Filter Results By:

Products

Applications

Manufacturers

Particle

subatomic or minute speck of matter

See Also: Nanoparticle, Airborne Particle, Particle Accelerator, Particle Counters, Particle Detection


Showing recent results 166 - 180 of 259 products found.

  • Automatically Differentiate Cyanobacteria

    FlowCam® Cyano - Fluid Imaging Technologies

    Based on proven FlowCam® technology, the new FlowCam Cyano automatically identifies cyanobacteria from other algae and particles in aquatic samples. Using a patent-pending combination of excitation wavelength, phycocyanin fluorescence measurement and image recognition software, the system automates what used to be done manually using microscopy. After differentiating the cyanobacteria form the other algae in the sample, VisualSpreadsheet and Advanced Classifier software can be used to further characterize the specific types of all algae found in the sample.

  • Cement, Coal & Mineral Test & Analytical Solutions

    Thermo Fisher Scientific Inc.

    Keep coal, cement, or mineral processing operations running efficiently, safely, and profitably. Thermo Scientific™ cross-belt online analyzers for cement and coal reduce process upsets and increase throughput with minute-by-minute composition analysis of ores and concentrates. Additionally, Thermo Scientific elemental and particle size analyzers for mineral beneficiation and flotation plants—when integrated with our sampling and analysis solutions—help you to increase the efficiency of your process.

  • Civil Engineering Testing Machine

    AGGREGATE/SAND - Tinius Olsen

    Aggregates that are flaky and/or elongated will often lower the work ability of a concrete mix, and may also affect long term durability. In bituminous mixtures, flaky aggregates make for a harsh mix and may also crack and break up during compacting by rolling. The flakiness of aggregate is determined by measuring the thickness of individual particles. We offer both a thickness gauge and length gauge to check flakiness index and elongation index of the aggregate respectively.

  • Combustion Diagnostics

    Dantec Dynamics A/S

    Dantec Dynamics offers a wide range of measurement solutions for diagnostics throughout all stages of the combustion process, providing information about: Combustion radicals by Laser-Induced Fluorescence (LIF), Fuel distribution by Laser-Induced Fluorescence (LIF), Flame development by Time-resolved Laser-Induced Fluorescence (TR LIF), Flame temperature by Rayleigh Thermometry, Soot volume fraction by Laser-Induced Incandescence (LII), Flow velocity fields by Particle Image Velocimetry (PIV)

  • Combustion Check Gas Analyzer

    KM 5410 - KUSAM-MECO

    * Hand-pump with filter to isolate dirt and particles.* Thermocouple offset adjustment ±3°C (6°F).* Automatic power off battery saver.* 2 channel display(LCD).* Display Back-Light.* Analyzer Directly Measures: Flue Gas Oxygen Content in % and Flue Gas Temperature in °F or °C* Analyzer Computes: When the measured oxygen level is below 17.9%, Flue Gas Carbon Dioxide content in %, , Excess Air in %(0 to 400%), Flue Natural Gas/Oil #2/Propane in %

  • Monte-Carlo Simulator for Ultra-high Vacuum Systems

    Molflow - MolFlow+

    Molflow+ allows you to calculate the pressure in an arbitrarily complex geometry when ultra-high vacuum condition is met. The name comes from molecular flow, the condition when the mean free path of molecules is so long compared to the geometry size that collisions can be neglected. In this case, particles fly independently, which makes this physics particularly suitable for Monte Carlo simulations.

  • Measurement System

    KOERZIMAT® 1.097 HCJ - Institut Dr. Foerster GmbH & Co. KG

    The KOERZIMAT 1.097 HCJ measuring system by FOERSTER facilitates the accurate, automatic, and fast measurement of the coercitivity HcJ. The largely geometry-free measurement is particularly suitable for testing samples with complex shapes. The applications of the Koerzimat include the control of the sintering level and particle size of hard metals and the quality control of metallic powders for the production of magnets and hard metals. The unit can also be used for monitoring the quality of the annealing and the mechanical stress state of soft-magnetic components (SMC) and for controlling electromechanical components in the electronics, automotive, computer, and clock sectors.

  • Ingress Protection – Dripping Water Tests (IPX1 and IPX2)

    Keystone Compliance

    Ingress protection testing tests the level of protection an enclosure provides against intrusions. One such set of ingress protection tests is called the dripping water test. These tests are numbered IPX1 or IPX2. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of the dripping water ingress protection test, would always be either a 1 or a 2.

  • Ingress Protection: High-Temperature and High-Pressure Water Jets Tests (IPX9)

    Keystone Compliance

    Ingress protection testing tests the level of protection an enclosure provides against intrusions. One such set of ingress protection tests involves exposing the equipment under test (EUT), to high-pressure and high-temperature water jets. These tests are numbered IPX9. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of the high-pressure and high temperature water jets ingress protection test, would always be a 9.

  • Ingress Protection: Immersion Water Tests (IPX7 and IPX8)

    Keystone Compliance

    Ingress protection testing tests the level of protection an enclosure provides against intrusions. One such set of ingress protection tests involves immersing the equipment under test (EUT), in water. These tests are numbered IPX7 and IPX8. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of the immersion ingress protection test, would always be a 7 or an 8.

  • Ingress Protection: Spraying Water and Splashing Water (IPX3 & IPX4)

    Keystone Compliance

    Ingress protection testing tests the level of protection an enclosure provides against intrusions. Two such sets of ingress protection tests involve exposing the equipment under test (EUT), to spraying water and splashing water. These tests are numbered IPX3 and IPX4. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of spraying water, would always be a 3, and in the case of splashing water, would always be a 4.

  • Ingress Protection: Water Jets and Powerful Water Jets Tests (IPX5 & IPX6)

    Keystone Compliance

    Ingress protection testing tests the level of protection an enclosure provides against intrusions. Two such sets of ingress protection tests involve exposing the equipment under test (EUT), to water jets and powerful water jets. These tests are numbered IPX5 and IPX6. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of water jets, would always be a 5, and in the case of powerful water jets, would always be a 6.

  • Humidifier Vibrators

    Fuji Ceramics Corporation

    Ultrasonic energy generated from the piezoelectric elements will be larger. The center of the sound pressure is focused with certain directivity. The Power of the focused sound pressure, it lifts up the water surface, and arises the water column. Water film of water column tip is tearing, and then splashing the misty of fine particles to the air. This action is the atomization principle by ultrasonic. In the high-frequency and high-power, and it provides a dedicated vibrators having excellent durability.

  • Image Analyzers

    Morphologi Range - Malvern Panalytical Ltd

    Morphological imaging is fast becoming an essential technology in the laboratory toolkit for particle characterization.  The Morphologi 4 is a fully automated static image analysis system which provides a complete detailed description of the morphological properties of particulate materials.  The Morphologi 4-ID combines the same automated static image analysis with Raman spectroscopy in a single, integrated platform, providing component-specific morphological descriptions of chemical species within a blend.

  • Aerosol Neutralizer

    3077A - TSI Inc.

    Aerosol Neutralizer 3077A has five times the activity of the Model 3077. The 3077A is offered for general-purpose applications involving highly charged aerosols and low flow rates. It is supplied with our Model 3034 Scanning Mobility Particle Sizer™ (SMPS) spectrometer.Features and Benefits Radioactivity of 370 MBq Maximum flow rate of 5 L/min Kr-85 source