Showing results: 556 - 570 of 5651 items found.
-
GX3702 -
Marvin Test Solutions, Inc.
The GX3702 is a user configurable, FPGA-based, 3U PXI card which offers 160 digital I/O signals which can be configured for single-ended or differential interfaces. The card employs the Altera Stratix III FPGA, which can support SerDes data rates up to 1.2 Gb/s, digital I/O clock rates of 700 MHz, and features over 45,000 logic elements and 1.836 Kb of memory. The GX3702 is supplied with an integral expansion board providing access to the FPGA's 160 I/Os and is pin for pin compatible with the NI PXI 7813R and 7811R FPGA cards . Alternatively, users can design their own custom expansion cards for specific applications - eliminating the need for additional external boards which are cumbersome and physically difficult to integrate into a test system. The design of the FPGA is done by using Altera's free Quartus II Web Edition tool set. Once the user has compiled the FPGA design, the configuration file can be loaded into the FPGA directly or via an on-board EEPROM.
-
40-513-021-S -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
40-513-021 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
Pickering Interfaces Ltd.
Our PXI high-density general purpose switches provide an ideal solution for applications requiring dense arrays of uncommitted relays.All reed relay modules use high-quality sputtered ruthenium relays that exhibit excellent contact performance under low and medium level switching conditions. Do you have a general purpose application that requires high power handling? We also have electro-mechanical modules that are ideal for just these situations.
-
40-510-021-S -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
40-510-021 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
40-661-001 -
Pickering Interfaces Ltd.
The 40-661 is a single pole PXI power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
40-161-102 -
Pickering Interfaces Ltd.
This40-161 range of PXI power relay modules is available with achoice of 16 x SPST, 12 x SPST, 10 x SPST, 12 x SPDT and 6 x SPDT power relays, for switching loads up to 16A at250VAC. These Power Relay Modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. The 40-161 is ideal for switching up to 16A in both AC and DC applications.
-
40-161-002 -
Pickering Interfaces Ltd.
This40-161 range of PXI power relay modules is available with achoice of 16 x SPST, 12 x SPST, 10 x SPST, 12 x SPDT and 6 x SPDT power relays, for switching loads up to 16A at250VAC. These Power Relay Modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. The 40-161 is ideal for switching up to 16A in both AC and DC applications.
-
Pickering Interfaces Ltd.
Pickering's PXI Differential Fault Insertion Switch Modules support multiple channels of two-wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to externally applied fault conditions. *Two module types are available: Two wire fault insertion module suitable for CAN Bus and FlexRay.*High bandwidth two wire fault insertion module suitable for Gigabit Ethernet, AFDX and BroadR-Reach.
-
40-161-101 -
Pickering Interfaces Ltd.
This40-161 range of PXI power relay modules is available with achoice of 16 x SPST, 12 x SPST, 10 x SPST, 12 x SPDT and 6 x SPDT power relays, for switching loads up to 16A at250VAC. These Power Relay Modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. The 40-161 is ideal for switching up to 16A in both AC and DC applications.
-
41-650-012 -
Pickering Interfaces Ltd.
The 41-650 is a 5 channel voltage amplifier ideal for increasing the output voltage from other PXI modules, enabling users to easily generate the signal voltages commonly required in applications such as automotive test. Each amplifier can be independently programmed to a gain of 1, 2, 5, 10 or 20, enabling it to be used with modules with low output voltage capability. Inputs and outputs can be provided either on SMB connectors or on a D Type connector to suite the user’s wiring system.
-
40-860-512-M -
Pickering Interfaces Ltd.
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
40-860-222-M -
Pickering Interfaces Ltd.
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
40-860-522-M -
Pickering Interfaces Ltd.
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.