Showing results: 706 - 720 of 1065 items found.
-
HS6-DIFF-200XMS-W5 -
TEAM SOLUTIONS, INC.
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
HS6-DIFF-1000XMG-W5 -
TEAM SOLUTIONS, INC.
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
HS6-DIFF-200XMG-W5 -
TEAM SOLUTIONS, INC.
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
HS6-DIFF-1000XMEG-W5 -
TEAM SOLUTIONS, INC.
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
HS6-DIFF-1000XMSG-W5 -
TEAM SOLUTIONS, INC.
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
HS6-DIFF-1000XMEGS-W -
TEAM SOLUTIONS, INC.
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEGS EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
782058-01 -
NI
PXIe, 5 GHz, 12.5 GS/s, 8-Bit PXI Oscilloscope—The PXIe‑5186 high-speed PXI oscilloscope has two channels with flexible settings for coupling, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require up to 5 GHz of analog bandwidth and flexible measurement configurations. The PXIe‑5186 also features PXI synchronization and data streaming capabilities.
-
Series Oscilloscopes -
Keysight Technologies
Provide clock recovery capabilities for optical and electrical NRZ and PAM-4 signals up to 64 GBaud with jitter spectrum analysis (JSA) and integrated variable equalizers advanced features
-
PRB-HP-3250i -
TEAM SOLUTIONS, INC.
Oscilloscope Probe 1:1-1:10 - HP-3250i250 MHz bandwidth, rated 600 V.The Oscilloscope Probe 1:1-1:10 - HP-3250i is a 1:1-1:10 selectable passive high impedance oscilloscope probe with 250 MHz bandwidth (1:10) designed and calibrated for use on oscilloscopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with an oscilloscope having an input capacitance of 10 to 30 pF.
-
N7020A -
Keysight Technologies
The N7020A power rail probe can be used with the Keysight InfiniiVision 3000T and 4000 X-Series oscilloscopes, InfiniiVision 6000 X-Series oscilloscopes ordered after Feb 1, 2016, the Infiniium S-Series DSO and MSO high-definition oscilloscope, and the Infiniium 9000 Series DSO and MSO oscilloscopes running software revision 5.20 or newer. If you need higher bandwidth, the N7024A power rail probe has a bandwidth of 6 GHz and can be used with S, V, and Z-Series Infiniium oscilloscopes.
-
ZD200 -
Teledyne LeCroy
With the ProBus interface, the ZD200 becomes an integral part of the oscilloscope. The probe sensitivity and offset are automatically optimized based on the oscilloscope gain settings, so control is transparent to the user. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
AP033 -
Teledyne LeCroy
Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
U1580A -
Keysight Technologies
The Keysight U1580A test leads are compatible with the U1600A Series handheld digital oscilloscope probes and test leads. These test leads are used for the DMM terminal on the oscilloscopes.
-
-
PulseGen -
land-boards
Pulse Generator for use with an oscilloscope as a Time Domain Reflectometer (TDR).