Filter Results By:

Products

Applications

Manufacturers

Oscilloscopes

Analyze waveforms of electronic signals by producing a trace on a display screen of corrosponding oscillations of voltage and current.

See Also: Scopes, Fiberscopes, Microscopes, Borescopes, Endoscopes, Stethoscopes, Stroboscopes, Synchroscopes, Telescopes, Vectorscopes, Analog Oscilloscopes, Digital Storage Oscilloscopes, Oscilloscope Probes, Waveform, Digitizers


Showing results: 961 - 975 of 1065 items found.

  • PXI Quad 4 to 1 Mux 1GHz 75 Ohm SMB

    40-749-751 - Pickering Interfaces Ltd.

    The 40-749 is a quad 4 to 1 RF MUX available in 50 Ohm or 75 Ohm versions occupying a single PXI slot. The module is available with SMB or SMA connectors for 50 Ohm versions or, 1.0/2.3 or Mini SMB connectors for 75 Ohm versions. Applications for the 40-749 include routing high frequency signals to and from oscilloscopes, analyzers, signal generators and synthesizers, telecoms tributary switching, video/audio switching and switching high frequency logic signals.

  • PXI Quad 4 to 1 Mux 1.3GHz 50Ohm SMB

    40-749-511 - Pickering Interfaces Ltd.

    The 40-749 is a quad 4 to 1 RF MUX available in 50 Ohm or 75 Ohm versions occupying a single PXI slot. The module is available with SMB or SMA connectors for 50 Ohm versions or, 1.0/2.3 or Mini SMB connectors for 75 Ohm versions. Applications for the 40-749 include routing high frequency signals to and from oscilloscopes, analyzers, signal generators and synthesizers, telecoms tributary switching, video/audio switching and switching high frequency logic signals.

  • O-E PROBE

    OptCom Company, Ltd

    O-E probe is the unit to convert optical signals to electrical signals. It can be connected to Oscilloscopes or data loggers via a BNC connector and monitor the conversion waveform. It can acquire the optical signal easily by just pointing the optical fiber probe at the light source. Recently, more and more light sources utilize optical modulation for next generation lighting such as LED. Acquiring the emission timing is required to measure the emission phenomenon of the light source. This O-E probe unit is the ideal tool for these tasks.

  • HV Voltage Dividers

    ROSS ENGINEERING CORPORATION

    *DC up to 10MHz*1kV to 1,200kV DC or PK AC*To 1,875kV Impulse*To ±0.01% DC Accuracy Accredited*To ±0.2% AC Accuracy (50/60Hz) Accredited*To ±3% DC-1MHz Wideband*±3dB 5 to 30 MHz*Compact & Lightweight*For Oscilloscopes*For Recorder*For Digital Multimeters*Very Partial Discharge/Low Corona*Very Low Phase Shift*Resistive*Capacitance*Compensated Wideband*Indoor & Outdoor*Electronic and Power Class*Match Wideband Differential*High Voltage Power Quality Instrumentation

  • 4.0 GHz, 0.6 pF, 1 MOhm Active Voltage Probe

    ZS4000 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.6 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.

  • 2.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe

    ZS2500 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS2500 is ideal for 2.5 GHz and lower oscilloscopes.

  • 1.5 GHz, 1 MΩ, 0.9 pF Active Probe

    ZS1500 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1500 is ideal for 1 GHz and lower oscilloscopes.

  • 1 GHz, 1 MΩ, 0.9 pF Active Probe

    ZS1000 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1000 is ideal for 200–600 MHz oscilloscopes.

  • Wattmeters

    WaveNode

    Monitor 4 sensors simultaneously for peak, Average power and coax SWR. Direct USB 2.0 full speed interface. Backlit LCD display for stand-alone operation- Your PC is optional. Oscilloscope and Spectrum Analysis of the RF Modulation- Observe IM and "Splatter" frequency components realtime. Complete system includes (1) sensor, WN-2 unit, AC power module and software on CDROM. Wide range of sensors cover 100 milliwatt to 8KW, 1.6 Mhz to 470 Mhz.

  • Exposure Level Tester

    ELT-400 - Narda Safety Test Solutions

    *Wide frequency range (1 Hz - 400 kHz)*Standard-compliant measurement*Acceptance measurements compliant with CE standard IEC/EN 62233 and Generic Standard IEC 62311*Limit value traces conforming to ICNIRP 1998, 2010 and EMF Directive 2013/35/EU*Real time measurement with RMS and peak detectors*External FFT signal analysis for determining the frequency components via three channel analog output (one channel for each spatial axis) e.g. with the aid of a digital oscilloscope.

  • Hand-Held Testers

    Qmax Test Technologies Pvt. Ltd.

    multifunction test instrument comprise of Single Channel Oscilloscope, High precision Digital Multimeter, Function Generator, LCR Meter and Frequency measurement functions . The compact and hand held size with re-chargeable battery makes it your ideal companion for the ideal for on-field operation. Measuring and testing just became easier and more affordable than ever. The high pixel LCD High Density Back-Lit Graphical display with live auto measure functions makes this tool more valuable in test and repair industry.

  • Test & Measurement Products

    Cole-Parmer Instrument

    We offer a broad range of test and measurement devices for your scientific, educational, industrial, and process applications. We carry the test and measurements tools you need to analyze, validate, and verify measurements in your electronic and mechanical systems, ensuring compliance to quality assurance and quality control programs. Our selection features portable and bench oscilloscopes, multimeters (DMMs), clamp meters, megohmmeters, stroboscopes and tachometers, power transformers, along with precision meters for humidity, moisture, light, airflow, weather, and vibration.

  • Resonance Dip Meter

    NRM-2 - National RF, Inc

    National RF’s Resonance Dip Meter is a test instrument used to determine the resonant frequency of a tuned circuit or resonant network, such as an antenna system. In addition, the unit may function as an RF detector, or a secondary frequency source. The instrument is analogous to the older vacuum tube “grid dip meter,” once popular in every electronic laboratory or radio station. Unique to this updated version is a buffered output that may drive a digital frequency counter for exact measurement of resonant frequency, or connected to an oscilloscope to be used as an RF detector and waveform/modulation monitor.

  • 2.92mm to ProBus Probe Adapter

    L2.92A-PBUS - Teledyne LeCroy

    The Teledyne LeCroy LabMaster 10 Zi oscilloscope utilizes precision 2.92mm input connectors to achieve up to 36GHz of input bandwidth. But some applications may require the use of lower-bandwidth probes for performance and cost reasons.The L2.92A-PBUS adapter converts the 2.92mm interface to a ProBus interface. This brings the benefits of a wider selection of probes to the LabMaster 10 Zi from high-impedance ZS active probes to the high-bandwidth WaveLink differential probing system. Full probe power and control is provided through a built-in LEMO interface.

  • Optical Modulation Analyzer

    OMA - Quantifi Photonics Inc.

    In partnership with Tektronix, we bring you a high-performing and flexible OMA system that will meet your requirements today and into the future.With the market-leading performance of Quantifi Photonics’ IQRX coherent receiver and the scalable architecture of Tektronix’s high-performing oscilloscopes, you’ll get the most out of your investment. Use the stack as a single 70GHz OMA system, or use it as four independent oscilloscopes.Whether you are working with 100G coherent transceivers or 1 Terabit long haul communication systems, our OMA can be configured to suit your exact requirements.

Get Help