Showing results: 1981 - 1995 of 3048 items found.
-
C3121P-2 -
COMET SYSTEM, s.r.o.
Thermometer, hygrometer is designed for direct measurement of temperature, relative humidity for compressed air up to 25 bars with 2 meters cable. Audio and optical alarm of measured values. Memory of minimum and maximum measured values. Function Hold - manual storing of actual values for later displaying.
-
C3121P-4 -
COMET SYSTEM, s.r.o.
Thermometer, hygrometer is designed for direct measurement of temperature, relative humidity for compressed air up to 25 bars with 4 meters cable. Audio and optical alarm of measured values. Memory of minimum and maximum measured values. Function Hold - manual storing of actual values for later displaying.
-
10775A -
Keysight Technologies
The Keysight 10775A combines a straightness interferometer and reflector to provide measurements over a range of 1 to 30 meters (3 ft to 100 ft). The optics form a highly-accurate optical straightedge that can measure the straightness of travel of machine-tool and measuring-machine coordinate motions with a resolution of 0.1 micrometer (10 microinch).
-
AE600 -
Deviser Instruments
The AE600 CWDM Channel Analyzer is a handheld tester which measures transmitting optical power on CWDM system. Compared with the AE500, this analyzer is able to simultaneously verify 16 CWDM channels between the wavelengths of 1270 nm and 1610 nm. The measurements can be displayed in both graphical or list formats.
-
39E12WUX98Y2VCM0-SOSA1 -
ELMA Electronic, Inc.
3U OpenVPX development platform aligned with SOSA 1.0. It supports both SOSA and CMOSS profiles. It includes: 2 I/O intensive SBC, 7 primary payload, 1 radial clock, 2 switch and 2 power. Includes VITA 67.3 RF and optical I/O modules.
-
APL – OP01 -
Arden Photonics LTD
The APL-OP01 OCT phantom is a device to qualitatively and quantitatively characterize the performance of an Optical Coherence Tomography (OCT) system, including spatially varying resolution, sensitivity, distortion and scan linearity. The phantom contains four geometrical patterns inscribed within a substrate to form localized refractive index changes.
-
Linkham Scientific Instruments
Specialists in temperature controlled microscopy, Linkam Scientific Instruments, announce the launch of their Optical DSC450 which enables simultaneous visualization of thermal processes for improved materials characterisation. The Optical DSC450 enables the user to measure glass transitions and melting behaviour of a wide range of substances whilst accurately controlling temperature from -196 °C to 450 °C. The atmosphere of the stage can also be purged with gas as required by the user. A new feature which will increase the characterisation capabilities of the DSC system is to combine it with imaging capability. The new LINK Digital Imaging module enables additional information to be obtained by correlating optical changes such as colour with temperature. The new TASC analysis tool takes this further. TASC (Thermal Analysis by Surface Characterisation) is a new image analysis capability which enables structural changes in samples to be tracked and quantified optically. It has the unique ability to measure local transition temperatures allowing different points on a sample to be identified. The new DSC system is great tool to use in research and quality control to measure quantitative values for glass transitions, melting peaks and sample purity and, when combined with TASC, even sample homogeneity.
-
DF-TV7 -
Teledyne Gas & Flame Detection
The device offers a wide range of output options, as standard and is suitable for use in SIL 2 applications. The detector can be configured to communicate with a wide range of fire panels, controllers, and PLCs and offer HART 7 and Syntel (Lonworks) protocols for addressable event monitoring. The devices come standard with a configurable 4-20mA or 0-22mA (PLC) output, two configurable alarm relays, and two detector status LEDs.All MultiFlame detectors are equipped with a continuous optical lens auto-check to ensure that the optical path is clear and that the detector functions properly. Sensors can be replaced easily in the field without removing any cable glands. Devices are easy to test and configure using a TLU600 wireless hand-held unit that is approved for use in hazardous areas. The TLU600 can also be used for wireless testing of the optical and output circuits. The TLU600 can also be used for wireless testing of the optical and output circuits.
-
11PMK-W5 -
Standa
11PMK-W5 power detectors surface absorber stands up to average power densities of 100 kW/cm². That is the best in the world for average power density. 11PMK-W5 high-power detectors come ready to mount on a rod, a bracket and the square case even lets you set them right on the optical table.
-
FiberLabs Inc.
Module type ASE light sources are small in size and easy to integrate into equipments. The dimensions are different between models, and five sizes are available from the smallest MSA to S, M, M2 and L. All of them are operated on 5 VDC and the optical properties are the same as the corresponding bench-top models.
-
BOD 24K Family -
Balluff GmbH
High resolution and precise measurement at close range. Optical distance sensors in the BOD 24K product family combine precision and intelligence. You can use this family‘s high resolution and accuracy to solve difficult problems with ease. For example, fine positioning of robot arms or quality inspection of small components.
-
Appointech, Inc.
The fiber-optic coaxial PIN-TIA receiver module is designed for SONET/SDH fiber-optical communicationnetworks, using reliable InGaAs PIN photodiode (PD) highly integrated with low noise transimpedence amplifier(TIA) to convert a long wavelength input optical signal into a differential (or single) output. It is a highly reliablemodule with excellent performance.
-
Monarch Instrument
Smart Laser Sensor is an internal battery-powered optical sensor utilizing a visible Class 3R Laser for a TTL pulse output. Operating range up to 65 feet with reflective tape and up to 3 feet* (1 m) off contrasting color targets, key-ways, bolt heads or blades.
-
C4141-4 -
COMET SYSTEM, s.r.o.
Audio and optical alarm of measured temperature. Minimum/maximum memory. memory of minimum and maximum temperature included traceable calibration certificate. LCD backlight.With external air temperature-humidity probe on a 4 meters cable. Probe diameter is 18mm, length 135mm. Built-in indoor temperature and air pressure sensors.
-
Part No. 601 -
Teledyne Defense Electronics Relays & Coax Switch
The 601 is a state-of-the-art solid-state relay designed for use in AC power switching applications. These relays utilize optical isolation and feature zero-cross switching. MSL 1Available options include:601-1 5A, 280Vac Load; 3.0-32Vdc Control601-2 10A, 280Vac Load; 3.0-32Vdc Control