Showing results: 1111 - 1125 of 1489 items found.
-
778572-34 -
NI
256-Crosspoint, 1-Wire PXI Matrix Switch Module—The PXI‑2534 is a high-density 8x32 PXI matrix switch module built to serve high‑channel‑count automated test systems. Featuring solid-state relays (SSRs), the PXI‑2534 offers unlimited mechanical lifetime and the ability to route 55 W simultaneously on all channels. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
M9120A -
Keysight Technologies
The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
M9165A -
Keysight Technologies
M9165A 2X8 PXIe switch matrix, 300 KHz to 6.5 GHz is a full cross-bar switch matrix that provide a switch based multiport VNA solution.
-
M9164C -
Keysight Technologies
M9164C 2X16 PXIe switch matrix, 300 KHz to 18 GHz is a full cross-bar switch matrix that provide a switch based multiport VNA solution.
-
M9165B -
Keysight Technologies
M9165B 2X8 PXIe switch matrix, 300 KHz to 9 GHz is a full cross-bar switch matrix that provides a switch based multiport VNA solution.
-
778572-40 -
NI
350 MHz, 8x9 PXI RF Matrix Switch Module—The PXI‑2540 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXI‑2540 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers.
-
780587-41 -
NI
PXIe, 300 MHz, 8x12 PXI RF Matrix Switch Module—The PXIe‑2541 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXIe‑2541 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers. For higher channel count applications, you can connect multiple PXIe‑2541 modules together to create switching matrices of 8x24, 8x36, and larger.
-
60-510-002 -
Pickering Interfaces Ltd.
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.
-
781420-13 -
NI
4x21, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2813 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
34931A -
Keysight Technologies
The Keysight 34931A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 configurations 64 2-wire cross-points Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter Latching armature relays 300 V, 1 A switch; 2 A carry current
-
M9122A -
Keysight Technologies
The M9122A is an 8x32 full crosspoint switch matrix offering high-voltage switching in a high-density PXI module. This module allows for higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This module is configured with a common ground. The durable armature switches are capable of switching up to 100Vrms, with up to 60W of power. The 8-wide bus can be used to route signals between your instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
778572-41 -
NI
300 MHz, 8x12 PXI RF Matrix Switch Module—The PXI‑2541 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXI‑2541 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers. For higher channel count applications, you can connect multiple PXI‑2541 modules together to create switching matrices of 8x24, 8x36, and larger.
-
40-562A-021-10X32 -
Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
40-560B-021-138X16 -
Pickering Interfaces Ltd.
The 40-560B-021-138x16 is an ultra high density matrix module and is part of our range PXI BRIC matrices. They are available in 2, 4, 8 or 12-slot sizes to suit high performance PXI switching requirements and is constructed using instrumentation quality reed relays.
-
40-560B-021-138X8 -
Pickering Interfaces Ltd.
The 40-560B-021-138x8 is an ultra high density matrix module and is part of our range PXI BRIC matrices. They are available in 2, 4, 8 or 12-slot sizes to suit high performance PXI switching requirements and is constructed using instrumentation quality reed relays.