Showing results: 646 - 660 of 5678 items found.
-
40-614B-014 -
Pickering Interfaces Ltd.
This 2-bank, 4-channel, 16-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614-012 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-002 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-001 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-651-001 -
Pickering Interfaces Ltd.
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel 4-bank. 11-channel 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
40-614B-003 -
Pickering Interfaces Ltd.
This 8-bank, 16-channel, 1-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614-019 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614B-008 -
Pickering Interfaces Ltd.
This 4-bank, 8-channel, 4-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614-003 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614B-018 -
Pickering Interfaces Ltd.
This 1-bank, 16-channel, 8-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614B-012 -
Pickering Interfaces Ltd.
This 2-bank, 16-channel, 4-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614C-020 -
Pickering Interfaces Ltd.
This 1-bank, 4-channel, 32 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614-007 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-651-003 -
Pickering Interfaces Ltd.
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
40-614-016 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.