Filter Results By:

Products

Applications

Manufacturers

Power

a measure of watts in electricity and radiant energy in optics.

See Also: Power Quality


Showing results: 9121 - 9135 of 11090 items found.

  • Advanced Solar Charge Controller with 48V/96V/120V/192VV/240V/360V

    SDC360V-100A - Zhejiang Sandi Electric Co., Ltd

    The solar charge controller is the intelligent devicewith integration of controlling . It has good running performance with LCD display and convenient operation. Also have multi protection functions such as over-charge, over-discharge protection, and pole-confusion protection for storage battery. The controller is adopted PWM charging mode. It has day and night two type working mode with high reliable and safe operation, high efficiency, long service life functions.Technical Features:The solar charge controller adopts industrial-grade chips to ensure the stable feature of controllerExcellent EMC designHigh efficient PWM charging technology which has three charging stages (buck charging stage, equalize charging stage and float charging stage), and improves battery storage efficiency and charging efficiency.Advanced battery activation technology which increases battery lifetime 30% at least and improves the system performanceThe 120a solar charge controller adopts imported IGBT power module or MOSFET as electronic switch which can improve the stable performance of controller. There aren’t any mechanical switches in the systemLCD will display the system status and working parametersParameters setting flexiblyUsers can parallel connect lots of the controller is a systemFully enclosed duct design and high speed fan for cooling making the controller working in a variety of harsh environmentsDC output function (Optional)Standard Modbus protocol for RS-485 communication to extend the communication distance (Optional)The 120a solar charge controller will alarm when the system status is abnormalNew SOC method displays battery power accuratelyWith power generation statistics function to facilitate the view of power generation of daily, month and totalThere is temperature compensation function which will compensate the temperature according to different battery typeThe 120a solar charge controller adopts graphical dot-matrix LCD and 4 buttons as HMI for full menu and easy operationRTC time functionWall mounting type is easy for installation

  • 76kWh Lithium Battery 384V 200AHSolar Energy Storage LiFePO4 battery System

    SPVLI-76KWH - Zhejiang Sandi Electric Co., Ltd

    SANDI ESS lithium battery system is composed of lithium battery modules, BMS system, PV charge controller, AC/DC Charger, central control unit CCU, temperature detector, integrated structure and other parts; the solar panels in the system are battery storage and power for output; BMS module completes the detection and control of voltage, current, temperature, SOC, SOH and charging and discharging related parameters of power battery pack; PV controller and inverter realize bidirectional AC/DC function to meet the charging and discharging conversion demand of power battery pack; each detector is used to monitor the ambient temperature in real time to ensure the safety of the system.Features1. Standardized components, modular architecture, easy for expansion2. High energy density, small footprint, short construction period, strong environmental adaptability3. Battery module within the layered stack design, with more than 10 years of long design life4. Long Cycle Life LiFePO4 Lithium ion Battery system from 20KWH-500KWH optional5. The use of international advanced Mitsubishi IPM module and intelligent power module, with high power fast adjustment capability6. BMS battery management system with SOC automatic calibration and high current active balance function, combined with the perfect operation control and management strategies to achieve accurate and efficient management7. The combination of software and hardware protection, with alarm protection and automatic diagnostic functions, improve the protection strategy to ensure safe and efficient operation of the system8. Product communicates with the monitoring platform in real time through RS232, CAN communication interface, and reports various records in time to ensure real-time monitoring of the battery pack of the monitoring platform9. PV charge controller adopts three charging stages (buck charging, equalize charging and float charging) which can maximize the utilization of PV modules and batteries10. Colorful LCD display all module working information and statusSpecificationModel SPVLI-76.8KWHType of cell LiFePO4 (Lithium iron phosphate)Battery configuration 3.2V 200AH 120PCSRated capacity (KWH) 76.8kwhNominal capacity (AH) 200AHNominal voltage (VDC) 384VOperating voltage range (VDC) 312-438VRecommended Charge Voltage (VDC) 420VRecommended discharge cutoff voltage (VDC) 360VRecommended charge current(A) 100AMax Charge Current (A) 200ARecommended discharge current (A) 100AMax Discharge Current (A) 200ACharge temperature range 1~45℃Discharge temperature range -10~45℃Solar Charge Controller InputMaximum. Input voltage of solar array(Vdc) <750VdcBattery system voltage 384VDCMaximum power of solar array 40KWMaximum charge current(A) 100AEqualization charging voltage (Vdc) 426VEqualize charging recovery voltage (Vdc) 405.6VOver voltage disconnect voltage (Vdc) 438VOver voltage recovery (Vdc) 432VWorking temperature -20~50℃Protection level IP20Communication interface CAN2.0, BMSDisplay 5" LCD, EnglishCooling system Fan coolingWorking Altitude (m) ≤3000mReference Weight (Kg) 920KgReference size (W*D*H mm) 900*1100*1700mm

