Showing results: 931 - 945 of 1612 items found.
-
Datexel
Signal IsolatorsDatexel manufacture a large range of Signal Isolators. The DAT511 is a loop powered isolator with 3000 V galvanic isolation between the input and output. It is a 2 wire device so there is no external wiring. The DAT511H is similar but is Hart compatible. The DAT4035 is a universal input signal (Thermocouples, RTD's, mV, Volts, mA, resistance and potentiometers) conditioner with 2000 V isolation between the input and output and it is PC programmable. It is a 2 wire loop powered device. The DAT4135 is similar but it is a 4 wire device so it has the ability to boost the output or provide a voltage output.
-
Datexel
The DAT4530 can convert any process signal (Thermocouples, RTD, mV, Voltage, mA Resistance and Potentiometer) to a voltage or current output (4-20mA, 0-20mA or 0-10V). Each output can be different and it also has a built in limit alarm which is an SPST relay. The DAT4530 is PC programmable with the aid of the Prodat programmer and the Datasoft software which is available from the Datexel down load page. The DAT4530 is also programmable with the aid of 3 DIP switches which can be found on the side of the DAT4530. There is full isolation between the input, power supply, limit alarm output and two outputs.
-
Monarch Instrument
The Track-It™ Temperature Data Logger is a battery powered stand alone compact data logger that records up to 64,000 samples of temperature data. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.
-
Model JI-300 -
Jupiter Instruments
The JI-300 is a versatile, easy to use PC hosted adapter used to drive I2C communicationsto/from a target device. The desktop unit can be configured to interface a variety of I2Cnetworks. Bus parameters such as clock frequency, duty-cycle, setup and hold times, busvoltage, and pull-up resistor values can be varied. JI-300''s diagnostic features including"excessive clock-stretch", "bus-not-free", and "bus contention" monitoring, as well as statusreporting at the conclusion of each message transaction simplifies I2C trouble-shooting. AWindows software application manages the setup and control of the instrument.Communications and unit power is provided via a USB 2.0 connection.
-
Model AWG30D -
Aplab Limited
- 4.3′ High Resolution TFT LCD Display- Two Independent Channels Output, Same Characteristic- 1μHz Frequency Resolution for whole range- 120 MSa/s Sampling Rate, 14 Bits Vertical Resolution- 5 Standard Waveforms, 50 Built-in and 5 User-defined Arbitrary Waveforms- FM, AM, PM, PWM, Sum, FSK, BPSK and SUM Modulation, Sweep and Burst Function- Channel Coupling and Combine Features On CHB- Build in 350MHz Frequency Counter- Arbitrary Waveform Edit PC Software- Standard Interface: USB Host, USB Device and RS-232
-
DSC-L600 -
Thermtest Instruments
The Differential Scanning Calorimeter (DSC-L600) is a powerful thermal analysis instrument that measures the heat flow of a sample as a function of time or temperature. The DSC-L600 has been designed to be a cost-effective instrument that is well suited for research or QC applications. The instrument communicates with the PC via a RS232/USB connection. The specially designed heat flux plate has demonstrated more than twice the sensitivity than other heat flow type DSC’s on the market. The reproducibility is excellent, and the noise level is virtually unnoticeable due to a precision high gain, low noise differential amplifier
-
Smartech Inc.
- Magnetic induction (F) method is used to measure the thickness of non-magnetic coating on ferrous metal- Eddy current (N) method is used to measure the thickness of non-conducting coating on non-ferrous materials- Automatic recognition of substrate- Automatic selection of measuring methods- 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)- Upper-lower limit setting and sound alarm- Data output to printer or PC by RS232 cable- 500 readings can be stored- 2 measuring modes: continuous / single- 2 stop ways: Manual/automatic
-
BB60C -
Signal Hound
The BB60C streams 140 MB/sec of digitized RF to your PC utilizing USB 3.0, providing an instantaneous bandwidth of 27 MHz, and sweep speeds of 24 GHz/sec. The BB60C has significantly improved performance compared to the BB60A. The BB60C has improved spurious-free dynamic range (SFDR) by 20 dB, flattened the noise floor and band transitions by more than 8 dB, and extended operating temperatures from -40ºC to +65ºC (Option 1). The BB60C also adds new functionality in the form of configurable I/Q streaming bandwidths which will be retroactively available on the BB60A.
