Showing results: 31 - 37 of 37 items found.
-
NI
The C Series PROFINET Interface Module provides two PROFINET interface ports that enable you to reliably connect programmable logic controllers (PLCs), I/O, sensors, and drives over long distances in industrial environments. PROFINET is an application protocol that uses familiar concepts from PROFIBUS that are implemented on the physical layer of Ethernet. The C Series PROFINET Interface Module includes NI-PROFINET driver software for human machine interface (HMI) and supervisory control and data acquisition (SCADA) applications. You can perform PROFINET device automated test using these interfaces.
-
BKM93KIO -
Techna-Tool Inc.
Clockwise and/or counter-clockwise rotation of the wand is programmable allowing an optimum adaptation to the machine.The scanning intensity is adjustable in 8 steps. Even rotating drills with small diameters can be checked.The scanning results are display as "OK" or "KO" and signalled by LEDs on the front side of the device.The PROFIBUS is a standard Sub-D 9 pin connection; the USB connection is a USB-mini plug / type B and meets the 2.0 specification.Three digital inputs serve to activate the functions "Teach-in" to learn the position to be scanned, "Start" to initialize the scanning process and "Configurable" for receiving a stop command.Two digital outputs provide the signals for the message "OK" or "KO".The relay contacts are configurable as N/C or N/O connections. They can be set as momentary (valid with start or timed) or latching.Convenient configuration software for programming and setting of tool data is available at no cost.
-
Agilent Technologies
Agilent's full range of active and passive vacuum gauges and gauge controllers from atmosphere to UHV/XHV allow you to precisely and reliably control and measure vacuum. We offer Thermocouple (TC), Bayard Alpert (BA), Pirani, Inverted Magnetron (IMG), and Hot Filament (HFIG) gauges. Our gauge controllers are compatible with both Agilent and competitors' gauges and can handle up to 12 channels. Agilent controllers come with several communication interfaces including Profibus, ethernet, and RS-232/485 (other interfaces may be available upon request). There is also the option of a portable gauge controller (HGC-536).
-
AEM-DRA -
Chuan Sheng Electronics Co., Ltd.
The AEM-DRA series has 2 independent and isolated main circuit inputs , can use for different power system.Up to 24 single phase or 8 three-phase circuits, programmable from push buttons with LCM display panel, or using Adtek program software through RS485 communication port.Hardware standard built in a RS485 Modbus communication port , 2 Digital inputs, 4 Relay outputs, LCM and 2 MB flash for data-logging.Optional second communication port for Ethernet, ProfiBus ,LonWorks ,BACnet and Zigbee solutions.Din rail mounting , compact and easy installation, programming through computer and push buttons easy to use.
-
ViTec Co. Ltd
Our automated scanning system is based on smart 3D cameras SICK Ruler E 600. Information about the wheel profile from the camera via a high-speed Gigabit Ethernet interface is sent to a dedicated computer for processing, detecting and recognizing the alphanumeric sequence applied to a specific section of the wheel. Synchronization with the rotation system is carried out by means of a high-precision encoder, with the conveyor system - via the Profibus DP interface. The complex is designed to scan wheels of various standard sizes and allows with a high resolution (tenths of a millimeter), without readjustment, to read numbers from wheels at a radius of 100 to 600 mm in 45 seconds.
-
BKM91 -
Techna-Tool Inc.
Clockwise and/or counter-clockwise rotation of the wand is programmable allowing an optimum adaptation to the machine.The scanning intensity is adjustable in 8 steps. Even rotating drills with small diameters can be checked.The scanning results are display as "OK" or "KO" and signaled by LEDs on the front side of the device.The PROFIBUS is a standard Sub-D 9 pin connection; the USB connection is a USB-mini plug / type B and meets the 2.0 specification.Three digital inputs serve to activate the functions "Teach-in" to learn the position to be scanned, "Start" to initialize the scanning process and "Configurable" for receiving a stop command.Two digital outputs provide the signals for the message "OK" or "KO".The relay contacts are configurable as N/C or N/O connections. They can be set as momentary (valid with start or timed) or latching.Convenient configuration software for programming and setting of tool data is available at no cost.Mini USB for PC connection3 digital control inputs (positive or negative logic) Start and teach signal One configurable input2 relay outputs selectable as N/C or N/O contact Signal all clear message ("OK") Signal error message ("KO") Scanner connection4 LEDs for status display Opening for top hat plug for optional connection to I/O extension module Din rail mounting
-
BKM91PN -
Techna-Tool Inc.
Clockwise and/or counter-clockwise rotation of the wand is programmable allowing an optimum adaptation to the machine.The scanning intensity is adjustable in 8 steps. Even rotating drills with small diameters can be checked.The scanning results are display as "OK" or "KO" and signaled by LEDs on the front side of the device.The PROFIBUS is a standard Sub-D 9 pin connection; the USB connection is a USB-mini plug / type B and meets the 2.0 specification.Three digital inputs serve to activate the functions "Teach-in" to learn the position to be scanned, "Start" to initialize the scanning process and "Configurable" for receiving a stop command.Two digital outputs provide the signals for the message "OK" or "KO".The relay contacts are configurable as N/C or N/O connections. They can be set as momentary (valid with start or timed) or latching.Convenient configuration software for programming and setting of tool data is available at no cost.Mini USB for PC connection3 digital control inputs (positive or negative logic) Start and teach signal One configurable input2 relay outputs selectable as N/C or N/O contact Signal all clear message ("OK") Signal error message ("KO") Scanner connection4 LEDs for status display Opening for top hat plug for optional connection to I/O extension module Din rail mounting