  • Dielectric Breakdown Voltage and Dielectric Strength

    ASTM D149 - National Technical Systems

    This test method covers procedures for the determination of dielectric strength of solid insulating materials at commercial power frequencies, under specified conditions. Unless otherwise specified, the tests shall be made at 60 Hz. However, this test method is suitable for use at any frequency from 25 to 800 Hz. At frequencies above 800 Hz, dielectric heating is a potential problem. This test method is intended to be used in conjunction with any ASTM standard or other document that refers to this test method. References to this document need to specify the particular options to be used. It is suitable for use at various temperatures, and in any suitable gaseous or liquid surrounding medium. This test method is not intended for measuring the dielectric strength of materials that are fluid under the conditions of test. This test method is not intended for use in determining intrinsic dielectric strength, direct-voltage dielectric strength, or thermal failure under electrical stress (see Test Method ASTM D3151). This test method is most commonly used to determine the dielectric breakdown voltage through the thickness of a test specimen (puncture). It is also suitable for use to determine dielectric breakdown voltage along the interface between a solid specimen and a gaseous or liquid surrounding medium (flashover). This test method is similar to IEC Publication 243-1. All procedures in this method are included in IEC 243-1. Differences between this method and IEC 243-1 are largely editorial. Note: The above information is taken directly from the test method Scope published in ASTM D149.

  • Online UPS, Rackmount & Tower – 4.5kVA To 10kVA

    FN2 Series - Falcon Electric, Inc

    *Advanced DSP technology. The FN2 Online UPS features advanced Digital Signal Processing (DSP) technology with a unity output power factor. It also offers scalability and N+1 redundancy.*Versatile options. – Power Distribution Unit (PDU) with or without Maintenance Bypass Switch (MBS)– Extended battery banks*User-friendly LCD display. The FN2 has an easy-to-use display to monitor the UPS and battery status.*Extended battery banks. The hot-swappable battery banks are easily expandable for minutes to hours of extra battery runtime.*Advanced communications. The FN2’s software supports unattended shutdown and UPS management. An optional SNMP/HTTP agent board is available.*Falcon – recognized for quality and reliability. Falcon Electric is a recognized authority in online UPS solutions. Our technical expertise assures you find the right solution – the first time.

  • 1U Rackmount Network Appliance Platform With LGA1150 Socket Intel® Xeon® E3/Core™ Family Processor, Intel® C226 And Up To 24 LANs

    NA570 - Axiomtek Co., Ltd.

    NA570 1U rackmount Network Security Platform, supports the 4th generation Intel® Xeon® E3 / Core™ processor family, formerly codenamed "Haswell". NA570 offers greatly improved performance and reduced power consumption base on the new Intel architecture marked improvements in power efficiency and performance. The system supports up to 32GB DDR3 1600 non-ECC / ECC (only NA570) memory. NA570 support 4 pairs of LAN Bypass function. Bypass ports allow users to experience uninterrupted network traffic even if a single in-line appliance hangs or sudden shutdown. Expandable LAN Modules via the PCIe 3.0, support up to 24 GbE ports, or up to 4 ports at 10GbE, and a future upgrade to 40GbE, port density and optional networking ports to suit your demands.

  • 3.6 GS/sec Ultra Wideband RF/IF Extreme 1/2 ATR Recorder

    Talon RTX 2589 - Pentek, Inc.

    - Rugged 1/2 ATR MIL-spec chassis- Designed for harsh mechanical and thermal environments- Environmentally sealed- Internally conduction-cooled- Fully sealed for RF emissions with EMI power line filter- MIL-STD circular connectors- Compact and lightweight design - 22 lb (10kg)- Ideal for UAVs, military vehicles, aircraft pods and outdoor environments- Capable of recording RF/IF frequencies to 2.8 GHz- Ultra Wideband recording with 3.6 GHz 12-bit A/D- Selectable 1.8 GHz dual channel mode- Up to 61 TB of solid state storage in removable QuickPac- Sustained real-time record rates up to 4 GB/s- 12 to 28 VDC power supply- Optional GPS receiver for precise time and position stamping- SystemFlow API, GUI and Signal Viewer analysis tools- Optional telnet remote connection to recorder

