Filter Results By:

Products

Applications

Manufacturers

Showing results: 226 - 240 of 318 items found.

  • Current Transformer Analyzer/Tester

    GF106T - Beijing GFUVE Electronics Co.,Ltd.

    It is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

  • Digital RCD Tester

    8012 EL - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Extra large LCD(78 × 67mm).● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Auto power off.● Auto off and off override.● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.●Frequency measurement indication.

  • Multi-Purpose Digital H. V. Phasing Meter

    MDP-50K - Standard Electric Works Co., Ltd

    ● AC 50kV and DC 50kV measurement with direct reading.● 4000-count LCD.● Input impedance : 400 Mohm● Auto-ranging : AC : 4.000kV / 40.00kV / 50.0kV DC : 4.000kV / 40.00kV / 50.0kV● MDP-50K must be connected with an approved hot stick, such as HS-175, HS-120.● Polarity indication : Positive / Negative● Backlight function.● Auto power off.● Power source : 1.5V(AA) alkaline battery × 2.● Low battery indication(Multi-level). ● Protection class : IP66

  • Multi-purpose Tester

    DEL-101 - Standard Electric Works Co., Ltd

    ● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.

  • Dual Trace Oscilloscope

    KM-20-10 / KM-20-20 - Kusam Electrical Industries Limited

    • Dual channels / dual traces, X-Y mode• 6” display, high brightness oscilloscope tube• High sensitivity triggering, upto 1mV / division clearer displaythan ordinary oscilloscope.• TV synchronous separation circuit to observe stable TV signal.• Triggering mode : AUTO / NORM / AV-V / AV-H• Vertical : ALT / CHOP / ADDX-x10 / Y-x5; Polarity reversal; CH1 Sync output• Power Supply : AC 220V ADN (110V optional)

  • Universal Multichannel System up to 3.5 kV

    CAEN S.p.A.

    - From 12 to 48 independently controllable High Voltage channels- 0 ÷ 3.5 kV output voltage- Maximum Current 3.5 mA- Either Radiall Multipin or SHV connectors- Available with either positive or negative polarity- Up to 10 nA / 500 pA current set / monitor resolution- Up to 5 mV voltage set / monitor resolution- Very Low ripple, down to < 5 mVpp- 2 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down - TRIP parameter- Current generator operation in over current condition- Specific design for High Altitudes 0÷5000 m (A7030 only)

  • Electrostatic Field Meter Kit

    PFK-100B - Prostat Corporation

    - Measure range & polarity of electrostatic fields in 1 volt or 10 volts increments- Charges from zero to over 1000 volts in less than 5 seconds- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Use with a datalogger to record measurements & create reports- Compatible with the Autoanalysis System- Accuracy of ± 5%- Battery Operated

  • Avionics Data Bus Tester

    Distributed CORVUS - DragoonITCN

    Distributed CORVUS works in conjunction with CORVUS-300 to isolate bus anomalies and fault resolution. The Transmit unit, C-9235-TX, sends 1553 like data pattern through a bus stub and coupler to the Receive unit, C-9235-RX, on another stub. This will measure insertion loss, possible bit errors and correct polarity. The Receive unit can also be used to give a digital scope representation of the active data bus showing signal quality and peak to peak amplitude.

  • Multi - Purpose Digital High Voltage Phasing Meter

    Model KM-MPS-50K - Kusam Electrical Industries Limited

    • AC 50kV and DC 50kV measurement with direct reading.• 4000-count LCD.• Input impedance : 400 Mohm• Auto-ranging : AC : 4.000kV / 40.00kV / 50.0kV, DC : 4.000kV / 40.00kV / 50.0kV• KM 50K must be connected with an approved hot stick (Optional).• Check phases are "in-phase" or "out of phase".• Polarity indication : Positive / Negative• Backlight function.• Auto power off.• Power source : 1.5V(AA) alkaline battery × 2.• Low battery indication(Multi-level).

  • Digital I / O modules

    Acery Technologies

    The 34950A module has 64-bit bi-directional lines and can be configured with 8 8-bit digital I / O channels with handshaking capability. Each 8-bit channel has programmable polarity and a threshold of up to 5V. The memory can be used to generate or capture digital patterns up to 10 MHz. It provides seven configurable handshaking protocols for a wide range of applications. In addition, two counter / totalizer channels can be used to compute events, frequency, period, duty cycle, accumulation, and pulse width.

  • Bench Power Supply, Adjustable, Fixed, 3 Output, 0 V, 32 V, 0 A, 5 A

    72-13610 - Tenma

    *Triple channel linear DC power supply*Dual channel adjustable & one channel fixed*Constant current & constant voltage operation*Forced ventilation & temperature cooling system*LED digital tube display shows voltage and current simultaneously*Low ripple & low noise, output on/off control*Overload and reverse polarity protection*115VAC/230VAC (50Hz/60Hz) AC input voltage and 0.01% high regulation*12-month limited warranty *view Terms & Conditions for details

  • Bench Power Supply, Adjustable, Fixed, 3 Output, 0 V, 32 V, 0 A, 3 A

    72-13600 - Tenma

    *Triple channel linear DC power supply*Dual channel adjustable & one channel fixed*Constant current & constant voltage operation*Forced ventilation & temperature cooling system*LED digital tube display shows voltage and current simultaneously*Low ripple & low noise, output on/off control*Overload and reverse polarity protection*115VAC/230VAC (50Hz/60Hz) AC input voltage and 0.01% high regulation*12-month limited warranty *view Terms & Conditions for details

  • Portable Electrical Management Systems

    EMS-PT30C - Progressive Industries

    Progressive Industries Portable Electrical Management Systems (EMS) offer quick and easy RV electrical protection. A true plug-and-play application with no installation required. You will feel secure with multi-mode surge, voltage, polarity, and lost/open neutral protection. Each unit includes a digital display, scrolling continuously through the power source information: voltage(s), current frequency, error code, and previous error code (if applicable). Additionally, the computer is driven by state of the art microprocessors.

  • RV Power Protection with Surge

    EMS-PT50C - Progressive Industries

    Progressive Industries Portable Electrical Management Systems (EMS) offer quick and easy RV electrical protection. A true plug-and-play application with no installation required. You will feel secure with multi-mode surge, voltage, polarity, and lost/open neutral protection. Each unit includes a digital display, scrolling continuously through the power source information: voltage(s), current frequency, error code, and previous error code (if applicable). Additionally, the computer is driven by state of the art microprocessors.

  • Current Transformer Testers

    Vanguard Instruments Company, Inc.

    Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface

Get Help