Filter Results By:

Products

Applications

Manufacturers

Phase

the difference between two features of a waveform, measured in any of multiple manners (distance, time, angle, wavelength, etc.)

See Also: Phasing, Phase Standards, Phase Meters, Phase Angle, 3 Phase, Time


Showing results: 1126 - 1140 of 1575 items found.

  • Universal Counters

    SC-7217A / SC-7215A - IWATSU Electronic Co., Ltd.

    The SC-7217A / SC-7215A universal counters provide full capabilities including frequency, period, time interval, pulse width, phase, frequency ratio, duty cycle, event accumulation and peak voltage measuring, with simple operation. They are suitable for R&D and technical training as a basic measuring instrument as well as for production/inspection lines.

  • Semi-automatic Three-phase kWh Meter Test Bench

    SY8310 - Hong Kong Songyang Industrial Ltd.

    The new SY8310 series semi-automatic three phase energy meter test board, designed according to International Standard, is a newly developed ideal measuring equipment for energy meters. The equipment can be operated easily through test board button to preset directly all data of meter under test and test process.

  • Power Quality Meter

    PQMII - GE Digital Energy

    The PQM II is an ideal choice when continuous monitoring of a three phase system is required. It provides metering for current, voltage, real and reactive power, energy use, cost of power, power factor and frequency. Programmable setpoints and 4 assignable output relays allow control functions to be added for specific applications.

  • Pulsed Injection Locked IMPATT Amplifiers

    Insight Product Company

    Pulsed injection locked amplifier incorporates IMPATT diode, ferrite input/output isolators, circulators, and pulse modulator. Only DC power supply, RF input signal, and external trigger signal are required to operate amplifier. Output phase noise parameters are very close to the noise parameters of the input RF signal.

  • Fiber Optic Modem

    VCH-608 - VREMYA-CH JS Company

    The VCH-608 fiber optic modem is designed to receive and transmit via a fiber optic communication line (FOCL) signals of frequency and time standards (TSV) :- pulse signals 1 Hz (1 PPS) with delay compensation,- harmonic electrical signals with a nominal value frequency 100 MHz with phase instability compensation.

  • Two-Pole Voltage Tester

    P-4 - Sonel S.A.

    Sonel P-4 is reliable, particularly durable and safe 2-pole testers, which enable testing voltage, circuit continuity and phase sequence. It has been designed for use in extreme conditions both in industry and commercial applications. Advanced technology, a high level of safety and user-friendliness are the key features of the P-line voltage testers.

  • MXG Signal Generators

    Keysight Technologies

    On the path to better performance, the Keysight's MXG signal generators are fine-tuned signal sources in R&D measurements. Whether you’re pushing for a linear RF chain or an optimized link budget, the analog and vector MXG models deliver the performance and capabilities you need: phase noise, ACPR, channel coding, and more.

  • Analogue ELCB Tester

    1810 EL - Standard Electric Works Co., Ltd

    ● Taut Band movement.● Simple operation.● Wiring check.● Robust.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● No battery required.● Sense automatically 50 or 60 Hz.● Current injected in phase with the voltage.● Other voltage optional (110V).

  • PXIe-5654, 10 GHz or 20 GHz RF Signal Generator

    783126-01 - NI

    The PXIe‑5654 features an ideal combination of exceptional phase noise and frequency tuning time. These features address applications such as blocker test/receiver desensitization, high-performance intermodulation distortion measurements, and various electronic warfare applications. The PXIe‑5654 is designed to meet the challenging requirements of RFIC characterization, satellite test, and radar applications.

  • Drop Volume Tensiometer

    DVT50 - KRÜSS GmbH

    The effect of a surfactant as an emulsifier is based on the fact that it reduces the interfacial tension between phases which do not easily mix. As surfactants need a certain time to do this, the effect of an emulsifier depends on the mixing dynamics. With our Drop Volume Tensiometer – DVT50, you can measure the speed with which emulsifiers produce their effect and reduce the interfacial tension. The DVT50 spectrum ranges from very fast to very slow processes. This enables the dynamic mixing behavior as well as the stability of an emulsion at close to the quiescent state to be determined in a single measurement. The results of the measurement help to precisely optimize and dose surfactants for emulsions.

  • Earth Leakage Breaker And Residual Current Device

    IGR Series - Jaeshininfo Co. Ltd

    IGR Leakage Current Analyzer is invented as the world first, and also can measure Insulation Resistance (MO) without power cut-off. This patented instrument can analyze leakage current, and display Igr(resistive), Igc(capacitive), and Io(vector sum), Ground Insulation Resistance, and the phase angle between voltage and current. (IGR ELB) - Operates due to Igr. - Properly-operating in spite of IGC in digital era. ( Not tripping on UPS load and Harmonics and noise area) - Possible to go down Igr for safety of people and animals. - Possible to manufacture high sensitive ELB. - Possible to prevent fire from electric leakage current.

  • ECU Calibration

    Accurate Technologies Inc.

    Designing an Electronic Control Unit (ECU) is only the beginning. The features in ECUs, such as Powertrain Control Units, are quickly becoming more complex and offering more features. Thousands of variables are now provided for the engineer to modify during the in-vehicle calibration phase, and fine tuning them is as complicated as it is critical. Calibration tools significantly impact the efficiency and effectiveness of the ECU development process. These tools are typically comprised of PC-based software to perform the adjustment of the variables and an ECU hardware interface to provide the connection of the software to the controller. Teams must be able to measure and time-align relationships of inputs and outputs and make real-time modifications.

  • High Frequency Current Transformer

    HFCT Ø 140mm - Techimp HQ S.r.L

    Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).

  • PCIe Direct Digital Synthesizer

    Furaxa, Inc.

    These devices provide two synchronized DDS-based RF channels on a single PCI card. With fine frequency, amplitude and phase control the Synth1000 products enable a number of advanced applications at a fraction of the cost of conventional equipment. In addition to two analog outputs the Synth1000, up to 4 separate profiles may be dynamically selected using externally supplied TTL signals for low-latency triggered operation such as PSK, FSK, and triggered sweep operation. Software support for Windows 8, 7, Vista, Windows XP and Linux is included. LabVIEW Labview source code available. For detailed specifications, please refer to the Synth1000 Manual.

  • RF Signal Generators

    Salicon Nano Technology

    As Rigol's RF first signal source, the DSG3000 series offers standard AM/FM/ØM analog modulation, as well as options for I/Q modulation and I/Q baseband output. The instrument is available with maximum frequencies of either 3 GHz or 6 GHz. Featuring a high signal purity with phase noise measuring <-110dBc/Hz@20kHz (typical) and a wide output range of -130dBm to +13dBm, the DSG3000 RF signal generator has standard pulse modulation with an on/off ratio of up to 80dB, with optional pulse train generator available. The DSG3000 series also has an amplitude accuracy of <0.5dB (typical).

Get Help