Showing results: 1111 - 1125 of 2086 items found.
-
Analog Devices Inc.
Analog Devices offers RF Front-End ICs for phased array antenna solutions. These RF Front-End ICsare placed right at the antenna element and can quickly switch between transmit and receive functions in radar applications. The power amplifier on the transmit side is highly efficient operating in short pulse durations. The low noise amplifier on the receive side has a low noise figure with high linearity so that it won’t distort the incoming return signal. The RF Front-End IC also incorporates a high performance switch to toggle between the transmit and receive paths. Highly integrated planar phased array antennae need small form factor solutions, and Analog Devices has integrated the switch, low noise amplifier, and power amplifier into a small surface mount package as well as the decoupling capacitors, providing an optimal solution.
-
SL100 -
TEAM SOLUTIONS, INC.
The SL100 uses a standard 16450 UART with baud rate settings that makes it capable of communicating with a Chrysler CCD Vehicle bus. The SL100 uses a protected interface driver chip, as prescribed by the bus specification, to connect with vehicle peripherals in a robust and highly noise immune way. The card automatically configures to become another COM port by using the built-in O.S. drivers that are tried and tested and are optimized to work in the Windows environment.
-
GreenPoint® -
ON Semiconductor
The GreenPoint Design Simulation Tool is an interactive online design and verification tool to help you generate and validate an electronic design. The simulation module provides an interactive design and verification environment. The power analysis module provides an interactive environment to analyze the performance of intelligent power modules (IPMs). The Phase Noise Explorer module enables an interactive environment for advanced phase noise/jitter analysis of clock tree designs.
-
Metra Mess- und Frequenztechnik in Radebeul e.K.
The piezoelectric accelerometers on this page are intended for the measurement of lowest vibrations. Typical fields of application include the monitoring of buildings, dams, bridges, oil platforms and pipelines. These sensors are often called seismic accelerometers because they are used to monitor construction activity, volcanoes and earthquakes. Their high sensitivity is achieved -unlike other high sensitivity accelerometers- by the sensing element itself and not by internal amplification. From this results highest resolution and lowest noise.
-
130A23 -
PCB Piezotronics, Inc.
Nominal Microphone Diameter: 1/4" Frequency Response Characteristic (at 0 incidence)Free-FieldInherent Noise (A Weighted)<30 dB(A) re 20 Pa<30 dB(A) re 20 Pa Dynamic Range (High)150Environmental Temperature Range ( Temperature Effect on Output (-10 to +50 C)<0.7 dB<0.7 dB[2] Influence of Axial Vibration Excitation Voltage 18 to 30 VDC18 to 30 VDC
-
2575 -
PCB Piezotronics, Inc.
Performance:Nominal Microphone Diameter1"1" Frequency Response: Characteristic (at 0 incidence) Random IncidenceRandom Incidence Open Circuit Sensitivity: 45 mV/Pa Resonant Frequency (90 Phase Shift)8000 Hz8000 Hz[1] Inherent Noise<10 dB(A) re 20 Pa<10 dBTemperature Range (Operating)TBD FTBD C Humidity Coefficient of Sensitivity (0 to 95%, non-condensing)0.001 dB/%RH
-
Silent Solutions LLC
SILENT Troubleshooting and Retrofit Service provides rapid problem resolution. We will work onsite at your facility, or if you prefer, you may ship the product to our troubleshooting lab for an immediate problem review. After seeing their design staff bogged down for weeks, our clients are delighted to see us bring a noise problem under control in a matter of days, and with practical design solutions that are manufacturable.
-
HSX SERIES -
Holzworth Instrumentation, Inc.
The HSX Series are broadband frequency sources exhibit industry leading phase noise and spectral purity performance coupled with a highly accurate dynamic range of up to +20dBm and down to -110dBm. The 1U high form factor offers 1, 2, 3 or 4 channel models; all providing the ultimate in frequency accuracy, while the phase coherent RF outputs provide the ultimate in channel-to-channel stability.
-
Integris 3000 -
Absolute Analysis
Most modern cell tower network configurations place the Remote Radio Head (RRH) at the top of the tower and the baseband unit(BBU) at the bottom of the tower. While this configuration is advantageous for both computational efficiency and mitigation of RF loss across the cable, it means the only place along RF can be accessed is at the top of the tower. This forces field technicians to have to climb the tower to measure and debug RF noise problems.
-
MGC-1 -
Macintyre Electronic Design Associa
The MGC-1 is a low noise high sensitivity single axis AC magnetic field sensor used for the measurement of audio frequency fields. Because of its innovative design, the MGC-1 amplitude response is insensitive to the frequency of the field over its 5 Hz to 10 kHz frequency band. Accuracy at 1 kHz is ±1%, and the amplitude response stays within 2 dB peak-to-peak over the bandwidth.
-
MGC-1A -
Macintyre Electronic Design Associa
The MGC-1A is a low noise high sensitivity single axis AC magnetic field sensor used for the measurement of audio frequency fields. Because of its innovative design, the MGC-1A amplitude response is insensitive to the frequency of the field over its 30 Hz to 10 kHz frequency band. Accuracy at 1 kHz is ±1%, and the amplitude response stays within 2 dB peak-to-peak over the bandwidth.
-
CMOS Global Shutter -
Framos Technologies d.o.o.
Its outstanding performance, success, and large consumer capacity were among some of the triggers resulting in Sony’s decision to shut down their CCD sensor development and production, despite their technology and market leadership. The Pregius technology series combines the image quality from its technology with high readout speeds, an electronic global shutter and the low noise EXview HAD II Technology from the CCD designs.
-
897 -
Simpson Electric Company
Designed for conducting personal noise surveys, the 897 Dosimeter is versatile enough for the experienced hygienist but simple enough for the novice technician. The data storage feature allows you to view reports on the computer or print them for use later during inspections. Purchase the 897 by itself or in the SMS-2 kit with all of the relevant accessories, including calibrator, nose cone, microphone clip, wind screen, and serial and parallel printer cables.
-
OS-CON™ -
Panasonic Industrial Devices Sales Company of America
Panasonic's OS-CON™ Aluminum-Polymer Solid Capacitors are available in both surface-mount and through hole types. These Solid Electrolyte Aluminum OS-CON™ Capacitors utilize aluminum and a highly conductive polymer material to offer low ESR, excellent noise reduction and ripple current capabilities. The OS-CON Series parts are characterized by a long-life and minimal ESR changes throughout the entire product line’s rated temperature range.
-
Eckel Noise Control Technologies
Eckel offers a wide range of standard rooms and custom-made suites to meet audiological clinical and research requirements. All combine high performance, versatile design and economy. Eckel acoustically engineered G-Panel construction affords excellent noise reduction. Choose from 19 demountable (G-Series panels) standard models and custom-made rooms for your specific needs. Rooms are easy to install, easy to take down and move.