Filter Results By:

Products

Applications

Manufacturers

Noise

a signal's fluctuation other than that desired.

See Also: Pink Noise, White Noise, RF Noise, Distortion, NVH


Showing results: 1636 - 1650 of 2127 items found.

  • NI-9262, 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module

    785503-01 - NI

    1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module - The NI-9262 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. The NI-9262 module includes a channel-to-earth ground isolation barrier for safety and noise immunity.

  • NI-9262, 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module

    785503-02 - NI

    1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module - The NI-9262 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. The NI-9262 module includes a channel-to-earth ground isolation barrier for safety and noise immunity.

  • C Series Voltage Output Module

    NI

    The C Series Voltage Output Module helps you update analog output models that feature overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. This module includes up to 16 channels. Some models include a channel-to-earth ground double isolation barrier for safety and noise immunity as well as improved signal quality, and some higher density models conserve chassis space, which leaves room for other measurement types.The C Series Voltage Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Mobile Sound Ranging Array

    MSRA - Microflown AVISA B.V.

    In a peer to peer conflict, weapon location radars used for counter battery purposes will be extremely vulnerable.With aerial/satellite based surveillance available for the opponent, radars will be seen. With electronic warfare means being omnipresent, radars will be triangulated and jammed. There is an urgent need for 24/7 persistent surveillance with (preferably) passive sensors. With mobility being the key for survival on the battlefield, rapid re-deployable, or even truly mobile sensor capabilities are required. Therefore, the traditional sheer sound pressure based sound ranging capability becomes obsolete, as the triangular footprint of the sensor nodes is too large to be installed on a manned, or unmanned platform. With the trend towards longer ranges and “shoot and scoot” drills, the concept of capturing the muzzle blast noise becomes questionable, as the speed of sound is too slow to provide timely localizations.

  • Trace-Level UV Fluorescence SO2 Analyzer

    Model T100U - Teledyne Advanced Pollution Instrumentation

    The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.

  • 0.1Hz-3.7GHz Frequency Counter

    FC-3000 - MCH Instruments Co.,Ltd.

    Features:*Frequency measuring range: 0.1Hz to 100MHz in A input, 80 MHz to 3.0GHz in C input.*Period,Total and RPM measurement for input A*9 Digit display with 0.01mHz resolution in 1 Sec (By Ext.Reference signal).*RS-232C serial interface function for communication with computer.*High sensitivity Extemal reference input function(>=1.5Vrms).*Peciprocal technique for high resolution at low counting frequencies .*Self check function executed to perform a automatic self diagnosis of various counter function.*Push-scanning for selecting Function and Gate time.*Low-pass filter(100KHz,-3dB)installed for removing noise signsl in low frequency measuring.*AC/DC coupling function(Selectable AC/CD Coupling)*10:1 Input Attenuation(Selectable×1/×10 Attenuator)*Data hold function

  • 47~2400MHz FTTH CATV & SAT-TV Optical Receiver

    HRS-24-H1 - Hangzhou Huatai Optic Tech. Co., Ltd.

    Huatai HRS-24-H1 product series is a kind of CATV & SAT-IF optical receiver with high-performance and high-index. 7~2400MHz operate bandwidth. Output level Vo=86dBμV ( Pin=-2dBm ), suitable for FTTH, FTTP fiber access network. It is a low power consumption, high performance and excellent cost performance CATV & DBS network ONU(Optical network unit). This series product adopts high sensitivity receiving tube and special low noise matching circuit. Under 3.8% modulation, when transmitting in full channels and with receiving power of –8dBm, the CNR can still reach high index of 48dB and low inter modulation index. If adopting HRS-24-H1, it is only need very low optical power to reach 48dB CNR required by the user.

  • 8-Channel, 10 MHz Precision ReferenceWith Sine and Logic Outputs

    ITS-6200 - Innovative Technical Systems

    The ITS-6200 is a versatile 10 MHz laboratory frequency reference useful for synchronizing test instruments to a common standard. Eight outputs are provided, each which can be configured independently as sinewave or logic level square-wave signals. Additionally, CMOS logic levels can be set for 5V, 3.3V, or 2.5V logic family compatibility. A 10 MHz reference input is provided to phase lock the ITS-6200 to an external reference, such as a GPS or Rubidium standard, or cascade multiple ITS-6200 units for additional outputs. The low phase noise and high stability OCXO within the ITS-6200 is suitable for the most demanding applications, whether free-running or phase locked. The compact size and low power consumption makes the instrument highly portable and suitable for AC-powered operation in the lab or battery operation in mobile or field applications.