-
Rotronic Measurement Solutions
A temperature transmitter is an electrical instrument that interfaces a temperature sensor (e.g. thermocouple, RTD, or thermistor) to a measurement or control device (e.g. PLC, DCS, PC, loop controller, data logger, display, recorder, etc.). Typically, temperature transmitters isolate, amplify, filter noise, linearize, and convert the input signal from the sensor then send (transmit) a standardized output signal to the control device. Common electrical output signals used in manufacturing plants are 4-20mA or 0-10V DC ranges. For example, 4mA could represent 0°C and 20mA means 100°C.
-
DN2.828-04 -
Spectrum Instrumentation
The hybridNETBOX DN2.82x series internally consists of a Digitizer and an AWG that can run together or independently. That allows simultaneous data generation and data acquisition for stimulus-response tests, ATE applications, MIMO applications or closed-loop applications. Used independently, the digitizer can acquire test data in the field and the AWG can replay this test data in lab. The hybridNETBOX offers 14/16 bit resolution and is available with digitizer sampling rates of up to 500 MS/s and AWG sampling rates of up to 1.25 GS/s. The hybridNETBOX can be installed anywhere in the company LAN and can be remotely controlled from a host PC.
-
DN2.822-02 -
Spectrum Instrumentation
The hybridNETBOX DN2.82x series internally consists of a Digitizer and an AWG that can run together or independently. That allows simultaneous data generation and data acquisition for stimulus-response tests, ATE applications, MIMO applications or closed-loop applications. Used independently, the digitizer can acquire test data in the field and the AWG can replay this test data in lab. The hybridNETBOX offers 14/16 bit resolution and is available with digitizer sampling rates of up to 500 MS/s and AWG sampling rates of up to 1.25 GS/s. The hybridNETBOX can be installed anywhere in the company LAN and can be remotely controlled from a host PC.
-
DN2.825-04 -
Spectrum Instrumentation
The hybridNETBOX DN2.82x series internally consists of a Digitizer and an AWG that can run together or independently. That allows simultaneous data generation and data acquisition for stimulus-response tests, ATE applications, MIMO applications or closed-loop applications. Used independently, the digitizer can acquire test data in the field and the AWG can replay this test data in lab. The hybridNETBOX offers 14/16 bit resolution and is available with digitizer sampling rates of up to 500 MS/s and AWG sampling rates of up to 1.25 GS/s. The hybridNETBOX can be installed anywhere in the company LAN and can be remotely controlled from a host PC.
-
DN2.827-04 -
Spectrum Instrumentation
The hybridNETBOX DN2.82x series internally consists of a Digitizer and an AWG that can run together or independently. That allows simultaneous data generation and data acquisition for stimulus-response tests, ATE applications, MIMO applications or closed-loop applications. Used independently, the digitizer can acquire test data in the field and the AWG can replay this test data in lab. The hybridNETBOX offers 14/16 bit resolution and is available with digitizer sampling rates of up to 500 MS/s and AWG sampling rates of up to 1.25 GS/s. The hybridNETBOX can be installed anywhere in the company LAN and can be remotely controlled from a host PC.
-
DN2.827-02 -
Spectrum Instrumentation
The hybridNETBOX DN2.82x series internally consists of a Digitizer and an AWG that can run together or independently. That allows simultaneous data generation and data acquisition for stimulus-response tests, ATE applications, MIMO applications or closed-loop applications. Used independently, the digitizer can acquire test data in the field and the AWG can replay this test data in lab. The hybridNETBOX offers 14/16 bit resolution and is available with digitizer sampling rates of up to 500 MS/s and AWG sampling rates of up to 1.25 GS/s. The hybridNETBOX can be installed anywhere in the company LAN and can be remotely controlled from a host PC.
-
DN2.825-02 -
Spectrum Instrumentation
The hybridNETBOX DN2.82x series internally consists of a Digitizer and an AWG that can run together or independently. That allows simultaneous data generation and data acquisition for stimulus-response tests, ATE applications, MIMO applications or closed-loop applications. Used independently, the digitizer can acquire test data in the field and the AWG can replay this test data in lab. The hybridNETBOX offers 14/16 bit resolution and is available with digitizer sampling rates of up to 500 MS/s and AWG sampling rates of up to 1.25 GS/s. The hybridNETBOX can be installed anywhere in the company LAN and can be remotely controlled from a host PC.