Showing results: 1081 - 1095 of 1575 items found.
-
Humiditest™ Complete System -
James Instruments Inc.
The James Instruments Humitest System allows the concrete practitioner to monitor and ensure that a new structure is dry enough to proceed with the next phase of construction. This is especially critical for concrete structures requiring a coating, carpeting or similar floor or covering treatment. Installing such treatments before the concrete is sufficiently dry will typically cause expensive failures in the covering treatment. The only accurate way to ensure that the concrete is sufficiently dry enough to safely avoid expensive re-work is via a bore hole humidity test system, such as the Humitest System
-
Ducommun Inc
Ducommun’s oscillator family includes FET based dielectric resonator oscillators (OFD), phase locked oscillators (OPL), Gunn diode based low cost Gunn oscillators (OGL), bias tuned Gunn oscillators (OGB), mechanically tuned oscillators (OGM), varactor tuned Gunn oscillators (OGV), injection locked Gunn oscillators (OGI) and Gunn oscillator bias regulators and modulators (OGR and OMR). In the mechanically tuned Gunn oscillator family, the ultra broadband series (OGF) delivers up to full waveguide tuning bandwidth.
-
Teledyne Defense Electronics
Teledyne Storm Microwave, an industry leader in providing advanced cable assemblies and interconnect products around the globe, has a long and proud heritage serving domestic and overseas defense and telecom markets since 1978.At Teledyne Storm, we manufacture our flexible and semi-rigid coax cable in-house leveraging the highest quality, state-of-the-art equipment and processes. Flexible cable assemblies through 50 GHz are engineered and stringently tested to meet the most demanding requirements for Low Loss, Phase Stability, Durability, and Miniaturization.
-
784197-01 -
NI
PXIe, 42 V, 2-Channel PXI Counter/Timer Module—The Astronics PXIe‑2461 is a high-performance counter/timer module that provides easy-to-use automatic measurement functions, including phase, pulse, peak, rise/fall time, time interval and ratio measurement, all with high resolution. It features nine digits per second resolution, programmable measurement timeout, and nine different arming modes. You can set the Astronics PXIe-2461 to measure timing and amplitude characteristics in one of two voltage ranges: ±5.1 V or ±42 V.
-
Optoplex Corporation
The integrated DQPSK receiver incorporates an optical phase demodulator (delay-line interferometer or DLI) with 2 pairs of balanced photo-diodes and 2 linear TIAs into a single butterfly package. Compared with the currently available discrete solution in which a separate DLI and a separate receiver are used, the integrated DQPSK receiver eliminates labor intensive fiber routing and coupling (between the DLI and the balanced receiver) as well as the skew control. Moreover, the integrated DQPSK receiver offers a smaller footprint suitable for today’s demanding high speed transponder applications.
-
SP-6103 -
Shanghai Powoo Industry Develop Group Limited
- Single phase energy meter test bench - auto-calibration system - accuracy class: 0.1/0.2 class - Standard CT; 0.01/0.02 - output voltage: 0-220V9240V option); range: 0-120% - fine adjustment: 0.01% - output current: 0-100A; (option for 200A)- fine adjustment: 0.0001A (min)
-
MGKS -
Holding Informtest
The MGKS vector signal generator is designed to reproduce arbitrary waveforms, as well as sinusoidal signals with amplitude, frequency, phase modulation or without modulation. The generator can be used for research, tuning and testing of systems and devices used in radio electronics, automation, computing and measuring technology, instrument making.
-
Baltic Scientific Instruments, Ltd
X-ray spectrometers based on Si detectors with liquid nitrogen cooling, Peltier and electric machine cooling. The spectrometers are applied in the various systems for element analysis: X-ray fluorescent; electron probe; with alpha and beta excitation etc, as well as for the precision diffractometry in the devices of structural and phase analysis.
-
TG23P -
Aircraft Development Industries cc
The model TG23P is an entirely solid state digital 3 Phase, 2 pole, Tachometer Generator Simulator. There are no motors, strobe lights or moving parts in the unit which makes it ideal for testing electro-mechanical type Tachometers, Percent RPM Indicators, Dual and Triple Tachometer indicators
-
Langer EMV-Technik GmbH
Used for EMI suppression in printed circuit boards during the development phase. The developer can use the E1 set to quickly identify the causes of burst and ESD interference. This allows the developer to design suitable measures to solve the causes of the interference. It can also be used to test the effectiveness of the measures taken.
-
Keysight Technologies
Keysight Technologies provides MMIC frequency dividers and prescalers ideal for high-frequency communications, microwave instrumentation, and electronic warfare (EW) radar system applications. These devices operate from DC to 16 GHz and provide a large input power sensitivity window and low phase noise.
-
Dewesoft d.o.o.
E-Mobility - eDrive, and Electric Vehicle TestingAdvanced and easy to use solutions for complete electric and hybrid vehicle testing in the development, validation and production phase. One-stop solutions for electric motor and inverter testing, battery and battery charge testing, combustion analysis, hydrogen engine testing and more.
-
DG4000 Series -
Rigol Technologies Inc.
DG4000 series multi-function signal generator with functions of function generator, arbitrary waveform generator, pulse generator, harmonic generator, analog / digital modulator, frequency meter, etc.; all models of this series have two channels with identical functions and phase adjustable between channels.
-
PT-LabCar -
ETAS GmbH
PT-LABCAR is an open and scalable Hardware-in-the-Loop (HiL) system. It is designed for open- and closed-loop testing of ECUs specifically in the powertrain application domain. The system can be used to run automated regression tests for the release of software variants as well as for the validation of control and diagnostic functions in early phases of ECU development.
-
Kuhne electronic GmbH
First approach is to generate the high frequency directly, at the fundamental, using an oscillatortuned on the desired frequency. Few sensitive issues appears here due to high working frequency as, stability, jitter, phase noise, pulling, pushing, low output power, and cost of the active component to meet the performances