40-830-103 -
Pickering Interfaces Ltd.
The 40-830 is a 75 RF Switch available with 3 or 6 separate SPDT relays in a single PXI slot. Both versions have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks have been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The design of the 40-830 minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
M9122A -
Keysight Technologies
The M9122A is an 8x32 full crosspoint switch matrix offering high-voltage switching in a high-density PXI module. This module allows for higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This module is configured with a common ground. The durable armature switches are capable of switching up to 100Vrms, with up to 60W of power. The 8-wide bus can be used to route signals between your instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
40-137-001 -
Pickering Interfaces Ltd.
These PXI Power Relay Modules are suitable for applications requiring power relay switching with high density. This version features 5A current and voltage to 110VDC/250VAC, they are configured as Single Pole Single Throw (SPST). Connections are made via front panel mounted 37 or 78-pin D-Type connector. Along with this 16 x SPST, 5A version, the range also includes a 39 x SPST, 2A version and a 32x SPST version - go to Also in the Range above to learn more. Typical applications will be found in Automotive Test, Aerospace Test and Power Cell Test applications.
-
40-667A-012 -
Pickering Interfaces Ltd.
The 40-667A-012 is a single 6-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-666B-012 -
Pickering Interfaces Ltd.
The 40-666B-012 is a single 6-channel 10A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-667C-011 -
Pickering Interfaces Ltd.
The 40-667C-011 is a dual 3-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-667A-011 -
Pickering Interfaces Ltd.
The 40-667A-011 is a dual 3-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-667C-012 -
Pickering Interfaces Ltd.
The 40-667C-012 is a single 6-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-666A-012 -
Pickering Interfaces Ltd.
The 40-666A-012 is a single 6-channel 10A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-666B-011 -
Pickering Interfaces Ltd.
The 40-666B-011 is a dual 3-channel 10A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-666A-011 -
Pickering Interfaces Ltd.
The 40-666A-011 is a dual 3-channel 10A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-667B-011 -
Pickering Interfaces Ltd.
The 40-667B-011 is a dual 3-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-667B-012 -
Pickering Interfaces Ltd.
The 40-667B-012 is a single 6-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
GX6196 -
Marvin Test Solutions, Inc.
The GX6196 is a 6U PXI switch and control board that can be used to create custom switching, signal conditioning, or specific UUT control interfaces. The board provides 96, 2 pole, form A relays, 8 digital I/O lines, and a serial digital interface. All of these resources are available via (5) inter-board connectors which interface to the user defined daughter / mezzanine board. The mezzanine board provides all connections to the unit under test (UUT) via two 78 pin D-sub connectors. The GX6196 is supplied with a front panel which accepts (2) 78 pin D-sub connectors.
-
783638-01 -
NI
12.5 Gbps, 8-Channel PXI High-Speed Serial Instrument—The PXIe‑6591 is designed for engineers who need to validate, interface through, and test serial protocols. It includes a Xilinx Kintex‑7 FPGA to implement various high-speed serial protocols, and it is programmable with the LabVIEW FPGA Module for maximum application-specific customization and reuse. The PXIe‑6591 takes advantage of FPGA multigigabit transceivers and up to eight TX and RX lanes. In addition to high-speed serial lanes, the PXIe‑6591 features digital I/O signals that support multiple logic families with per line, per cycle direction control.