  • Bench Power Supply, Single, Adjustable, 1 Output, 1 V, 60 V, 250 mA, 1.6 A

    72-8340A - Tenma

    The 72-8340A is a 100W switching mode laboratory grade Power Supply with current limiting control, is designed with the objectives of high accuracy, compactness and easy portability. 4 digit display LCD of voltage and current for high precision. The slim tower housing makes it ideal for tight work bench. It is light and conveniently portable with a collapsible handle. The large and illuminated LCD display provides clear and sharp readings even under dim light. The output power on off switch allows safe and handy operations. The tracking OVP (output over voltage protection) ensures a better and tighter protection to voltage sensitive loads. It has good line and load regulations, high efficiency, low ripple and noise that are typical of advanced switching mode power supply.

  • 100W Dual Output Power Supply Two 35V, 1.4A or 60V, 0.8A

    E3649A - Keysight Technologies

    Output ratings (@ 0C to 40C) 2 outputs Range 1: 0 to 35 V / 1.4 ARange 2: 60 V / 0.8 A Programming accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 10 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.2% + 10 mARipple & noise 20 Hz to 20 MHz Normal Mode Voltage: <8 mVpp / 1 mVrms Normal Mode Current: <4 mArms Common Mode Current: <1.5 uArms Readback accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 5 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.15% + 5 mA (<0.15% + 10 mA for output 2 of E3646/47/48/49A)

  • PXIe-4309 , 28-Bit, 32-Channel, 2 MS/s, ±15 V Flexible Resolution PXI Analog Input Module

    784471-01 - NI

    28-Bit, 32-Channel, 2 MS/s, ±15 V Flexible Resolution PXI Analog Input Module—The PXIe-4309 samples up to 32 differential channels and multiplexes the analog input channels across eight simultaneously sampling ADCs. The module samples eight input channels up to 2 MS/s/ch (single channel per ADC), and 32 input channels up to 100 kS/s/ch (four channels per ADC). The module's flexible resolution ranges from 18 bits at 2 MS/s/ch to 28 bits at 2 S/s/ch. The module features on-board signal averaging and filtering, auto-zero measurement switching, and a chopping mode that uses a pair of channels to provide high levels of noise rejection and to enable accurate and repeatable nano-volt measurements.

  • Power modules

    G.R.A.S. Sound & Vibration A/S

    It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation

  • Microwave System Amplifier, 2 GHz to 26.5 GHZ

    83018A - Keysight Technologies

    The Keysight 83018A microwave system amplifier is a compact, off-the-shelf amplifier designed for systems designers and integrators. This amplifier provides power where you need it to recover system losses and to boost available power in RF and microwave ATE systems. The ultrabroad bandwidth from 2 to 26.5 GHz allows the designer to replace several narrow bandwidth amplifiers with a single Keysight amplifier, eliminating the need for crossover networks or multiple bias supplies. The standard Keysight 83018A includes internal directional detectors for external leveling applications. With excellent noise figure relative to its broad bandwidth and high gain, this amplifier significantly improves system noise figure and dynamic range. The Keysight 83018A comes equipped with a low profile heat sink, an integral mounting bracket, and a two-meter dc power supply cable. Thermal characteristics and power supply design allow fast, easy integration into most measurement systems.

  • RF Synthesizers Modules

    Holzworth Instrumentation, Inc.

    Holzworth's RF Synthesizers Modules were originally designed as the internal, tunable LO test sources for Holzworth phase noise analyzer products. Due to the need for easy integration, the HSM Series designs incorporate a long list of electrical and mechanical features to satisfy the demanding requirements of today's high performance communications systems and integrated test systems. FIELD PROVEN RELIABLITY with MTBFs exceeding 240kHrs.

  • Data Acquisition Systems

    LMS SCADAS - Siemens Digital Industries Software

    The LMS SCADAS state-of-the-art data acquisition systems cover all types of noise, vibration, durability testing and engineering tasks in the lab, in the field, with a PC or through autonomous recording. Seamless integration with LMS Test.Lab and LMS Test.Xpress provides you with reliable results and optimal testing productivity. Take your mind off the deadline and focus on the test. From lab to mobile to portable.

Get Help