  • Electromagnetic Radiation Tester

    Model KM 196 - Kusam Electrical Industries Limited

    • Unit : Electric Field : V/m; Magnetic Field : mT• Precision : Electric Field : 1V/m; Magnetic Field : 0.01 mT• Range : Electric Field : 1V/m ~ 1999V/m.• Magnetic Field : 0.01 mT ~ 19.99 mT• Alarm Threshold : Electric Field : 40V/m, Magnetic Field : 0.4 mT• Reading Display : 3½ Digit Digital LCD display with Backlight.• Frequency Range : 5Hz ~ 3500MHZ• Sampling Time : About 0.4 second.• Measuring Mode : Dual Mode• Overload Alert : “1” appears on LCD• Sound & Light Alarm• Data Hold function.• Auto Power Off.• Average & Peak measurement.• Low Battery Indication.• Operating Temperature & Humidity : 0°C ~ 50°C; below 80%RH.• Power battery : 9V Battery.• Dimension : 63.6 x 31 x 125.8mm• Weight : Approx. 146g.

  • Compact Automatic Voltage Regulating Relay With Built- In TPI

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Compact Automatic Voltage Regulating Relays

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Automatic Voltage Regulating Relay- Standard Model

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Digital Ior Leakage Current Clamp Tester

    MCL-400IR+ - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).

  • Battery Hydrometers

    Exponential Power

    Exponential Power introduced the first digital battery hydrometer to the U.S. stationary battery market in 1988. For over 30 years, Exponential Power has sold and serviced thousands of hydrometers and continues to provide the newest technologies in battery maintenance equipment today. Hydrometers (density meters) measure the specific gravity of a battery’s electrolyte. Based on the specific gravity, the user can determine the state of charge of the battery. Retaining these hydrometer readings and data over time is recommended by IEEE as part of any Battery Maintenance Program. Digital hydrometers are commonly used in utilities, telecommunications, industrial, food and beverage, petrochemical and other applications. In contrast to the old bulb-style hydrometers of the past, our digital hydrometers provide accurate recording, storage and transfer of battery data to a PC -- eliminating hours of hand recording and entering data. As a result, time spent on battery maintenance is reduced significantly.

  • RF Front-End ICs

    Analog Devices Inc.

    Analog Devices offers RF Front-End ICs for phased array antenna solutions. These RF Front-End ICsare placed right at the antenna element and can quickly switch between transmit and receive functions in radar applications. The power amplifier on the transmit side is highly efficient operating in short pulse durations. The low noise amplifier on the receive side has a low noise figure with high linearity so that it won’t distort the incoming return signal. The RF Front-End IC also incorporates a high performance switch to toggle between the transmit and receive paths. Highly integrated planar phased array antennae need small form factor solutions, and Analog Devices has integrated the switch, low noise amplifier, and power amplifier into a small surface mount package as well as the decoupling capacitors, providing an optimal solution.

  • Medical Modulators

    Teledyne e2v

    Te;edyne e2v offers a range of compact modulator systems based around its patented solid-state switching technology. High power pulsed systems are developed for radar and for linear accelerators used in industrial, scientific and medical applications.The compact modulator is a direct switching unit, designed to drive either our microwave tubes or those from other manufacturers. The high voltage modulators and semiconductor switches provide a real proven alternative to conventional "line and hard valve type" modulator technology. Using innovative assemblies of solid-state switches, together with compatible power supplies and energy storage units, gives a significant improvement in pulse shape and quality. A flexible control system gives the ability to remotely vary the pulse parameters on a pulse-to-pulse basis. These features make the units ideal for systems where precise energy control is essential.

  • Optical Chopper

    Edmund Optics Inc.

    These high stability variable frequency optical choppers each include a set of chemically blackened photoetched chopping discs. The mini chopper is an excellent choice for applications requiring a compact package. The chopping discs come in a variety of slot apertures and allow operation. Beam diameter is limited to 0.75mm when using the 200-slot disc and 1.0mm when using the 40 slot mini disc. The easy-to-interchange blades are made of non-magnetic, half hard brass and can be used in combination. Chopping frequency is set by adjusting a ten-turn dial or by applying an external DC voltage to the BNC input. Reference output is a TTL pulse and is in-phase with chopping action. The 5 digit led display gives a direct read-out of the chopping frequency. Power: 90-130V or 180-260V; 50/60Hz; 12VA max. Power supply included. Choppers are often used together with lock-in amplifiers.