Showing results: 1006 - 1020 of 1575 items found.
-
515 -
Clarke-Hess Communications Research
The Model 515 High Accuracy AC Reference Generator fills a need for a relatively low cost and practical solution for supplying a reference excitation to typical LVDT and Synchro/Resolver transducers. The Model 515 has built-in load sensing which, in effect, yields "zero" output impedance and virtually eliminates the effects of fluctuating output loads. With up to 15 VA of output into loads with as much as 80 of phase shift, the Model 515 is ideally suited to driving inductive loads.
-
RFCT -
Textron Systems
Textron Systems’ Radio Frequency Cable Tester (RFCT) allows for on-site testing and maintenance for radio frequency (RF) transmission paths within a platform. Using preconfigured databases of sweep parameters and pass/fail criteria, the RFCT quickly determines the status of installed RF cables. The RFCT checks each cable’s performance characteristics to include voltage standing wave ratio (VSWR), insertion loss (IL), phase and phase matching. If a cable fails a test, the RFCT automatically determines the distance-to-fault (DTF). With its intuitive touchscreen-based user interface and lightweight, ruggedized packaging, the RFCT is the gold standard for operational-level RF cable testing.
-
85131G -
Keysight Technologies
The Keysight 85131G is a 53 cm (21 in) long1 semi-rigid cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss of 16 dB or better. Insertion loss is 0.3 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.8 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 4 inch radius. Stability1 of the Keysight 85131G is 0.06 dB and phase is 0.16o * f + 0.5o (where f is frequency in GHz).
-
85132F -
Keysight Technologies
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Shenzhen Graigar Technology Co.,Ltd.
This power analyzer is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50º of the harmonic waveform. The power analyser clamp is equipped with data logger.
-
Bofa Instrument & Equipment Co., Ltd
Energy meter is a new type of single phase electronic energy meters, which completely accords with international standard IEC61036. It can display energy consumption by stepping-motor counter or LCD. It features good reliability, small volume, light weight and convenient installation.
-
CZ20500 -
Aegis Pty. Ltd.
The CZ20500 Multi-Function electrical tester includes some of the latest advances in electrical testing, combining 5 instruments into 1! Insulation, Loop, Phase, RCD, and Voltage testing are all included in the one instrument, making your job of installation testing easier.
-
TB41 -
Calmet Smart Calibration Devices
The Calmet TB41 Four Position Meter Test Bench is used for calibration and simultaneously testing up to four single and three phase electromechanical and electronic acitve and reactive electricity meters with accuracy referenced to an internal reference meter (class 0.02% or 0.04%).
-
Weshine Electric Manufacturing Co., Ltd
Transformer K Factor, Power factors(PF)and displacement factors, Short-term voltage flicker, .Three phase unbalance (Current and Voltage), Waveform real-time display(4 channels voltage /4 channels current) True RMS values of voltages and currents
-
PN9000 -
Eastern-Optx
The PN9000 is a simple and fast Automatic Phase Noise Test System covering a very wide frequency range(2 MHz to 140 GHz). Its modular architecture allows optimum configuration, multiple measurement techniques and future growth in a compact instrument.
-
MegaPhase, llc
Our test & measurement cables provide customers with a competitive edge over ordinary cable designs by addressing three important criteria for testing electronic components and systems: phase stability, insertion loss stability and repeatable measurements for the cable’s useful life.
-
1255B -
Ametek Scientific Instruments
Using the single sine technique the 1255B provides precise measurement of gain and phase between any two points in a system. This fully digital technique is used to assess the performance of both simple and complex systems - electrochemical, materials, electronics, mechanical, and acoustic.
-
1180 -
The Eastern Specialty Company
The TESCO K-Base Test Board Adapter allow quick, convenient testing of self-contained K-Base meters on test boards designed for socket type meters. The K-Base Test Board Adapters are designed for single phase (Catalog No. 1180-2) and polyphase (Catalog No. 1180-4).
-
ALS Co., Ltd
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
64-VBF -
Viewpoint Systems, Inc
The 64-VBF 10th order Lowpass Filter is a dual channel filter with independent switch settable Cutoff Frequency (Fc). The filter has a linear phase DC accurate root raised cosine response. The unit’s differential inputs are built to withstand high DC over-voltages up to ±50 VDC and greater than ±100 V transients. Gain of the unit is 1 allowing for minimal insertion issues. The output can drive a high speed DAQ multiplexer with its fast settle and capacitive drive capability.