Filter Results By:

Products

Applications

Manufacturers

OTA

signals transmitted without cables. AKA: Over The Air

See Also: Wireless, Over the Air, Antenna Measurement


Showing results: 61 - 75 of 94 items found.

  • Radar Altimeter Test Set

    Core Technology - Eastern-Optx

    Eastern OptX core technology enables the conversion of microwave signals to optical signals (E/O), time delaying this signal then reconverting the light back to original microwave signal (O/E) with superior fidelity over traditional time delay methods. Products include Radar Target Simulation, Radar Altimeter Testing, Channel Simulation (Air Interface) and Multipath Creation.

  • Condensate Pumps

    Sauermann Group

    Sauermann has been manufacturing condensate removal pumps for over 40 years. Our pumps are designed to detect and remove condensates from heating, ventilation, air conditioning and refrigeration (HVACR) systems.

  • Desktop Indoor Air Quality CO2

    Extech CO210 - Extech Instruments Corporation

    CO210 is a Desktop Indoor Air Quality CO2 Monitor/Datalogger. Measurement ranges are 0 to 9,999 ppm (CO2), 14 to 140°F (-10 to 60°C) for Air Temperature and 0.1 to 99.9% for Relative Humidity. It features Minimum/Maximum CO2 value recall, Year/Month/Date/Time display, and an Automatic Baseline Calibration (minimum CO2 level over 7.5 days) or manual calibration in fresh air. Comes with AC adapter and user manual.

  • UAV / Robotics

    Antenna Research Associates

    The telemetry antennas help ground engineers and control room personnel acquire airborne and ground telemetry data. With over 55 years of antenna design and manufacturing experience, the suite of telemetry antennas developed by ARA can operate across a wide range of frequencies and environmental conditions. The wide range of bandwidth, sizes, and mounting options make these antennas suitable for air platforms and ground stations. These antenna designs function efficiently to monitor system telemetry over long distances for drones and Unmanned Aerial Vehicle (UAV) systems.

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-400 - REXMED Industries Co., Ltd.

    MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-280 - REXMED Industries Co., Ltd.

    MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Wireless Devices

    Schweitzer Engineering Laboratories, Inc.

    Wireless devices use radio signals to communicate and pass data over the air, eliminating the need for traditional cabling.

  • RF & Microwave Passive Components

    SHF Communication Technologies AG

    SHF’s microwave components are broadband devices suitable up to 110 GHz. Our SHF BIAS TEES are well known but perhaps a slight variation does suit your application even better. DIPLEXERS are bias tees with a certain bandwidth in the low frequency path to combine or separate high frequency and low frequency signals into or out of a single line. DC-FEEDERS are bias tees without the capacitor. Therefore, it provides slightly lower insertion loss in case it is connected to an AC-coupled device which already has a capacitor on its input. Based on our air line construction, these passive components provide resonance-free transmission over the entire operating range.

  • Dual Vapor Gravimetric Sorption Analyzer

    DVS Resolution - Surface Measurement Systems

    DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.

  • Thermal Division Overview

    MPI Thermal Test Systems

    MPI Thermal is a division of MPI Corporation. With over 60 years of combined thermal control system experience with our international engineering teams, this has brought about a comprehensive product portfolio of thermal air stream systems for today's manufacturer's environmental test chamber needs.

  • Portable Analyzers

    Alpha Moisture Systems

    The key to the operation of Alpha Moisture Systems' Portable Analysers is the unique Desiccant Dry-Down Chamber. By keeping the sensor dry between tests, the special assembly of the head ensures that the instrument is always ready for immediate use. The head assembly consists of two chambers which have a telescopic action. When the head assembly is in the 'closed' or 'Dry-Down' position, the sensor is completely surrounded by desiccant, which absorbs the remaining water moisture from the sensor and hence it is dry and ready for use. The small space at the bottom of the test chamber enables the sample pipe to be purged before the test commences without wetting the sensor. By placing a finger over the outlet of the head, the sample pressure is able to open the test chamber automatically, exposing the sensor to the gas being tested and enabling accurate reading of moisture content in the sample gas. After each test the head assembly is closed by depressing the inner section so that the sensor will again be dried by the desiccant, leaving the sensor ready for use time and time again. The desiccant is kept in the inner chamber and is not exposed to ambient room air or the sample gas, therefore there is no need for frequent regeneration or replacement of the desiccant.

Get Help