Filter Results By:
Products
Applications
Manufacturers
Photomultipliers
multiply current of light ADC resulting in greater sensitivity.
-
product
Photomultiplier
PMT-101
Photo Multiplier Tube with a range of 185 - 700 nm. Has a built in power supply. Built in low noise amplifier with a gain of x1 and x100.
-
product
Photomultiplier
PMT-102
Photo Multiplier Tube with a range of 185 - 875 nm. Has a built in power supply. Built in low noise amplifier with a gain of x1 and x100.
-
product
Microscope Photomultiplier Photometers
HORIBA's microscope photometers are ideal for any lab wishing to quantitate light intensity from a sample on a microscope stage. Initially designed for the most demanding low light level fluorescence kinetics of labeled mammalian cells, these photometers are also just as well suited for mineral analysis or transmission studies.
-
product
Photomultiplier Tube (PMT) Bases
Scintillation detectors produce light as they absorb energy, and these light flashes result in the release of a proportionate number of photoelectrons at the cathode of a photomultiplier tube (PMT). Each of the ORTEC Photomultiplier Tube Bases is designed to accommodate a particular type of PMT to distribute the operating voltages to all its elements, and to derive signals from it.
-
product
Intelligent Silicon Photomultiplier Tube
i-Spector family
i-Spector is a all-in-one detector and electronics instrument based on a SiPM area (18×18 mm2, 24×24 mm2 or 30×30 mm2), possibly coupled to a scintillation crystal suitable for the chosen application. The i-Spector integrates in a compact tube-like mechanics the detection stage, frontend electronics, an integrated power supply for SiPM biasing and, eventually, a digital chain to process onboard the incoming data. The i-Spector can be controlled via Ethernet and/or wireless communication based on LoRa standard.
-
product
Sulfur Dioxide Analyzer(SO2)
AQMS-500
Analyzer applies UV fluorescence technology with the photomultiplier tube (PMT) to measure SO.
-
product
Current Preamplifier
1641
The Model 1641 Current Preamplifier is a simple low cost wideband gain block for use with photomultipliers
-
product
Single Channel Detectors
Teledyne Princeton Instruments
Single channel detectors are used with IsoPlane, SpectraPro and TriVista spectrometers, enabling efficient operation from UV to IR. These include three photomultiplier tubes, two silicon detectors, plus InGaAs, PbS, InSb, HgCdTe and infrared detectors.
-
product
Photodiodes
Avalanche
Similar to photomultipliers, avalanche photodiodes are used to detect extremely weak light intensities. Si APDs are used in the wavelength range from 250 to 1100 nm, and InGaAs is used as semiconductor material in APDs for the wavelength range from 1100 to 1700 nm.
-
product
Avalanche Photodiodes
Similar to photomultipliers, avalanche photodiodes are used to detect extremely weak light intensities. Si APDs are used in the wavelength range from 250 to 1100 nm, and InGaAs is used as semiconductor material in APDs for the wavelength range from 1100 to 1700 nm.
-
product
Avalanche Photodiodes
Similar to photomultipliers, avalanche photodiodes are used to detect extremely weak light intensities. Si APDs are used in the wavelength range from 250 to 1100 nm, and InGaAs is used as semiconductor material in APDs for the wavelength range from 1100 to 1700 nm.
-
product
BSE Detection
SLIM
SLIM™ is an innovative design for under-the-column BSE detection.SLIM™ puts El-Mul’s ScintiFast™ together with a segmented, shaped light guide and Silicon Photomultipliers (SiPM) to create a fast, sensitive, segmented and compact BSE detector for e-beam tools.
-
product
Thermal Neutron Detector
TN15
The TN15 high sensitivity thermal neutron detector utilizes a state-of-the-art silicon photomultiplier (SiPM) and offers world-leading specification in a compact form. The TN15 surpasses the performance of a 100mm long 13mm3 He tube at 4 atmospheres and does not need cooling but operates at room temperature.
-
product
Transimpediance Amplifiers
The UDT TRAMP products are transimpedance amplifier (current-to-voltage) instruments that provide a low input impedance to accurately measure the short circuit current of phototransducers such as silicon and germanium photodetectors, vacuum photodiodes and photomultiplier tubes. The range includes the economically priced TRAMP, and for ultra precision and accuracy, the TIA-3000.
-
product
350 MHz Preamplifier
SIM914
Stanford Research Systems, Inc.
The SIM914 350 MHz Preamplifier contains two wide-bandwidth, DC-coupled amplifiers, each with a gain of 5 (14 dB). Its fast rise time, low noise and excellent DC accuracy make it an ideal instrument for amplifying signals like those from photomultiplier tubes and photodiodes.
-
product
Electronic Instruments
The ORTEC range of modular electronics includes instruments in NIM formats as well as other modular instruments, such as photomultiplier bases, preamplifiers and other accessories. ORTEC also offers modular instruments for pulse height spectroscopy, fast timing, counting, high voltage power supplies and other special functions.
-
product
Optical Sensors
module is basically comprised of a photomultiplier tube to convert light into electrical signals, a high-voltage power supply circuit, and a voltage divider circuit to distribute the optimum voltage to each dynode, all assembled into a single compact case. In addition to these basic PMT modules, Hamamatsu also provides modules having various additional functions such as signal processing, cooling and interface to PC.
-
product
Digitizer
743 Family
The 743 is the Switched Capacitor Digitizer family, based on the SAMLONG chip and developed in collaboration with CEA/IRFU, with a good compromise between high sampling frequency (3.2GS/s) and channel density. It can record very fast signals from scintillators coupled to PMTs, Silicon Photomultipliers, APD, Diamond detectors and others, and save them with high efficiency and precision for advanced timing analysis.
