ICOM CI-V or AOR receivers Measure frequency and period

  • PCI Express Receiver Board

    AD12-2000-IRIGB - Ultraview Corporation

    The AD12-2000-IRIGB is a high performance wideband 0.3-1.8GHz PCIe-bus receiver on a single PCIe Gen3 board, that can continuously digitize a wide portion of the RF spectrum, with a 3.6GSPS 12-bit A/D that can be synchronized with stability of better than +/- 100 picoseconds with respect to an IRIG-B 1PPS signal and global time codes from a satellite receiver or local site time reference. Designed for demanding military, scientific, industrial, communications, safety and electrical power utility applications, the AD12-2000-IRIGB has 60dB of gain adjust range (manual and AGC with programmable loop bandwidth), a wideband noise figure of 9dB, +11dBm 1dB compression point, and 2dB peak-to-peak ripple over the 300MHz to 1.6GB frequency spectrum.

  • Saluki SE1022 DSP Lock-In Amplifier

    Saluki Technology Inc.

    SE1022 Digital Lock-in Amplifier provides an excellent performance within its bandwidth from 1 mHz to 102 kHz. With the advantage of the latest digital signal processing technology and high-precision 24-bit ADC, SE1022 can easily detect the phase and the magnitude of weak signals overwhelmed by various large noises. The performance of SE1022 is as good as other lock-in amplifiers brands, even better in some certain parameters, such as measurement accuracy, SNR, dynamic reserve. Otherwise, SE1022 integrates some special functions like multiple harmonic measurement and FFT, which meets the needs of scientific research and industrial application well.* Saluki SE1022 can be comparable to SRS SR830, even better and more stable.

  • Bench/System Precision Linear Regulated DC Power Supply With Digital Control, Single Or Triple Outputs, 105 To 242 Watts, With/without Remote Interfaces

    QL Series II - Aim-TTi

    Advanced dc power supplies, single or triple outputUp to 112 watts per outputVery high precision, very low noise, excellent dynamicsAdvanced user interface with numeric and rotary controlMultiple voltage/current ranges for increased flexibilityMultiple non-volatile memories for power supply set-upsSwitchable remote sense provides perfect load regulationComprehensive protection including OVP and OCP tripsCompact bench footprint; modular width for rack mountingAuxiliary output fully variable 1.00V to 6.00V at 3A with selectable voltage and current metering (T models)Bus programmable via USB, RS232, GPIB or LAN (P models)LAN interface is LXI compliantDuplicate power and sense terminals at rear (P models)

  • Monochromator Gratings - Type IV

    HORIBA, Ltd.

    HORIBA Scientific produces a wide range of holographic master gratings from which high precision replicas are manufactured.Using Type IV aberration-corrected monochromator gratings, a single concave grating disperses, collimates, and refocuses the light from the entrance slit onto the exit slit. Wavelength scanning is obtained through a simple rotation of the grating.The groove spacing of these gratings is computer-optimized to produce high quality images with a minimum of astigmatism and coma, even at large numerical apertures. Compared with Czerny-Turner monochromators (equipped with one plane grating, one collimating mirror and one focusing mirror), Type IV aberration-corrected monochromator gratings provide much better light collection efficiency and signal-to-noise ratio.

  • NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module

    785184-01 - NI

    ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.

  • NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module

    779357-01 - NI

    ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.

  • NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module

    780173-01 - NI

    ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.

  • 30W Power Supply, 8V, 3A or 20V, 1.5A

    E3640A - Keysight Technologies

    Output ratings (@ 0C to 40C)Range 1: 0 to 8 V / 3 ARange 2: 0 to 20 V / 1.5 AProgramming accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 10 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.2% + 10 mARipple & noise 20 Hz to 20 MHzNormal Mode Voltage: <5 mVpp / 0.5 mVrmsNormal Mode Current: <4 mArmsCommon Mode Current: <1.5 uArmsReadback accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 5 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.15% + 5 mA (<0.15% + 10 mA for output 2 of E3646/47/48/49A)

  • Acoustic Modem Option for Control Module

    Teledyne Marine Gavia ehf.

    ​Gavia AUVs can be fitted with the Teledyne Benthos ATM-900 Acoustic Modem. The ATM-900 Series Acoustic Telemetry Modem is the most advanced, multipath and noise tolerant, modem available. They are designed to meet both the high data rate requirements of commercial users, and the higher reliability, lower data rate requirements of the military. The modems employ two modulation techniques: phase shift keying (PSK), which provides the highest bit rate, and multiple frequency shift keying (MFSK), which provides reliability in a multipath environment, or when the modems are required to operate in a low signal-to-noise (SNR) environment. The ATM-910 Series can transmit data using PSK modulation for reception by a Gavia Modem Deckbox, but receives data using MFSK modulation only. MFSK modulation is a spread spectrum modulation process that transmits multiple tones simultaneously.

  • Measurement System for ESD Protection

    SampleProtect - Oxford Instruments plc

    The SampleProtect measurement system is ready to go, and comes complete with Oxford Instruments’ Cryofree bottom loading cryostat – the OptistatDry BLV, Zurich Instruments’ MFLI Lock-in Amplifier, a specially designed ESD break-out box and high quality measurement grade cables. The patent-pending puck style mounting from Oxford Instruments provides safe installation of your samples. The MFLI 500 kHz Lock-in Amplifier (capable of 500 kHz demodulation as standard) with MF-MD multi-demodulator capability brings the benefits of high performance signal processing at low and medium frequencies. The differential voltage and current inputs of the MFLI are optimised for low noise operation and the high oversampling rate ensures an even better signal to noise ratio. Zurich Instruments’ unique LabOne® control software provides a toolset including an integrated oscilloscope, a spectrum analyser, a plotter and a parameter sweeper.

  • Bench PIM Tester - iBA series

    iBA - Kaelus

    Passive Intermodulation (PIM) occurs when multiple RF signals encounter defects in materials or workmanship in an RF path. These defects behave like a mixer causing noise to be generated at mathematical combinations of the original carrier frequencies. PIM interference that falls in the receive band of a wireless system elevates the noise floor resulting in high dropped call rates, call blocking, slow data transmission speeds and decreased system capacity.Kaelus is the industry leader in Passive Intermodulation test solutions. Since 1996 Kaelus has supplied RF equipment manufacturers around the world with precision IEC compliant test equipment to perform this critical test. From initial product design through high-volume manufacturing, Kaelus offers a wide range of PIM test solutions that enable equipment manufacturers to quickly and confidently verify the performance of their products.

  • High-Density Precision SMU (10 PA, 30 V)

    PZ2131A - Keysight Technologies

    The Keysight PZ2131A is a high-channel density precision source / measure unit (SMU) having 5 channels per module and saving space for a wide range of applications requiring numerous precision power supplies. The narrow-pulse function and fast Digitizer Mode allow the PZ2131A to expand the conventional static DC measurements to emerging dynamic measurements. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2131A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2131A suitable for noise-sensitive applications such as quantum computing as well.

Get Help