-
product
Thermo-Electrically Cooled Dual Mode Analog/Photon Counting Photmultiplier Tube (PMT)
CoolOne
For spectroscopy and microscopy experiments in the UV/Vis/NIR region of the spectrum, a photomultiplier tube (PMT) is the ideal detector for quantitative low light level measurements. A PMT is extremely sensitive, with very wide dynamic range so it can also measure high levels of light. PMT’s are also very fast so rapid changes in optical signals can be reliably monitored. As a practical matter, PMT’s are durable, long-lived, and economical.
-
product
Digitizer
761 Family
The 761 is the family of CAEN Waveform Digitizer with the highest sampling rate Flash ADC (10 bit @ 4GS/s). It can record fast signals from fast organic, inorganic and liquid scintillators coupled to PMTs or Silicon Photomultipliers, Diamond detectors and others, and save them with high efficiency and precision for advanced timing analysis. The acquisition can be externally vetoed/gated. Multiple boards can be synchronized to build up complex systems.
-
product
Digitizer
720 Family
The 720 is a family of CAEN Waveform Digitizer able to perform basic waveform recording and run online advanced algorithms (DPP) of charge integration and pulse shape discrimination. Data is read by a Flash ADC, 12-bit resolution and 250 MS/s sampling rate, which is well suited for mid-fast signals as the ones coming from liquid or inorganic scintillators coupled to PMTs or Silicon Photomultipliers. In the waveform recording mode, algorithms of zero suppression are also implemented to reduce the data throughput.
-
product
2 Channel 10 bit 4GS/s Digitizer
V1761
The V1761 comes in a VME form factor with 2 input channels. The communication to and from the board is provided through VMEBus and Optical Link interfaces. It can record fast signals from fast organic, inorganic and liquid scintillators coupled to PMTs or Silicon Photomultipliers, Diamond detectors and others, and save them with high efficiency and precision for offline advanced timing analysis.
-
product
Charge Sensitive Preamplifier-Discriminator
A101
Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.
-
product
Digital MCA Tube Base For Gamma-Ray Spectroscopy
Gamma Stream Family
CAEN Gamma stream is a compact and portable system for gamma ray spectroscopy with scintillation detectors, which provides an active Multi-Channel Analyzer (MCA) integrated in a 14-pin photo-multiplier tube (PMT) base. Gamma stream fully integrates in a stand-alone device the high voltage to bias the PMT, the preamplifier to shape the signal from detector, and the MCA for a complete Pulse Height Analysis online.
-
product
Rapid Automated Modular Microscope
RAMM
Applied Scientific Instrumentation
*Featuring automated high-speed XY stages, precision piezo & motorized Z focusing, and a wide range of scanning options.*Configurable with infinity-corrected optics, dichroic filter cubes, multi-wavelength excitation and emission filterwheels, shutters, and detectors including cameras and photomultipliers.*Auto-focus, focus stabilization, tracker, and robotic specimen loader available.*Arrangement provides a solid platform for high throughput screening, genetic sequencing, experimental research, and much more.*Designed for flexible cost-effective OEM development using high quality high MTBF components to reduce cost and increase customer satisfaction.
-
product
Full spectrum direct reading spectrometer
TY-9000
Wuxi Tianmu Instrument Technology Co., Ltd.
The TY-9000 full-spectrum direct-reading spectrometer desktop spectrometer adopts international standard design and manufacturing process technology, adopts all-digital technology, replaces the huge photomultiplier tube (PMT) simulation technology, synchronizes with international spectrometer technology, adopts vacuum light chamber design And Full digital excitation source, leading CCD detector, high-speed data readout system, the instrument has high performance, very low detection line, long-term stability and repeatability.
-
product
Scintillator Detectors
SIGMA Family
Our SIGMA range of CsI(Tl) thallium activated caesium iodide scintillator radiation detector products replaces conventional photomultiplier technology with state of the art SiPMs. These gamma-ray detectors offer up to 32.8 cm3 of detection volume, delivered in a package providing significant benefits in cost, size, weight, power consumption and temperature stability. Robust, small and light SIGMA caesium iodide scintillator radiation detectors are perfect for radiation detection in the field and in the lab. Clients have flown them on drones, built them into large detector arrays and other devices. If you need fast detection in an easy to use package this is what you need.
-
product
Digitizer
742 Family
The 742 is the Switched Capacitor Digitizer family, based on the DRS4 chip by PSI, with the highest sampling frequency (5GS/s) and channel density. It can record very fast signals from scintillators coupled to PMTs, Silicon Photomultipliers, APD, Diamond detectors and others, and save them with high efficiency and precision for advanced timing analysis. The 742 family has an additional channel (two channels in case of VME boards) which can be used as time reference for time of fight measurements. The resolution of this kind of measurements can reach up to 50 ps.
-
product
Detectors
Designed and manufactured by Becker & Hickl - bh offers a wide range of detector types as photomultiplier tubes (PMC), hybrid photo detectors (HPM), single-photon avalanche diodes (SPAD) as well as multi-channel- and multi-spectral detectors. The detection range covers the wavelengths from UV to the NIR and time resolutions spanning from tens of ps to hundreds of ps suitable for anti-bunching, FCS, FLIM, PLIM and other applications. bh guarantee that their TCSPC modules work with any photon counting detector and reach the fastest possible IRF width.Choose your detection now:
-
product
Trace-Level Chemiluminescence NO/NO2/NOx Analyzer
Model T200U
Teledyne Advanced Pollution Instrumentation
The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.